Programmable DC
Power Supply
Operation Manual
XPD 7.5-67
XPD 18-30
XPD 33-16
XPD 60-9
XPD 120-4.5
About AMETEK
AMETEK Programmable Power, Inc., a Division of AMETEK, Inc., is a global leader in the design
and manufacture of precision, programmable power supplies for R&D, test and measurement,
process control, power bus simulation and power conditioning applications across diverse
industrial segments. From bench top supplies to rack-mounted industrial power subsystems,
AMETEK Programmable Power is the proud manufacturer of Elgar, Sorensen, California
Instruments and Power Ten brand power supplies.
AMETEK, Inc. is a leading global manufacturer of electronic instruments and electromechanical
devices with annualized sales of $2.5 billion. The Company has over 11,000 colleagues working
at more than 80 manufacturing facilities and more than 80 sales and service centers in the United
States and around the world.
Trademarks
AMETEK is a registered trademark of AMETEK, Inc. Sorensen is a trademark owned by AMETEK,
Inc. Other trademarks, registered trademarks, and product names are the property of their
respective owners and are used herein for identification purposes only.
Notice of Copyright
XPD Series Programmable DC Power Supply Operation Manual
© 2007 AMETEK Programmable
Power, Inc. All rights reserved.
Exclusion for Documentation
UNLESS SPECIFICALLY AGREED TO IN WRITING, AMETEK PROGRAMMABLE POWER, INC.
(“AMETEK”):
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY
TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER
DOCUMENTATION.
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR
EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL,
WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH
INFORMATION WILL BE ENTIRELY AT THE USER’S RISK, AND
(c) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH,
ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE
TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED AMETEK CONTENT
IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION, WHICH IS POSTED AT
WWW.PROGRAMMABLEPOWER.COM.
Date and Revision
April 2009 Revision D
Part Number
TM-PDOP-01XN
Contact Information
Telephone: 800 733 5427 (toll free in North America)
858 450 0085 (direct)
Fax: 858 458 0267
Email: sales@programmablepower.com
Web: www.programmablepower.com
i
This page intentionally left blank.
ii
Important Safety Instructions
Before applying power to the system, verify that your product is configured properly for your
particular application.
WARNIN
G
Hazardous voltages may be present when covers are removed. Qualified
personnel must use extreme caution when servicing this equipment.
Circuit boards, test points, and output voltages also may be floating above
(below) chassis ground.
WARNIN
G
The equipment used contains ESD sensitive parts. When installing
equipment, follow ESD Safety Procedures. Electrostatic discharges might
cause damage to the equipment.
Only qualified personnel who deal with attendant hazards in power supplies, are allowed to perform
installation and servicing.
Ensure that the AC power line ground is connected properly to the Power Rack input connector or
chassis. Similarly, other power ground lines including those to application and maintenance
equipment must be grounded properly for both personnel and equipment safety.
Always ensure that facility AC input power is de-energized prior to connecting or disconnecting any
cable.
In normal operation, the operator does not have access to hazardous voltages within the chassis.
However, depending on the user’s application configuration, HIGH VOLTAGES HAZARDOUS TO
HUMAN SAFETY may be normally generated on the output terminals. The customer/user must
ensure that the output power lines are labeled properly as to the safety hazards and that any
inadvertent contact with hazardous voltages is eliminated.
Guard against risks of electrical shock during open cover checks by not touching any portion of the
electrical circuits. Even when power is off, capacitors may retain an electrical charge. Use safety
glasses during open cover checks to avoid personal injury by any sudden component failure.
Neither AMETEK Programmable Power Inc., San Diego, California, USA, nor any of the subsidiary
sales organizations can accept any responsibility for personnel, material or inconsequential injury,
loss or damage that results from improper use of the equipment and accessories.
SAFETY SYMBOLS
iii
This page intentionally left blank.
iv
Product Family: XPD Series Programmable DC Power Supply
Warranty Period: Five Years
WARRANTY TERMS
AMETEK Programmable Power, Inc. (“AMETEK”), provides this written warranty covering the
Product stated above, and if the Buyer discovers and notifies AMETEK in writing of any defect in
material or workmanship within the applicable warranty period stated above, then AMETEK may,
at its option: repair or replace the Product; or issue a credit note for the defective Product; or
provide the Buyer with replacement parts for the Product.
The Buyer will, at its expense, return the defective Product or parts thereof to AMETEK in
accordance with the return procedure specified below. AMETEK will, at its expense, deliver the
repaired or replaced Product or parts to the Buyer. Any warranty of AMETEK will not apply if the
Buyer is in default under the Purchase Order Agreement or where the Product or any part
thereof:
is damaged by misuse, accident, negligence or failure to maintain the same as
specified or required by AMETEK;
is damaged by modifications, alterations or attachments thereto which are not
authorized by AMETEK;
is installed or operated contrary to the instructions of AMETEK;
is opened, modified or disassembled in any way without AMETEK’s consent; or
is used in combination with items, articles or materials not authorized by AMETEK.
The Buyer may not assert any claim that the Products are not in conformity with any warranty
until the Buyer has made all payments to AMETEK provided for in the Purchase Order Agreement.
PRODUCT RETURN PROCEDURE
1. Request a Return Material Authorization (RMA) number from the repair facility (must be
done in the country in which it was purchased):
In the USA, contact the AMETEK Repair Department prior to the return of the
product to AMETEK for repair:
Telephone: 800-733-5427, ext. 2295 or ext. 2463 (toll free North America)
858-450-0085, ext. 2295 or ext. 2463 (direct)
Outside the United States, contact the nearest Authorized Service Center
(ASC). A full listing can be found either through your local distributor or our
website, www.programmablepower.com, by clicking Support and going to the
Service Centers tab.
2. When requesting an RMA, have the following information ready:
Model number
Serial number
Description of the problem
NOTE: Unauthorized returns will not be accepted and will be returned at the shipper’s expense.
NOTE: A returned product found upon inspection by AMETEK, to be in specification is subject to
an evaluation fee and applicable freight charges.
v
This page intentionally left blank.
vi
vii
About This Manual
This Operating Manual contains operating information for the XPD Series of
high-performance, switching, laboratory power supplies, available in several voltage
models at 500 watts. It provides information on features and specifications,
installation procedures, and basic functions testing, as well as operating procedures
for using both front panel control and remote analog programming functions.
Who Should Use This Manual
This manual is designed for the user who is familiar with basic electrical theory,
especially as they apply to the operation of power supplies. This implies a
recognition of Constant Voltage and Constant Current operating modes and the
control of input and output power, as well as the observance of safe techniques while
making supply or pin connections and any changes in switch settings.
Main Sections
Section 1 Features and Specifications Describes the power supply and lists
its features and specifications.
Section 2 Installation Goes through basic setup procedures. Describes
inspection, cleaning, shipping, and storage procedures. Includes AC input
connection, basic functions testing, and load and sense lines connections.
Section 3 Local Operation Provides procedures for local (front panel)
operation. Includes procedures for using over voltage protection, shutdown function,
multiple supplies, and over temperature protection.
Section 4 Remote Operation Covers remote analog programming operation
and remote monitoring of output voltage and current.
About This Manual
viii Operating Manual for XPD Series Power Supply
-
ix
Contents
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Section 1.
Features and
Specifications
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Features and Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Front Panel Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Rear Panel Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Output Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Rear Panel J210 Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Making J210 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Additional Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Input Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Additional Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Remote Programming and Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Section 2.
Installation Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Basic Setup Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Inspection, Cleaning, and Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Initial Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Periodic Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Returning Power Supplies to the Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Return Material Authorization Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Packaging for Shipping or Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Location, Mounting, and Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Rack Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
AC Input Power Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
AC Input Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
AC Input Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Functional Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Power-on Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Voltage Mode Operation Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Current Mode Operation Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Load Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Load Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Making Load Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Inductive Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Connecting Multiple Loads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Remote Sensing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Sense Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
x Operating Manual for XPD Series Power Supply
Section 3.
Local
Operation
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Standard Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Operating Modes and Automatic Crossover . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Constant Voltage Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Constant Current Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Setting the Current Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Setting the Supply to Operate in CI Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Automatic Mode Crossover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Shipped Configuration (Local Control Mode). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Using Over Voltage Protection (OVP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Defining the OVP Setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
OVP Circuit Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Using the Shutdown Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Controlling Shutdown Function via J210 Connector . . . . . . . . . . . . . . . . . . . . . 39
Master-Slave Tracking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Using Multiple Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
User Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Emergency Shutdown. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Unusual or Erratic Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Trouble Shooting for Operators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Section 4.
Remote
Operation
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Remote Digital Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Remote Analog Programming of Output Voltage and Current Limit . . . . . . . . . . . . . 49
Remote Programming Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Programming Output Voltage with a 0-10 Vdc Voltage Source . . . . . . . . . . . . 50
Programming Output Current with a 0-10 Vdc Voltage Source. . . . . . . . . . . . . 50
Readback and Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Voltage and Current Readback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Status Flags. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
11
Section 1. Features and Specifications
Description
The XPD Series of DC power supplies provides stable, variable output voltage and
current for a broad range of development and system requirements. The units use
high-frequency soft-switching technology to achieve high power density and retain
a small package size. They feature a built-in analog programming interface, with
optional RS-232 and IEEE-488 controlled programming, making this series the first
choice in flexible power system design. See Table 1.1 for the list of available models.
Table 1.1 500 Watt Series Models
Features and Options
The power supply delivers simultaneous digital displays for both voltage and
current, and bar graph displays for monitoring transient changes, which gives the
user the benefit of continuous, up-to-date information.
Active Power Factor Correction (PFC) delivers lower input current and input
current harmonics.
Ten-turn voltage and current controls permits high resolution setting of the
output.
The automatic crossover system allows the power supply to automatically
switch operating modes between current or voltage mode.
Multiple units can be connected in parallel or series to produce greater diversity
or for use in high precision applications.
Short-circuit-proof power outlets give greater operating safety.
A built-in Analog Programming (APG) Interface provides analog signal control
of voltage and current, overvoltage protection (OVP), master/slave output
tracking, and remote ENABLE/DISABLE for safety and precision.
Model Output Voltage Output Current
7.5-67 0-7.5 V 0-67 A
18-30 0-18 V 0-30 A
33-16 0-33 V 0-16 A
60-9 0-60 V 0-9 A
120-4.5 0-120 V 0-4.5 A
Section 1. Features and Specifications
Front Panel Controls
12 Operating Manual for XPD Series Power Supply
This unit may be equipped with an optional internal GPIB or RS-232 control for
remote digital programming and readback.
Remote output sensing provides load cable compensation up to 5 V/line
(3 V/line for 7.5 V model).
A rack mount kit (Option RM) is also available for this product.
Front Panel Controls
See Figure 1.1 to review the displays, LEDs, indicators, and controls located on the
power supply’s front panel. Check the following sections for additional descriptions
for front panel controls and functions.
“Mechanical Specifications” on page 21
“Functional Tests” on page 29
“Standard Operation” on page 35l
Figure 1.1 500 Watt Series Power Supply Front Panel
SQR: Service Request.
On M9B equipped units only
REM: Supply is under
Remote Control
S/D: Unit is in Stand By.
Supply output is disabled.
OVP ADJ: Single turn Over
Voltage Protection threshold
adjusting potentiometer
Voltage Mode Operation
Indicator (green LED)
10-turn Voltage Control Knob
AC Power Switch
Safety Ground Binding Post (green or
gray)
Digital Display of DC
Output (volts, amperes)
Analog Bar Graph Display
Current Mode Operation
Indicator (red LED)
10-turn Current Control Knob
Return (-) Output BInding Post (black)
Return (+) Output BInding Post
(red)
Section 1. Features and Specifications
Rear Panel Connectors
13
Rear Panel Connectors
Figure 1.2 500 Watt Power Supply Rear Panel (7.5 V and 18 V)
Figure 1.3 500 Watt Power Supply Rear Panel (33 V to 120 V)
Remote Sensing
Port: Remove
Default Jumpers to
use Remote Sensing Blank Sub-Plate:
Replaced if Digital
Programming
Option is Installed
Fan Exhaust
Vents:
Do not obstruct
Analog
Programming and
Readback
Output Busbars
IEC 320 AC Input
Connector
Busbar Cover
Remote Sensing
Port: Remove
Default Jumpers to
use Remote Sensing
DC Output
Connector:
33 V, 60 V and
120 V models
IEC 320 AC Input
Connector
Section 1. Features and Specifications
Rear Panel Connectors
14 Operating Manual for XPD Series Power Supply
Output
Connectors
Low Voltage Models Equipped with positive and negative busbars. The busbars
are offset to facilitate load cable connections.
.
Figure 1.4 Output Busbars - note polarity markings
(Low Voltage Models)
High Voltage Models High voltage models are equipped with a 4-terminal output
block. The top two are positive terminals whereas the lower two are negative. Screw
clamps are used to secure load connections.
Figure 1.5 Output Terminal - note polarity markings
(High Voltage Models)
WARNING
Disconnect the AC input before making any connections to the unit.
WARNING
Disconnect the AC input before making any connections. Lethal voltages may be
present at the output terminals for up to 15 seconds after the AC power has been
removed.
Section 1. Features and Specifications
Rear Panel Connectors
15
Rear Panel
J210
Connector
The J210 Analog Interface connector is a 15-pin female DSUB connector located on
the rear panel. See Figure 1.6. Use the J210 programming, monitoring, and
shutdown 15 pin DSUB connector for remote programming and monitoring
functions. See Figure 1.2 for the location of the J210 connector at the rear panel. We
recommend that you mate the J210 connector with a 15-pin male connector, such as
a Tyco 747908-2 or equivalent.
The J210 connector provides access to the following functions:
Remote programming of both output voltage and current
Calibrated readback signals for remote monitoring of output voltage and output
current
Isolated remote shutdown function using a 5-15 V signal
See Figure 1.6 for a graphic presentation of the J210 connector and its pinouts.
Figure 1.6 Analog Interface Programming and Monitoring J210 Connector
See Table 1.2 for a list of the J210 connector pin numbers, their references, and
corresponding functions.
9
1
8
15
Section 1. Features and Specifications
Rear Panel Connectors
16 Operating Manual for XPD Series Power Supply
Table 1.2 Rear Panel J210 Connector Pins and Functions
Pin Reference Name Function
J210-1 TTL S/D
RTN
Shutdown Signal Return
()
Return for shutdown signal1.
J210-2 TTL S/D Shutdown Input (+) Input for shutdown signal.1
J210-3 N/C No connection None.
J210-4 N/C No connection None.
J210-5 IPGM Output Current Limit
Programming Input
Input for current limit programming
signals from an analog device.
J210-6 VRMT
SELECT
Remote Output Voltage
Programming Select
Selects remote output voltage
programming when to jumpered to
pin 8.2
J210-7 IRMT
SELECT
Remote Output Current
Limit Programming
Select
Selects remote output current limit
programming when jumpered to
pin 8.2
J210-8 AGND Auxiliary Ground Auxiliary ground.
J210-9 N/C No connection None.
J210-10 N/C No connection None.
J210-11 N/C No connection None.
J210-12 IMON Output current monitor Output for output current monitor
signal.
J210-13 PGM/MON
RTN
Program/Monitor Return Return for voltage and current
program and monitor signals.
J210-14 VPGM Output Voltage
Programming Input
Input for voltage programming
signals from an analog device.
J210-15 VMON Output Voltage Monitor Output for output voltage monitor
signal.
1. The TTL shutdown circuit is isolated to 500 V from the power supply output and chassis.
2. Jumpering pins J210-6, J210-7, and J210-8 will select both remote output voltage
programming and remote output current limit programming.
Section 1. Features and Specifications
Rear Panel Connectors
17
Making J210
Connections
Wiring
For most connectors and jumpers, use any suitable wire such as 16 to 24 AWG
stranded wire. For lowest noise performance, use shielded pair wiring of 16 to 24
AWG. Use the shortest leads possible. Ground the shield to pin 8 (auxiliary ground)
on the J210 connector or to the chassis via one of the J210 connector screws.
!
CAUTION
Program/monitor signal and return are internally connected to the power
supply negative output. Do not attempt to bias these away from that
potential.
!
CAUTION
To maintain the isolation of the power supply output and prevent ground
loops, use an isolated (ungrounded) programming source when operating
the power supply via remote analog control at the J210 connector.
!
CAUTION
Before making connections from external circuits to the J210 connector, turn
the power supply OFF and wait until the front panel displays have gone out.
WARNING
There is a potential shock hazard at the output when using a power supply
with a rated output greater than 40 V. Use load wiring with a minimum
insulation rating equivalent to the maximum output voltage of the power
supply. For example, select TEW, 105 °C, 300 V wiring for use with a
120 V, 4.5 A power supply.
Section 1. Features and Specifications
Electrical Specifications
18 Operating Manual for XPD Series Power Supply
Electrical Specifications
These specifications are warranted over a temperature range of 0 °C to 50 °C
with local sense. Above 50 °C, derate output linearly to zero at 70 °C. Nominal
line voltages are 100/120/200/230/240 Vac. Specifications and characteristics
refer to a single output model unless otherwise stated, and specifications apply
to either front or rear outputs unless noted.
Table 1.3 Electrical Specifications for 7.5 V to 120 V Models
Models 7.5-67 18-30 33-16 60-9 120-4.5
Output Ratings:
Output Voltage
Output Current
Output Power
0-7.5 V
0-67 A 1
502.5 W
0-18 V
0-30 A
540 W
0-33 V
0-16 A
528 W
0-60 V
0-9 A
540 W
0-120 V
0-4.5 A
540 W
Line regulation: 2
Voltage (0.01% of Vmax + 2 mV)
Current (0.01% of Imax + 1 mA)
2.8 mV
7.7 mV
3.8 mV
4mV
5.3 mV
2.6 mV
8mV
1.9 mV
14 mV
1.5 mV
Load Regulation:3
Voltage (0.01% of Vmax + 2 mV)
Current (0.01% of Imax + 5 mA)
2.8 mV
11.7 mA
3.8 mV
8mA
5.3 mV
6.6 mA
8mV
5.9 mA
14 mV
5.5 mA
Meter Accuracy
Voltage (1% of Vmax + 1 count)
Current (1% of Imax + 1 count)
0.2 V
0.8 A
0.3 V
0.4 A
0.5 V
0.3 A
0.7 V
0.2 A
2.2 V
0.2 A
Output Noise (0-20 MHz):
Voltage (p-p) 50 mV 50 mV 75 mV 125 mV 180 mV
Output Ripple (0-100 kHz) (rms):
Voltage
Current45mV
250 mA
5mV
250 mA
7.5 mV
150 mA
10 mV
150 mA
20 mV
75 mA
Drift (60 minutes):5
Voltage (0.15% of Vmax)
Current (0.3% of Imax)
11.3 mV
201 mA
27 mV
90 mA
49.5 mV
48 mA
90 mV
27 mA
180 mV
13.5 mA
Drift (8 hours): 6
Voltage (0.03% of Vmax)
Current (0.05% of Imax)
2.3 mV
34 mA
5.4 mV
15 mA
9.9 mV
8mA
18 mV
4.5 mA
36 mV
2.3 mA
Temperature Coefficient: 7
Voltage (0.015% of Vmax/º C
Current (0.02% of Imax/º C
1.2 mV
13.4 mA
2.7 mV
6mA
5mV
3.2 mA
9mV
1.8 mA
18 mV
0.9 mA
OVP Adjustment Range:
Minimum (5% of Vmax)
Maximum (110% of Vmax)
0.4 V
8.3 V
0.9 V
19.8 V
1.7 V
36.3 V
3V
66 V
6V
132 V
Efficiency 881% 83% 85% 85% 84%
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50