Allied Telesis AT-PWR10 Installation guide

Type
Installation guide

Allied Telesis AT-PWR10 is an AC redundant power supply for the AT-8400 Series switch. When installed, the unit operates in a standby mode. If the standard power supply fails or loses power, the AT-PWR10 unit changes from standby to active and provides all power to the system to prevent a network failure. The AT-PWR10 unit must be installed in an AC powered AT-8400 Series switch. This type of chassis has two AC power sockets on the back panel. There may be several different models of AC power supplies for the AT-8400 Series switch. Each model is rated for a different power load.

Allied Telesis AT-PWR10 is an AC redundant power supply for the AT-8400 Series switch. When installed, the unit operates in a standby mode. If the standard power supply fails or loses power, the AT-PWR10 unit changes from standby to active and provides all power to the system to prevent a network failure. The AT-PWR10 unit must be installed in an AC powered AT-8400 Series switch. This type of chassis has two AC power sockets on the back panel. There may be several different models of AC power supplies for the AT-8400 Series switch. Each model is rated for a different power load.

Overview
The AT-PWR10 is an AC redundant power supply for the AT-8400 Series switch.
When installed, the unit operates in a standby mode. If the standard power supply
fails or loses power, the AT-PWR10 unit changes from standby to active and
provides all power to the system to prevent a network failure.
Note
The power supply is hot-swappable. You can install it without powering off
the AT-8400 Series switch.
AT-PWR10
AC
P
O
W
E
R
F
A
U
L
T
W
AR
NIN
G
BEFORE
EJECTING,
LOOSEN
THUMBSCREW
!
Related Documents
The Allied Telesyn web site at www.alliedtelesyn.com contains the most recent
documentation, software, and technical information on all of our products. For
details on the features and functions of your Allied Telesyn AT-8400 Series switch
and line cards, refer to the following manuals from our web site:
AT-8400 Series Switch Reference Guide
PN 613-50399-00
AT-S60 Management Software User’s Guide
PN 613-50400-00
AT-S60 Command Line User’s Guide
PN 613-50401-00
Package Contents
Make sure the following items are included in the shipping package. If any item is
missing or damaged, contact your Allied Telesyn sales representative for
assistance.
One AT-PWR10 Redundant Power Supply (AC)
Installation Guide
Warranty Card
The AC power cord for this power supply comes with the AT-8400 chassis.
Note
To replace a power supply, refer to the AT-8400 Series Switch Reference Guide
for instructions on how to remove a power supply from the chassis.
Installing the AT-PWR10 Power Supply
Before installing a power supply, please note the following:
Refer to the AT-8400 Series Switch Reference Guide for electrical safety and
emission information.
The AT-PWR10 unit must be installed in an AC powered AT-8400 Series
switch. This type of chassis has two AC power sockets on the back panel.
There may be several different models of AC power supplies for the
AT-8400 Series switch. Each model is rated for a different power load.
Both power supplies in an AT-8400 Series switch must be of the same
model type. Do not mix power supplies with different power ratings in
the same chassis.
To install the AT-PWR10 unit, follow these steps:
1. Using a Phillips screwdriver, loosen the two captive screws that secure the
power supply cover to the chassis and remove the cover. You remove the cover
by angling it from the bottom as you slide it down and out of the chassis.
2. Using a Phillips screwdriver, loosen the captive screw that secures the cover
over the power supply PWR B slot and slide the cover from the chassis.
Note
Store the cover in a safe place. You must reinstall it if you ever remove a power
supply from the chassis without installing a new one.
1
AT-8411
TX
E
J
E
C
T
L
N
K
1
0
A
CT
1
0
0
1
AT-84 11
TX
E
J
E
C
T
L
N
K
1
0
A
C
T
1
0
0
AT-PWR10
AC
P
O
W
E
R
F
A
U
L
T
AT-PWR10
AC
P
O
W
E
R
F
A
U
L
T
1
AT-84 11
TX
EJ
E
CT
L
NK
10
A
CT
100
2
3
AT-84 11
TX
EJ
E
CT
L
N
K
10
AC
T
100
AT-84 11
TX
EJ
E
CT
L
NK
10
ACT
100
WARN
I
N
G
BEFORE
EJECTING,
LOOSEN
THUMBSCREW
!
AT-PWR10
Redundant Power Supply (AC)
Installation Guide
Allied Telesyn, Inc.
960 Stewart Drive, Suite B
Sunnyvale, CA 94085 USA
Tel 1 (408) 730-0950 • Fax 1 (408) 736-0100
Visit our web site at: www.alliedtelesyn.com
PN 613-50394-00 Rev B
1 2 3
3. Place the locking levers on the new AT-PWR10 power supply in the released
position.
4. Slide the new AT-PWR10 power supply into the power supply slot until it makes
contact with the backplane of the chassis. Be sure that the labeling on the
power supply is right-side up. Also be sure to align the green board on the
power supply with the slots in the chassis. Once the power supply makes
contact with its connector on the backplane, press firmly to fully seat the power
supply on the power connector.
Note
If you are unable to slide the power supply completely into the slot, you may
have purchased the wrong type of power supply for the chassis. An AC
powered chassis has two AC power sockets on the back panel.
AT-PWR10
AC
P
O
W
E
R
F
A
U
L
T
W
A
R
NIN
G
BEFOR
E
EJECTING,
LOOSE
N
THUMB
SCREW
!
AT-PW
R1
0
AC
P
O
W
E
R
F
A
U
L
T
1
AT-8 411
TX
EJ
E
CT
L
NK
10
AC
T
100
2
3
AT-8 411
TX
EJ
E
CT
L
NK
10
AC
T
100
AT-8 411
TX
EJ
E
CT
L
NK
10
A
CT
100
AT-P W
R
1
0
AC
P
O
W
E
R
F
A
U
L
T
WARN
ING
BEFORE
EJECTING,
LOOSEN
THUMBSCREW
!
5. Move the locking levers on the AT-PWR10 unit into the locked position and
tighten the captive screw to secure the power supply in the chassis.
Note
Always use the locking levers and the installation screw to secure the power
supply to the switch. Leaving the power supply partially seated may cause the
system to halt and subsequently crash.
6. Connect an AC power cord to the POWER B power connector on the back panel
on the chassis and secure the cord by lowering the securing bracket.
7. Connect the other end of the power cord to an appropriate power source.
8. Check the POWER LED on the front of the power supply. It should be steady
green. If the LED remains off, reinstall the unit by repeating this procedure.
AT-PWR10
AC
P
O
W
E
R
F
A
U
L
T
AT-PWR11
DC
P
O
W
E
R
F
A
U
L
T
WARNING
BEFORE
EJECTING,
LOOSEN
THUMBSCREW
!
WARNING
BEFORE
EJECTING,
LOOSEN
THUMBSCREW
!
FAN A
PWR BPWR A
FAN A
PWR B PWR
A
WARNING
This unit might have more
than one power cord. To
reduce the risk of electric
shock, disconnect all
power cords before
servicing unit.
WARNING
This unit might
have more
than one power cord.
To
reduce the risk
of electric
shock,
disconnect all
power cords before
servicing
unit.
9. Slide the power supply cover back into the chassis and secure the cover by
tightening the two captive screws.
Technical Specifications
Power Specifications: 100-240V AC, 3A maximum, 50/60 Hz
Maximum Operating Temperature: 0° C to 40° C (32° F to 104° F)
Maximum Storage Temperature: -20° C to 80° C (-4° F to 176° F)
Operating and Storage Altitude: Up to 3,048 meters (10,000 feet)
Relative Humidity Operating
and Storage: 5% to 80% (non-condensing)
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
Emission FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK
WARNING: In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
Immunity EN55024
Electrical Safety UL60950 (UL/cUL), EN60950 (TUV)
Copyright 2003 Allied Telesyn, Inc. All rights reserved.
No part of this publication may be reproduced without prior written permission from Allied Telesyn Inc.
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to
operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
1
AT-8411
TX
EJECT
LNK
1
0
A
C
T
1
00
1
AT-8411
TX
EJEC
T
LNK
1
0
A
C
T
1
00
4 5 6
  • Page 1 1
  • Page 2 2

Allied Telesis AT-PWR10 Installation guide

Type
Installation guide

Allied Telesis AT-PWR10 is an AC redundant power supply for the AT-8400 Series switch. When installed, the unit operates in a standby mode. If the standard power supply fails or loses power, the AT-PWR10 unit changes from standby to active and provides all power to the system to prevent a network failure. The AT-PWR10 unit must be installed in an AC powered AT-8400 Series switch. This type of chassis has two AC power sockets on the back panel. There may be several different models of AC power supplies for the AT-8400 Series switch. Each model is rated for a different power load.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI