Compaq GS80 User manual

Type
User manual
Compaq Computer Corporation
AlphaServer GS80/160/320
User’s Guide
Order Number: EK-GS320-UG. C01
This guide is intended for those who manage, operate, or service the
AlphaServer GS160/320 system and the AlphaServer GS80 rack
system. It covers configuration guidelines, operation, system
management, and basic troubleshooting.
Revised September 2000
© 2000 Compaq Computer Corporation.
COMPAQ, the Compaq logo, and AlphaServer registered in U.S. Patent and Trademark Office. OpenVMS,
StorageWorks, and Tru64 are trademarks of Compaq Information Technologies Group, L.P.
Portions of the software are © copyright Cimetrics Technology. Linux is a registered trademark of Linus
Torvalds in several countries. UNIX is a registered trademark of The Open Group in the U.S. and other
countries. All other product names mentioned herein may be trademarks of their respective companies.
Compaq shall not be liable for technical or editorial errors or omissions contained herein. The information in
this document is subject to change without notice.
FCC Notice
This equipment generates, uses, and may emit radio frequency energy. The equipment has been type tested
and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC rules, which are
designed to provide reasonable protection against such radio frequency interference.
Operation of this equipment in a residential area may cause interference in which case the user at his own
expense will be required to take whatever measures may be required to correct the interference.
Any modifications to this device—unless expressly approved by the manufacturer—can void the user’s
authority to operate this equipment under part 15 of the FCC rules.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not
expressly approved by Compaq Computer Corporation may void the user's authority to operate the
equipment.
Cables
Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in
order to maintain compliance with FCC Rules and Regulations.
Taiwanese Notice
Japanese Notice
Canadian Notice
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Avis Canadien
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur
du Canada.
European Union Notice
Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage
Directive (73/23/EEC) issued by the Commission of the European Community.
Compliance with these directives implies conformity to the following European Norms (in brackets are the
equivalent international standards):
EN55022 (CISPR 22) - Electromagnetic Interference
EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity
EN60950 (IEC950) - Product Safety
Achtung!
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen
verantwortlich ist.
Attention!
Ceci est un produit de Classe A. Dans un environnement domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l'utilisateur de prendre les mesures spécifiques
appropriées.
v
Contents
Preface ........................................................................................................................xi
Chapter 1 Introduction
1.1 AlphaServer GS160/320 and GS80 Systems......................................... 1-2
1.2 Firmware and Utilities Overview ......................................................... 1-4
1.3 System Architecture.............................................................................. 1-5
Chapter 2 GS160/320 System Overview
2.1 System Characteristics ......................................................................... 2-2
2.2 System Box Architecture....................................................................... 2-4
2.3 Quad Building Block (QBB) Components ............................................. 2-6
2.3.1 Backplane.............................................................................................. 2-8
2.3.2 CPU Module........................................................................................ 2-10
2.3.3 Memory Module .................................................................................. 2-11
2.3.4 Directory Module................................................................................. 2-12
2.3.5 Power Modules .................................................................................... 2-13
2.3.6 Power System Manager Module.......................................................... 2-14
2.3.7 Clock Splitter Module ......................................................................... 2-15
2.3.8 I/O Riser Module ................................................................................. 2-16
2.3.9 Global Port Module ............................................................................. 2-17
2.3.10 Distribution Board........................................................................ 2-18
2.3.11 Hierarchical Switch ...................................................................... 2-20
2.4 Power System...................................................................................... 2-22
2.4.1 AC Input Box....................................................................................... 2-24
2.5 PCI I/O ................................................................................................ 2-26
2.6 Control Panel ...................................................................................... 2-28
2.6.1 Control Panel LEDs ............................................................................ 2-30
vi
Chapter 3 GS160/320 System Configuration Rules
3.1 GS160 System Cabinet.......................................................................... 3-2
3.2 GS320 System Cabinets........................................................................ 3-4
3.3 Power Cabinet....................................................................................... 3-6
3.3.1 Power Supply Slot Assignments ........................................................... 3-8
3.4 System Box.......................................................................................... 3-10
3.5 QBB Color Code .................................................................................. 3-12
3.6 Memory Configurations ...................................................................... 3-14
3.7 Memory Interleaving Guidelines ........................................................ 3-16
3.8 PCI Boxes............................................................................................ 3-18
3.9 PCI Box Slot Configuration................................................................. 3-20
3.10 Expander Cabinet ............................................................................... 3-22
Chapter 4 GS80 Rack System Overview
4.1 Rack System Characteristics ................................................................ 4-2
4.2 System Drawer Architecture................................................................. 4-4
4.3 System Drawer Modules ....................................................................... 4-6
Chapter 5 GS80 Rack System Configuration Rules
5.1 Rack....................................................................................................... 5-2
5.2 Rack Power System............................................................................... 5-4
Chapter 6 Booting and Installing an Operating System
6.1 Powering Up the System....................................................................... 6-2
6.1.1 SCM Power-Up Display ........................................................................ 6-4
6.1.2 SRM Power-Up Display ........................................................................ 6-6
6.2 Setting Boot Options ........................................................................... 6-10
6.2.1 Bootdef_dev......................................................................................... 6-10
6.2.2 Boot_file .............................................................................................. 6-11
6.2.3 Boot_osflags......................................................................................... 6-12
6.2.4 ei*0_inet_init or ew*0_inet_init.......................................................... 6-14
6.2.5 ei*0_protocols or ew*0_protocols......................................................... 6-15
6.3 Booting Tru64 UNIX........................................................................... 6-16
6.3.1 Booting Tru64 UNIX Over the Network ............................................. 6-18
6.4 Installing Tru64 UNIX........................................................................ 6-20
6.5 Booting OpenVMS............................................................................... 6-22
6.5.1 Booting OpenVMS from the InfoServer.............................................. 6-24
6.6 Installing OpenVMS ........................................................................... 6-26
vii
Chapter 7 Operation
7.1 SRM Console ......................................................................................... 7-2
7.1.1 SRM Command Overview ..................................................................... 7-4
7.1.2 Setting the Control Panel Message....................................................... 7-6
7.2 Displaying the System Configuration................................................... 7-7
7.2.1 Show Boot Command ............................................................................ 7-7
7.2.2 Show Config Command......................................................................... 7-8
7.2.3 Show Device Command....................................................................... 7-16
7.2.4 Show Memory Command .................................................................... 7-18
7.3 Setting SRM Environment Variables ................................................. 7-19
7.4 Setting SRM Console Security ............................................................ 7-20
7.4.1 Setting Tru64 UNIX or OpenVMS Systems to Auto Start ................. 7-21
7.5 Changing the Default Boot Device...................................................... 7-21
7.6 Soft Partitioning.................................................................................. 7-22
7.7 Hard Partitioning................................................................................ 7-26
Chapter 8 Using the System Control Manager
8.1 Console Serial Bus Subsystem.............................................................. 8-2
8.2 System Control Manager Overview ...................................................... 8-4
8.3 SCM COM1 Operating Modes............................................................... 8-6
8.3.1 Bypass Modes........................................................................................ 8-8
8.4 Console Device Setup .......................................................................... 8-10
8.5 Entering the SCM ............................................................................... 8-12
8.6 SRM Environment Variables for COM1 ............................................. 8-13
8.7 SCM Command-Line Interface ........................................................... 8-14
8.7.1 Defining the COM1 Data Flow ........................................................... 8-17
8.7.2 Displaying the System Status............................................................. 8-18
8.7.3 Displaying the System Environment.................................................. 8-20
8.7.4 Power On and Off, Reset, and Halt..................................................... 8-22
8.7.5 Configuring Remote Dial-In................................................................ 8-24
8.7.6 Configuring Alert Dial-Out................................................................. 8-26
8.7.7 Resetting the Escape Sequence........................................................... 8-29
8.8 Troubleshooting Tips........................................................................... 8-30
Appendix A Jumpering Information
A.1 PCI Backplane Jumpers........................................................................A-1
A.2 HPM Jumpers .......................................................................................A-2
A.3 Standard I/O Module Jumpers..............................................................A-2
viii
Glossary
Index
Examples
6–1 SCM Power-Up Display ........................................................................ 6-2
6–2 SRM Power-Up Display ........................................................................ 6-6
6–3 Booting Tru64 UNIX from a Local SCSI Disk .................................... 6-16
6–4 RIS Boot .............................................................................................. 6-18
6–5 Tru64 UNIX Installation Display ....................................................... 6-20
6–6 Booting OpenVMS from a Local Disk ................................................. 6-22
6–7 InfoServer Boot ................................................................................... 6-24
6–8 OpenVMS Installation Menu .............................................................. 6-26
7–1 Set Ocp_Text Command...................................................................... 7-6
7–2 Show Boot*............................................................................................ 7-7
7–3 Show Config .......................................................................................... 7-8
7–4 Show Device ........................................................................................ 7-16
7–5 Show Memory...................................................................................... 7-18
7–6 Defining Soft Partitions ...................................................................... 7-24
7–7 Defining Hard Partitions .................................................................... 7-26
8–1 Dial-In Configuration.......................................................................... 8-24
8–2 Alert Dial-Out Configuration.............................................................. 8-26
Figures
1–1 AlphaServer GS160 and GS80 Systems................................................ 1-2
1–2 Sample System Architecture................................................................. 1-5
2–1 System Box............................................................................................ 2-2
2–2 System Box Block Diagram (16-Processor System) .............................. 2-4
2–3 System Box Block Diagram (8-Processor System) ................................ 2-5
2–4 System Box QBBs (Top View) ............................................................... 2-6
2–5 Backplane (System Box, Front View).................................................... 2-8
2–6 CPU Module........................................................................................ 2-10
2–7 Memory Module .................................................................................. 2-11
2–8 Directory Module................................................................................. 2-12
2–9 Power Modules .................................................................................... 2-13
2–10 Power System Manager Module.......................................................... 2-14
2–11 Clock Splitter Module ......................................................................... 2-15
2–12 I/O Riser Module ................................................................................. 2-16
ix
2–13 Global Port Module ............................................................................. 2-17
2–14 Distribution Board .............................................................................. 2-18
2–15 Distribution Board in Single-Box System........................................... 2-19
2–16 Hierarchical Switch............................................................................. 2-20
2–17 Power System...................................................................................... 2-22
2–18 AC Input Box....................................................................................... 2-24
2–19 PCI Master Box................................................................................... 2-26
2–20 Control Panel ...................................................................................... 2-28
2–21 Control Panel LED Status .................................................................. 2-30
3–1 GS160 System ....................................................................................... 3-2
3–2 GS320 System ....................................................................................... 3-4
3–3 Power Cabinet Configuration (32-P System) ........................................ 3-6
3–4 Power Supply Slot Assignments ........................................................... 3-8
3–5 System Box QBB (Cabinet Front)....................................................... 3-10
3–6 System Box QBB (Cabinet Rear) ........................................................ 3-11
3–7 QBB Center Bar Color Code (Cabinet Front)...................................... 3-12
3–8 QBB Center Bar Color Code (Cabinet Rear)....................................... 3-13
3–9 Memory Module and Directory Module .............................................. 3-14
3–10 Sample I/O Subsystem ........................................................................ 3-18
3–11 PCI Slot Locations............................................................................... 3-20
3–12 BA356 Storage Device Configurations................................................ 3-22
4–1 System Drawer...................................................................................... 4-2
4–2 Two-Drawer Block Diagram.................................................................. 4-4
4–3 System Drawer Modules ....................................................................... 4-6
4–4 System Drawer Backplane.................................................................... 4-7
5–1 Rack....................................................................................................... 5-2
5–2 Rack Optional Configurations............................................................... 5-3
5–3 Two-Drawer Rack Power System.......................................................... 5-4
8–1 CSB Block Diagram .............................................................................. 8-2
8–2 Data Flow in Through Mode ................................................................. 8-6
8–3 Data Flow in Bypass Mode.................................................................... 8-8
8–4 Setups for SCM (PCI Box).................................................................. 8-11
Tables
1 AlphaServer 80/160/320 Family Documentation .................................. xiv
2–1 System Box Characteristics .................................................................. 2-2
2–2 Power Cabinet and System Environmental Characteristics ................ 2-3
2–3 AC Input Box Circuit Breakers........................................................... 2-25
3–1 Interleaving Memory Modules............................................................ 3-16
3–2 PCI Slots and Logical Hoses ............................................................... 3-21
x
4–1 System Drawer Characteristics ............................................................ 4-2
4–2 Rack System Characteristics ................................................................ 4-3
6–1 OpenVMS Boot Flag Settings ............................................................. 6-13
7–1 Summary of SRM Commands............................................................... 7-2
7–2 Notation Formats for SRM Console Commands ................................... 7-4
7–3 Special Characters for SRM Console ................................................... 7-5
7–4 Device Naming Conventions............................................................... 7-17
7–5 SRM Environment Variables for Soft Partitions ................................ 7-23
7–6 SCM Environment Variables for Hard Partitions .............................. 7-26
8–1 SCM Commands.................................................................................. 8-14
8–2 Status Command Fields...................................................................... 8-18
8–3 Elements of Dial String and Alert String ........................................... 8-28
8–4 SCM Troubleshooting.......................................................................... 8-30
A–1 PCI Backplane Jumpers........................................................................A-1
A–2 HPM Jumpers .......................................................................................A-2
A–3 Standard I/O Module Jumpers..............................................................A-2
xi
Preface
Intended Audience
This manual is for managers and operators of Compaq AlphaServer 80/160/320
family systems.
Document Structure
This manual uses a structured documentation design. Topics are organized into
small sections, usually consisting of two facing pages. Most topics begin with an
abstract that provides an overview of the section, followed by an illustration or
example. The facing page contains descriptions, procedures, and syntax
definitions.
This manual has eight chapters, an appendix, and glossary.
• Chapter 1, Introduction, gives a general overview of the AlphaServer
80/160/320 family.
• Chapter 2, GS160/320 System Overview, describes the components of
the GS160 and GS320 systems.
• Chapter 3, GS160/320 System Configuration Rules,provides
configuration guidelines for the GS160 and GS320 systems.
• Chapter 4, GS80 Rack System Overview, describes the components of
the GS80 rack system.
• Chapter 5, GS80 Rack System Configuration Rules,provides
configuration guidelines for the GS80 system.
• Chapter 6, Booting and Installing an Operating System, tells how to
boot a supported operating system and how to set boot options.
• Chapter 7, Operation, gives basic operating instructions.
• Chapter 8, Using the System Control Manager, describes the function
and operation of the system control manager.
xii
• Appendix A, Jumpering Information, calls out jumpers and their
functions.
Documentation Titles
Table 1 AlphaServer 80/160/320 Family Documentation
Order Number Title
QA–6GAAA–G8 AlphaServer GS80/160/320 Documentation Kit
EK–GS320–UG AlphaServer GS80/160/320 User’s Guide
EK–GS320–RM AlphaServer GS80/160/320 Firmware Reference Manual
EK–GSPAR–RM AlphaServer GS80/160/320 Getting Started with Partitions
EK–GS320–IN AlphaServer GS160/320 Installation Guide
EK–GSR80–IN AlphaServer GS80 Installation Guide
AG–RKSWB–BE AlphaServer GS80/160/320 User Information CD (HTML files)
AG–RLVJA–BE AlphaServer GS80/160/320 User Information CD (translations)
QA–6GAAB–G8 AlphaServer GS80/160/320 Service Documentation Kit
EK–GS320–SV AlphaServer GS80/160/320 Service Manual
EK–GS320–RM AlphaServer GS80/160/320 Firmware Reference Manual
AG–RKSZ*–BE AlphaServer GS80/160/320 Service Information CD
EK–GSCON–IN AlphaServer GS80/160/320 System Management Console
Installation and User’s Guide
EK–GS320–UP AlphaServer GS160/320 Upgrade Manual
EK–GSR80–UP AlphaServer GS80 Upgrade Manual
EK–GS320–SP AlphaServer GS80/160/320 Site Preparation
Information on the Internet
Visit the Compaq Web site at www.compaq.com/alphaserver/
site_index.html for service tools and more information about the
AlphaServer GS80/160/320 family systems.
Introduction 1-1
Chapter 1
Introduction
The Compaq AlphaServer GS160/320 and GS80 systems are high-performance
server platforms designed for enterprise-level applications. They offer a high
degree of scalability and expandability.
The GS160/320 system uses up to four Alpha microprocessors in each quad
building block (QBB). Two QBBs are paired back-to-back and rotated 180
degrees with reference to each other and then enclosed in a system box. A
system cabinet can hold up to two system boxes.
The GS80 rack system uses up to four Alpha microprocessors in a drawer. Each
rack holds up to two system drawers.
This chapter introduces the AlphaServer GS160/320 and AlphaServer GS80
systems. There are three sections:
• AlphaServer GS160/320 and GS80 Systems
• Firmware and Utilities Overview
• System Architecture
NOTE: When you unpack your system, be sure to save and store all shipping
brackets, pallets, and packing material. You will need this material to
repack the system, if you should decide to relocate it.
1-2 AlphaServer GS80/160/320 User's Guide
1.1 AlphaServer GS160/320 and GS80 Systems
The AlphaServer GS160/320 system and GS80 rack system are separate,
but related, in that they use the same switch technology. The CPU
modules, memory modules, and power modules are also the same. In
the GS160/320 system, the modules are in a system box in a cabinet. In
theGS80racksystem,themodulesareinadrawer.
Figure 1–1 AlphaServer GS160 and GS80 Systems
PK-0654-00
GS160 System
GS80 System
Introduction 1-3
AlphaServer GS160/320 System
The AlphaServer GS160 system cabinet contains up to two system boxes
supporting a maximum of 16 CPU modules.
In an AlphaServer GS320 system, a second system cabinet is used to expand the
system (up to four system boxes containing a maximum of 32 CPU modules).
A power cabinet contains the power components, I/O boxes, and storage.
Additional I/O and storage can be housed in expander cabinets.
AlphaServer GS80 System
The AlphaServer GS80 rack system contains up to two system drawers, I/O, and
storage. Each system drawer supports up to four CPU modules, for a maximum
of eight CPUs per system. Power components are mounted at the bottom of the
rack cabinet.
An expander cabinet can be used to house additional I/O and storage.
System Management Console
The console device, called the system management console (SMC), is a Compaq
Deskpro PC, a DECserver 90M terminal server, and associated hardware and
software. For installation instructions and user information, see the
AlphaServer GS80/160/320 System Management Console Installation and
User’s Guide.
1-4 AlphaServer GS80/160/320 User's Guide
1.2 Firmware and Utilities Overview
Firmware residing in ROM on CPU and other modules in the system
provides commands for booting the operating system, testing devices
and I/O adapters, and other tasks useful in operating and maintaining
a running system. You type commands at the console device.
SRM Console
Systems running the Tru64 UNIX or OpenVMS operating systems are
configured from the SRM console, a command-line interface (CLI). From the
CLI you can enter commands to configure the system, view the system
configuration, and boot the system.
System Control Manager (SCM)
The SCM firmware allows the user to access the system remotely. In addition,
the SCM:
• Monitors and notifies the user of power or temperature alert conditions
• Controls initial system power-up
• Manages hard partitions
LFU (Loadable Firmware Update Utility)
You can boot this utility (with the SRM boot command) whenever you need to
update the SRM console firmware or I/O device firmware. The CD with the
AlphaServer firmware is updated periodically.
Introduction 1-5
1.3 System Architecture
Each QBB in a GS160/320 system and each QBB (system drawer) in a
GS80 system has a backplane and a switch supporting the CPU
modules, memory modules, and I/O riser modules. Figure 1–2 shows
twoQBBsinasingle-boxsystem.
Figure 1–2 Sample System Architecture
System Box
CPU
MEM
I/O GP
CPU CPU CPU
Switch
MEMMEMMEM
Distribution
Board
To PCI Boxes
To PCI Boxes
CPU
MEM
I/O GP
CPU CPU CPU
Switch
MEMMEMMEM
PK-0601A-98
The backplane of each QBB (GS160/320 systems) and drawer (GS80 rack
systems) contains the switch that interconnects the CPU modules, memory
modules, and I/O riser modules.
The global port and distribution board provide the interconnect for the QBBs.
In a two-box system, a hierarchical switch is used as the interconnect, in place
of the distribution board.
I/O riser modules connect the PCI boxes to the QBB backplane.
GS160/320 System Overview 2-1
Chapter 2
GS160/320 System Overview
Each system cabinet contains one or two system boxes. The system box houses
two quad building blocks, or QBBs. CPU modules, memory modules, power
modules, and I/O riser modules plug into the QBB backplane.
The power cabinet contains power components, PCI boxes, and storage shelves.
This chapter provides an overview of the system in these sections:
• System Characteristics
• System Box Architecture
• Quad Building Block (QBB) Components
• Power System
• PCI I/O
• Control Panel
2-2 AlphaServer GS80/160/320 User's Guide
2.1 System Characteristics
The illustration shows the BA51A-AA system box. Table 2–1 lists the
system box characteristics. Table 2–2 lists power cabinet and
environmental characteristics.
Figure 2–1 System Box
PK0611
Table 2–1 System Box Characteristics
Characteristic Specification
Size
535 mm H x 550 mm W x 475 mm D
(21.06 in. x 21.65 in. x 18.7 in.)
Weight 54.55 kg (120 lb) maximum
Maximum heat dissipation 2000 w (6,850 Btu/hr)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184

Compaq GS80 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI