Xantrex RS232-XPD User manual

Category
Power supply units
Type
User manual
Operating Manual
Internal RS-232 Interface
for XPD Series
Programmable DC
Power Supply
RS232-XPD
Operating Manual for
Internal RS-232 Interface
for XPD 500 Watt Series
Programmable DC
Power Supply
ii Operating Manual for RS-232 for XPD Series Power Supply
Limited
Warranty
What does this warranty cover and how long does it last?
This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”) and
covers defects in workmanship and materials in your RS-232 Interface Card. This
warranty lasts for a Warranty Period of 5 years from the date of purchase at point of
sale to you, the original end user customer.
What will Xantrex do?
Xantrex will, at its option, repair or replace the defective product free of charge,
provided that you notify Xantrex of the product defect within the Warranty Period,
and provided that Xantrex through inspection establishes the existence of such a
defect and that it is covered by this Limited Warranty.
Xantrex will, at its option, use new and/or reconditioned parts in performing
warranty repair and building replacement products. Xantrex reserves the right to use
parts or products of original or improved design in the repair or replacement. If
Xantrex repairs or replaces a product, its warranty continues for the remaining
portion of the original Warranty Period or 90 days from the date of the return
shipment to the customer, whichever is greater. All replaced products and all parts
removed from repaired products become the property of Xantrex.
Xantrex covers both parts and labor necessary to repair the product, and return
shipment to the customer via a Xantrex-selected non-expedited surface freight
within the contiguous United States and Canada. Alaska and Hawaii are excluded.
Contact Xantrex Customer Service for details on freight policy for return shipments
outside of the contiguous United States and Canada.
How do you get service?
If your product requires troubleshooting or warranty service, contact your merchant.
If you are unable to contact your merchant, or the merchant is unable to provide
service, contact Xantrex directly at:
Phone: 604 422 8595
Toll Free North America: 1 800 667 8422
Fax: 604 421 3056
Release 1.2 iii
Direct returns may be performed according to the Xantrex Return Material
Authorization Policy described in your product manual. For some products, Xantrex
maintains a network of regional Authorized Service Centers. Call Xantrex or check
our website to see if your product can be repaired at one of these facilities.
In any warranty claim, dated proof of purchase must accompany the product and the
product must not have been disassembled or modified without prior written
authorization by Xantrex.
Proof of purchase may be in any one of the following forms:
The dated purchase receipt from the original purchase of the product at point of
sale to the end user, or
The dated dealer invoice or purchase receipt showing original equipment
manufacturer (OEM) status, or
The dated invoice or purchase receipt showing the product exchanged under
warranty
What does this warranty not cover?
This Limited Warranty does not cover normal wear and tear of the product or costs
related to the removal, installation, or troubleshooting of the customer’s electrical
systems. This warranty does not apply to and Xantrex will not be responsible for any
defect in or damage to:
a. the product if it has been misused, neglected, improperly installed, physically
damaged or altered, either internally or externally, or damaged from improper
use or use in an unsuitable environment;
b. the product if it has been subjected to fire, water, generalized corrosion,
biological infestations, and high input voltage from lightning strikes;
c. the product if repairs have been done to it other than by Xantrex or its authorized
service centers (hereafter “ASCs”);
d. the product if it is used as a component part of a product expressly warranted by
another manufacturer;
e. the product if its original identification (trade-mark, serial number) markings
have been defaced, altered, or removed.
iv Operating Manual for RS-232 for XPD Series Power Supply
Disclaimer Product
THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED
BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE
PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS,
GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND LIABILITIES, EXPRESS
OR IMPLIED, STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT,
HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES
OF MANUFACTURER’S LIABILITY, OPERATION OF LAW, CONDUCT, STATEMENT
OR OTHERWISE), INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY
OR CONDITION OF QUALITY, MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT REQUIRED UNDER
APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION
TO THE PERIOD STIPULATED UNDER THIS LIMITED WARRANTY.
IN NO EVENT WILL XANTREX BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, COSTS OR EXPENSES
HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT
RESTRICTION ANY ECONOMIC LOSSES OF ANY KIND, ANY LOSS OR DAMAGE TO
PROPERTY, ANY PERSONAL INJURY, ANY DAMAGE OR INJURY ARISING FROM OR
AS A RESULT OF MISUSE OR ABUSE, OR THE INCORRECT INSTALLATION,
INTEGRATION OR OPERATION OF THE PRODUCT.
Exclusions If this product is a consumer product, federal law does not allow an exclusion of
implied warranties. To the extent you are entitled to implied warranties under federal
law, to the extent permitted by applicable law they are limited to the duration of this
Limited Warranty. Some states and provinces do not allow limitations or exclusions
on implied warranties or on the duration of an implied warranty or on the limitation
or exclusion of incidental or consequential damages, so the above limitation(s) or
exclusion(s) may not apply to you. This Limited Warranty gives you specific legal
rights. You may have other rights which may vary from state to state or province to
province.
Release 1.2 v
Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS
SPECIFICALLY AGREED TO BY IT IN WRITING, XANTREX
a. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY
OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR
OTHER DOCUMENTATION PROVIDED BY IT IN CONNECTION WITH THE
PRODUCT; AND
b. ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES,
COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT,
CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF
SUCH INFORMATION.
THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK.
WARNING:
Limitations
on Use
Please refer to your product user manual for limitations on uses of the product.
Specifically, please note that this power supply is not intended for use in connection
with life support systems and Xantrex makes no warranty or representation in
connection with any use of the product for such purposes.
Xantrex Technology, Inc.
8999 Nelson Way
Burnaby, British Columbia
Canada V5A 4B5
Information
About Your
Power
Supply
Please record the following information when you first open your Power Supply
package:
Release Release 1.2 (2002-06)
Copyright
©
2002 Xantrex Technology Inc. All rights reserved.
Printed in Canada
Model Number ______________________________________________
Serial Number ______________________________________________
Purchased From ______________________________________________
Purchase Date ______________________________________________
vi Operating Manual for RS-232 for XPD Series Power Supply
Power
Supply
Safety
Warnings,
Cautions,
and Notes
Warnings, cautions, and notes are defined and formatted in this manual as shown
below.
WARNING—High Energy and High Voltage
Exercise caution when using and calibrating a power supply. High energy levels
can be stored at the output voltage terminals on a power supply in normal
operation. In addition, potentially lethal voltages exist in the power circuit and on
the output and sense connectors of a power supply with a rated output greater
than 40 V. Filter capacitors store potentially dangerous energy for some time after
power is removed.
!
CAUTION
Operate the power supply in an environment free of flammable gases or fumes.
To ensure that the power supply’s safety features are not compromised, use the
power supply as specified in this manual and do not substitute parts or make any
unauthorized modifications. Contact the service technician for service and repair
help. Repairs must be made by experienced service technicians only.
WARNING
Describes a potential hazard which could result in injury or death, or, a procedure
which, if not performed correctly, could result in injury or death.
!
CAUTION
Describes a procedure which, if not performed correctly, could result in damage
to data, equipment, or systems.
Note
Describes additional operating information which may affect the performance of the
equipment.
Release 1.2 vii
About This Manual
This technical manual is for the RS-232 Interface; a microprocessor-controlled
option card for all models of XPD Series DC output power supplies. This manual
provides you with specifications, user options, and configuration instructions for the
interface, along with a command set which allows you to control your power supply
from a computer console. Error messages and calibration procedures are also
included.
This manual is designed for the user who is familiar with basic electrical theory
especially as it applies to the operation of power supplies. This implies a recognition
of Constant Voltage and Constant Current operation modes and the control of input
and output power, as well as the observance of safe techniques while effecting supply
or pin connections and any changes in switch settings. The user should also have
experience with a computer-based communications software package.
Refer to your power supply manual for installation, configuration, and operating
procedures for your power supply.
Main Sections
Section 1 Features and Specifications Describes the interface and lists its
features and specifications.
Section 2 Installation and Configuration Goes through basic setup
procedures. Describes inspection, cleaning, shipping, and storage procedures.
Section 3 Operation Lists the complete command set, status registers, and error
codes.
Section 4 Calibration Provides detailed procedures for voltage and current
mode calibration as well as over voltage protection (OVP) calibration. Includes
calibration for programming and readback accuracy.
Manual Revisions
The current release of this manual is listed below. Updates may be issued as an
addendum.
Release 1.2 (2002/06)
About This Manual
viii Operating Manual for RS-232 for XPD Series Power Supply
Release 1.2 ix
Contents
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Section 1.
Features and
Specifications
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Features and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Programmable Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Readback Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Section 2.
Installation
and
Configuration
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Initial Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Basic Setup Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Baud Rate Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Flow Control Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Software Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Hardware Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Transmit / Receive Pin Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Remote/Local Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Remote / Local Mode Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Remote Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Local Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Remote Enable (REM) Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
RS-232 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Power Supply Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
User Options and Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
OVP Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
TTL Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
User Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Connector J21 User Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
J21 Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Section 3.
Operation
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
RS-232 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Command Format and Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Command Strings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Command Terminators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Command Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Command Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Contents
x
Operating Manual for RS-232 for XPD Series Power Supply
Accumulated Status, Status, and Fault Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Diagnostic LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Section 4.
Calibration
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Voltage Mode Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Voltage Calibration Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Voltage Program Calibration Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Voltage Readback Calibration Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Current Mode Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Current Calibration Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Current Program Calibration Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Current Readback Calibration Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Over Voltage Protection (OVP) Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Release 1.2 11
Section 1. Features and Specifications
Description
The RS-232 Interface is a microprocessor-controlled option card for all models of
the XPD Series of DC output power supply. Installed internally, the RS-232 interface
card gives you remote digital control of simple test systems. It features fast, 16-bit
resolution for programming and readback and uses bit serial protocol for sending
data between the computer and the interface. The RS-232 interface has an extensive
command set and uses most of the user-programmable features employed by all of
our interfaces.
In addition to the RS-232 port and its interface, this remote control application
requires a computer-based communications software package such as PROCOMM,
XTALK, Windows Terminal Program, equivalent communications software, or low
level or high level language programs. The RS-232 interface is an ideal tool for
reliable, remote power supply control of both research and development
applications.
Figure 1.1 Sample Configuration using RS232 Interface
Features and Specifications
Features and Functions
12 Operating Manual for RS-232 for XPD Series Power Supply
Features and Functions
Features 16-bit programming and readback of voltage and current
Programmable soft limits for voltage and current
Programmable over voltage protection with reset
Easy-to-use, self-documenting command set
Standardized commands for complete communication with any of the supplies
in the system
User-programmable isolated fault, polarity, isolation, and auxiliary, user-defined
output signals.
LED status signals: error, address, remote/local operation, and over voltage
protection.
Foldback in CV or CC mode with reset
Software calibration
Programmable
Functions
Output voltage and current
Soft limits for voltage and current
Over voltage protection
Output enable/disable
Maskable fault interrupt
Hold and trigger
Output relay signals
Readback
Functions
Actual voltage and current
Voltage and current settings
Soft voltage and current limits
Over voltage protection setting
Present and accumulated power supply status
Programming error codes
Fault codes
Power supply model and software version identification
Features and Specifications
Specifications
Release 1.2 13
Specifications
The specifications in this section are warranted at 25°C ±5°C unless otherwise
specified. All specifications are subject to change without notice.
Table 1.1 Specifications for XPD 500 W Series Supply with RS-232 Interface Installed.
Models 7.5-67 18-30 33-16 60-9 120-4.5
Program Resolution
Voltage
Current
OVP
1.2mV
5.2mA
1.2mV
4.6mV
3.6mA
4.6mV
5.1mV
2.9mA
5.1mV
9.3mV
1.3mA
9.3mV
18.6mV
0.7mA
18.6mV
Program Accuracy
1
Voltage
Current
OVP
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model XPD 18-30 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.
10mV
±0.12%
250mA
±0.1%
80mV
75mV
±0.12%
140mA
±0.1%
200mV
75mV
±0.12%
115mA
±0.15%
330mV
150mV
±0.3%
80mA
±0.15%
600mV
180mV
±0.25%
80mA
±0.1%
1.2V
Readback Resolution
Voltage
Current
1.2mV
5.2mA
4.6mV
3.6mA
5.1mV
2.4mA
9.3mV
1.3mA
18.6mV
0.7mA
Readback Accuracy
1
Voltage
Current
30mV
±0.12%
250mA
±0.1%
75mV
±0.12%
140mA
±0.1%
75mV
±0.2%
115mA
±0.15%
150mV
±0.3%
80mA
±0.15%
180mV
±0.25%
80mA
±0.1%
Features and Specifications
Specifications
14 Operating Manual for RS-232 for XPD Series Power Supply
Release 1.2 15
Section 2. Installation and Configuration
Introduction
To use this product, you must have the following equipment:
a compatible model of DC output power supply
serial extender cable (straight through)
computer with an RS-232 interface (serial port)
computer-based communications software package
The RS-232 interface is usually installed at the factory. Your local distributor or
service center can also install the interface, especially for use in a
previously-purchased supply already on site. You must then configure the RS-232
Interface-enhanced supply for your system using the “Basic Setup Procedure” on
page 19. Refer also to Figure 2.1, on page 16, Figure 2.2, on page 17 and Figure 2.3,
on page 18 for drawings of the front panel, the interface subplate, and the RS-232
interface printed circuit board (PCB).
Initial Inspection
On first receiving your unit, perform a quick physical check.
Ensure each package contains a power supply with its RS-232 interface board
installed, and manuals for the power supply and the RS-232 interface. Any
additional parts shipped with the power supply will be identified in the supply's
documentation.
Inspect the unit for any signs of physical damage such as scratches, cracks, or
broken switches, connectors, or displays.
Check the printed circuit board and components if you suspect internal damage.
If the unit is damaged, save all packing materials and notify the carrier immediately.
For additional information, please see the section titled, “Returning Power Supplies
to the Manufacturer” in the manual shipped with your complete unit.
!
CAUTION
If you remove the unit's cover, use proper static control techniques to avoid damage
to static-sensitive components on the printed circuit board.
Installation and Configuration
Initial Inspection
16 Operating Manual for RS-232 for XPD Series Power Supply
Figure 2.1Power Supply Front Panel with RS-232 Interface Installed
!
CAUTION
Use proper static control techniques to avoid damage to static-sensitive components
on the printed circuit board.
Service Request LED (SRQ)
Only used for GPIB option
Remote LED (REM)
Installation and Configuration
Initial Inspection
Release 1.2 17
Figure 2.2 RS-232 Interface Subplate
(Located on Power Supply Rear Panel)
!
CAUTION
Use proper static control techniques to avoid damage to static-sensitive components
on the printed circuit board
S1 Switch
1 Remote/Local Startup
2 Power On Service Reques
t
(Enable/Disable)
3 Not Used
4-8 Primary Address
Selection (A1-A5)
Switch Position
Reference markings
(0) (1)
Error LED (ERR)
Indicates that a programming
error has occurred. Clear with
error query command.
J21 User Signal
Connector
IEEE 488 Connector
Address LED (ADR)
Indicates that the unit is
being addressed by the
master controller.
Installation and Configuration
Initial Inspection
18 Operating Manual for RS-232 for XPD Series Power Supply
Figure 2.3 RS-232 Interface PCB
JUMPER SELECTION
J2 Local OVP control selection [closed] [default]. See page 28.
[open] Front Panel OVP Control.
J3 User TTL shutdown (S/D)
selection
[1-2] User TTL S/D line active low. See page 31.
[2-3] [default] User TTL S/D line active high.
J20 Remote OVP Control Selection [closed] [default]. See page 28.
[open]
J10 RS-232 (J4) transmit and
receive pin selection
[3-1] Receive on pin 3 [default]
[4-6] Transmit on pin 2 [default]
[3-5] Receive on pin 2
[4-2] Transmit on pin 3
J16 RS-232 flow control selection of
RTS/CTS (ready to send/clear
to send) or DTR/DSR (data
terminal ready/data set ready)
[1-3][4-6] [default] RTS input on pin 7 (used with
CTS output on pin 8)
[3-5][4-6] DTR input on pin 4 (used with DSR
output on pin 6)
J17 RS-232 flow control selection of
RTS/CTS or DTR/DSR
[2-4][[3-5] [default] CTS output on pin 8 (used
with RTS input on pin 7)
[2-4][1-3] DSR output on pin 6 (used with DTR
input on pin 4)
Note: All other jumpers are not user-selectable.
LED INDICATORS
D1 Red Diagnostic LED Bus error or soft restart on Slave circuitry.
D4 Red Diagnostic LED Soft restart on Master circuitry.
D5 Green Diagnostic LED Bus error on Master circuitry.
EPROMS
U18 Slave EPROM See revision number stamped on EPROM.
U1 Master EPROM See revision number stamped on EPROM.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Xantrex RS232-XPD User manual

Category
Power supply units
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI