ML Accessories SHE2GEMP User manual

Type
User manual
INSTALLATION & MAINTENANCE MANUAL
SHE1BEMP / SHE1GEMP
SHE2BEMP / SHE2GEMP
These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
SHE1BEMP / SHE1GEMP / SHE2BEMP / SHE2GEMP
GENERAL INSTRUCTIONS
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse, or circuit breaker
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
This product is Class I and must be earthed
This product is IP65 rated
SAFETY
INSTALLATION
Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP
rated junction boxes should be used where required
Remove the diffuser by unscrewing the four hex screws at the front of the diffuser
Using the baseplate as a template, mark the location for, and drill the fixing holes ensuring not to infringe with
any gas/water pipes or electrical cables
Feed the mains cable through the rubber grommet to retain IP rating, and secure the baseplate to the surface
Ensuring correct polarity is observed, carefully wire as shown in Fig. 1
Fig. 1
Fig. 2
Ensure the earth lead on the LED plate is secured correctly to the earth lead on the body of the fitting
Fix the LED tray to the body
Choose the required colour temperature by means of the three-position switch (see Fig. 2)
• Please see DIP switch layout to set up the
sensor
• Replace the diffuser ensuring seal is in place
• Switch on and check for correct operation
ensuring the green indicator LED is
illuminated
We recommend, on commissioning the
installation, a minimum charge period of
24 hours before carrying out an emergency
duration test
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
SHE1BEMP / SHE1GEMP / SHE2BEMP / SHE2GEMP
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of
the circuit cable, fuse, or circuit breaker
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
This product is Class I and must be earthed
This product is IP65 rated
INSTALLATION
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
Remove the diffuser by unscrewing the four hex screws at the front of the diffuser
Using the baseplate as a template, mark the location for, and drill the fixing holes ensuring not to
infringe with any gas/water pipes or electrical cables
Feed the mains cable through the rubber grommet to retain IP rating, and secure the baseplate to the
surface
Ensuring correct polarity is observed, carefully wire as shown in Fig. 1
Fig. 1
Ensure the earth lead on the LED plate is secured correctly to the earth lead on the body of the fitting
Fix the LED tray to the body
Choose the required colour temperature by means of the three-position switch (see Fig. 2)
Fig. 2
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
SHE1BS / SHE1GS / SHE2BS / SHE2GS
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of
the circuit cable, fuse, or circuit breaker
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
This product is Class I and must be earthed
This product is IP65 rated
INSTALLATION
Note - Microwave sensors may not be suitable for all installations, for example enclosed spaces, as they are
able to detect movement through non-metallic surfaces like plasterboard and thin doors.
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
Remove the diffuser by unscrewing the four hex screws at the front of the diffuser
Using the baseplate as a template, mark the location for, and drill the fixing holes ensuring not to
infringe with any gas/water pipes or electrical cables
Feed the mains cable through the rubber grommet to retain IP rating, and secure the baseplate to the
surface
Ensuring correct polarity is observed, carefully wire as shown in Fig. 1
Fig. 1
Ensure the earth lead on the LED plate is secured correctly to the earth lead on the body of the fitting
Fix the LED tray to the body
Choose the required colour temperature by means of the three-position switch (see Fig. 2)
Fig. 2
SENSOR DIP SWITCH LAYOUT
DIP SWITCH SETTINGS
When the ambient light level is below the “Open” lux level, the sensor switches on the luminaire. When
the ambient light level is above the “Close” lux level, the sensor switches off the luminaire
Note: The sensor fitted in this luminaire can differentiate between natural daylight and artificial light and will only
be activated by natural daylight.
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
This product is not suitable for installation in or near a coastal or marine environment.
GENERAL
This product contains a light source of energy efficiency class C to Regulation (EU) No. 2019/2015.
This product contains a non-replaceable LED light source and a control gear which can be replaced by a
professional.
1 2 3 4 Open Close
I ON ON ON ON 5 Lux 25 Lux
II ON ON ON - 10 Lux 50 Lux
III ON ON - ON 25 Lux 75 Lux
IV ON ON - - 50 Lux 100 Lux
V ON - ON - 100 Lux 200 Lux
VI ON - - - 150 Lux 300 Lux
VII - ON - - 200 Lux 400 Lux
VIII - - - - Disable
SENSOR DIP SWITCH LAYOUT
DIP SWITCH SETTINGS
When the ambient light level is below the “Open” lux level, the sensor switches on the luminaire. When
the ambient light level is above the “Close” lux level, the sensor switches off the luminaire
Note: The sensor fitted in this luminaire can differentiate between natural daylight and artificial light and will only
be activated by natural daylight.
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
This product is not suitable for installation in or near a coastal or marine environment.
GENERAL
This product contains a light source of energy efficiency class C to Regulation (EU) No. 2019/2015.
This product contains a non-replaceable LED light source and a control gear which can be replaced by a
professional.
1 2 3 4 Open Close
I ON ON ON ON 5 Lux 25 Lux
II ON ON ON - 10 Lux 50 Lux
III ON ON - ON 25 Lux 75 Lux
IV ON ON - - 50 Lux 100 Lux
V ON - ON - 100 Lux 200 Lux
VI ON - - - 150 Lux 300 Lux
VII - ON - - 200 Lux 400 Lux
VIII - - - - Disable
SENSOR DIP SWITCH LAYOUT
DIP SWITCH SETTINGS
When the ambient light level is below the “Open” lux level, the sensor switches on the luminaire. When the
ambient light level is above the “Close” lux level, the sensor switches off the luminaire
Note: The sensor fitted in this luminaire can differentiate between natural daylight and artificial light and will
only be activated by natural daylight.
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
This product is not suitable for installation in or near a coastal or marine environment.
GENERAL
This product contains a light source of energy efficiency class D to Regulation (EU) No. 2019/2015.
This product contains a non-replaceable LED light source and a control gear which can be replaced by a
professional.
Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not
use aggressive cleaning products or solvents which may damage the product.
This product is non-dimmable.
This product should be dismantled for disposal when it reaches the end of its life. Please see website for
dismantling instructions.
This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities
for where facilities exist.
The batteries in this luminaire are Lithium Ion and must be disposed of correctly. Please contact the local
authorities for the disposal of this toxic waste.
WARRANTY
TESTING FOR EMERGENCY LUMINAIRES
This product has a warranty of 5 years (excluding battery) from date of purchase. Failure to install this product
in accordance with the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal
of the batch code will invalidate the warranty. If this product should fail within its warranty period, it should
be returned to the place of purchase for a free of charge replacement. ML Accessories does not accept
responsibility for any installation costs associated with the replacement product. Your statutory rights are not
affected. ML Accessories reserve the right to alter product specification without prior notice.
Recommended routine test procedure in accordance with BS5266
Daily check – check LED charge indicator is illuminated
Monthly functional test - simulate a mains supply failure for approx. 30 seconds by operation of key switch
or switching off circuit breaker. Ensure normal supply is restored after test and ensure charge indicator is
illuminated
Annual 3-hour duration test - simulate a mains supply failure for 3-hour continuous test by operation
of key switch or switching off circuit breaker. Ensure normal supply is restored after test and ensure charge
indicator is illuminated
If the luminaire fails any of the above tests, please contact a qualified electrician. See below for test
record sheet
AVOCT21_V2
ML Accessories Limited LU5 4LT
www.mlaccessories.co.uk
134
INTERNATIONAL
CONTACT DETAILS
INTERNATIONAL
CONTACT DETAILS
INTERNATIONAL
CONTACT DETAILS
-20°C~
50°C
TA