Naturewater NW-PR, NW-PR305 Filter User manual

  • Hello! I'm your chat assistant, and I've reviewed the operation manual for the naturewater NW-PR series water filter models 51107, 51108, and 51109. This document provides instructions on installation, filter cartridge replacement, and maintenance. I'm ready to answer your questions about the filter system, including filter functions, connections, and operation.
  • What is the service life of the PP filter cartridge?
    How often should the granulated carbon filter (UDF) be replaced?
    What does the activated carbon afterfilter T33B do?
Operation Manual
NW-PR Filter
51107, 51108, 51109
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.
https://www.naturewater.eu Item 51107–51109 Page 2
03 2022-1
The information contained in this document may alter at any time without previous notice. It is prohibited
to copy or spread any parts of this document in any way without prior written allowance. All rights re-
served.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing
from you.
Send an e-mail to:
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany
Do you wish to pick goods up? Our pick-up address is:
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany
To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously or
placing your order via the webshop.
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
To return orders for exchange, repair, or other purposes, please use the following address. Attention!
To allow for a smooth execution of your complaint or return, it is important to contact our customer
service team before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
https://www.naturewater.eu Item 51107–51109 Page 3
03 2022-1
Introduction
Thank you for purchasing this quality product. To minimise the risk of injury we urge that our clients
take some basic safety precautions when using this device. Please read the operation instruc-
tions carefully and make sure you have understood its content.
Keep these operation instructions safe.
Parts and installation
A
Water supply connection
B
Shut-off valve
C
Sediment filter cartridge PP with 60 mm outer diameter for 5 µ
D
Activated carbon block with 68 mm outer diameter for 10 µ (CTO)
E
Granulated carbon filter with 72 mm outer diameter (UDF)
F
Activated carbon afterfilter (T33 A)
G
Activated carbon afterfilter (T33B)
H
Water tap
https://www.naturewater.eu Item 51107–51109 Page 4
03 2022-1
Mounting the water tap
On top of the worktop
Under the worktop
To a wall
Pressure-reducing valve
PP tube
Hexagon nut
Tube closure
Fitting
Water-tap on work-
top
Quick cou-
pling, connec-
tion with PE
hose
Quick coupling,
disconnection
from PE hose
JACO fitting, con-
necting a PE hose
Connecting the plastic hose with a connector
Trim a plastic hose according to previous measurement.
Insert the plastic hose into the hexagon nut.
Set the white hose plug in the end fitting of the white plastic hose, press it into the hose by hand
or using a tool.
Place the plastic hose into the connector.
Tightly screw the hexagon nut.
https://www.naturewater.eu Item 51107–51109 Page 5
03 2022-1
Connecting the plastic hose with a quick coupling
Trim a plastic hose according to previous measurement.
Deeply slide the plastic hose into the connector.
Disconnecting the plastic hose from the quick coupling
Remove the small piece.
Press on the round piece until it touches the main body of the quick coupling.
Move off the plastic hose.
Open the three housings, set the three filter cartridge types, PP, CTO, and UDF, into the housings and
seize them (clean the CTO filter and the UDF Filter before setting them into their housings). Then con-
nect the activated carbon afterfilters T33 A and T33B to the third filtering step.
The other areas require a PE hose for connecting.
Attach the short three-way valve and the spherical valve to the water tap.
Filter cartridges and their functions
Filter cartridge
Functions
Service life
PP
Removes sand, salts, solid matters, and other
substances with a diameter above 5 µ
3–6 months
Granulated car-
bon filter
Absorbs strong-smelling and strong-tasting ma-
terial, chlorine, and chlorine compounds
6–12 months
UDF
Absorbs strong-smelling and strong-tasting ma-
terial, chlorine, and chlorine compounds
6–12 months
T33 A
Absorbs odours and adapt the flavour of the pu-
rified water
6–12 months
T33B
Absorbs odours and adapt the flavour of the pu-
rified water
1 year
Installing the shut-off valve and the water supply connection
1. Switch off the cold-water supply.
2. Fix the T-shaped valve by screwing and tightening the shut-off valve into the water supply con-
nection (use sealing tape for the threads).
3. Disconnect the water supply line from the cold-water supply.
4. Attach the T valve unit in line with the water supply tubes and the water supply.
5. Remove the nut from the supply side of the shut-off valve and slide it over the filter inlet hose.
6. Press the hose end on the exposed fitting of the shut-off valve. Make sure that it has a firm seat.
7. Slide the cap nut on the hose and tighten it on the shut-off valve.
8. Slowly switch on the cold-water supply and check it for leaks.
9. Slowly open the T-shaped shut-off valve to feed the filter with water.
https://www.naturewater.eu Item 51107–51109 Page 6
03 2022-1
Connections
Name
Name
1
Cold-water supply
4
Water-supply connector
2
Shut-off valve
5
Cold-water supply
3
Plastic hose
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction
manual require the written permission of WilTec Wildanger Technik GmbH.
/