WaterFurnace NSZ Installation guide

Category
Heat pumps
Type
Installation guide

This manual is also suitable for

Installation Information
Water Piping Connections
Hot Water Generation Connections
Electrical
Startup Procedures
Troubleshooting
Preventive Maintenance
IM1003SN 08/10
NSZ/NDZ Indoor Split Installation Manual
Geothermal/Water Source Indoor Split Heat Pump
2 to 6 Tons Single Speed
2 to 6 Tons Dual Capacity
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Table of Contents
Model Nomenclature 4
Physical Characteristics  4
Physical Dimensions  5
General Installation Information  6-9
Physical Data - Envision Air Handler  9
Open Loop - Well Water Systems  10-11
Water Quality 11
Closed Loop - Ground Source Systems 12
Hot Water Generator Connections 13-14
Electrical Data 15
Thermostat Wiring 15
Wiring Schematics16-17
Microprocessor Control 18-21
Operation Logic Data                                                          22
DIP Switch Settings 22
Refrigeration  23-25
Line Set Sizes  25
Pressure/Temperature Conversion Chart for R-410A 26
Thermistor Resistance  27
Operating Parameters27-28
Pressure Drop and Recommended Flow Rates 29
Unit Startup and Troubleshooting  30-32
Preventative Maintenance  33
Replacement Procedures  33
Service Parts List 34
4
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Model Nomenclature
1 2 3 4-6 7 8 9 10 11
ND Z 049 A 1 1 A C
Model Type
N = Envision Coax Options
C = Copper
Compressor Type N = Cupronickel
D = Dual Capacity
S = Single Speed Future Option
A = Standard
Cabinet Configuration
Z = Indoor Split Hot Water Option
0 = No Hot Water Generator,
No IntelliStart
1 = Hot Water Generator with
factory installed pump,
No IntelliStart
3 = No Hot Water Generator,
IntelliStart
4 = Hot Water Generator with
factory installed pump,
IntelliStart
Unit Capacity
Vintage
A = Current
Voltage
1 = 208-230/60/1
Physical Characteristics
Model 022 030 036 042 048 060 070 026 038 049 064 72
Compressor (1 each) Single Speed Scroll Dual Capacity Scroll
Factory Charge R410a, oz [kg] 5 6
[1.59]
5 6
[1.59]
5 6
[1.59]
7 4
[2.1]
9 0
[2.55]
9 2
[2.61]
1 0 8
[3.06]
5 2
[1.47]
5 6
[1.59]
9 0
[2.55]
9 2
[2.61]
104
[2.95]
Coax and Water Piping
Water Connections Size - Swivel- in [mm] 1 [25.4] 1 [25.4]
HWG Connection Size - Swivel - in [mm] 1 [25.4] 1 [25.4]
Brass Service Valve - Liquid Line - in [mm] 3 /8
[9.525]
1/2
[12.7]
3/8
[9.525]
1/2
[12.7]
Brass Service Valve - Suction Line - in [mm] 5/8
[15.875]
3/4
[19.05]
7/8
[22.225]
5 / 8
[15.875]
3/4
[19.05]
7/ 8
[22.225]
Coax and Piping Water Volume - gal [l] 0 . 7
[2.6]
1 . 0
[3.8]
1 . 3
[4.9]
1 . 3
[4.9]
1 . 6
[6.1]
1 . 6
[6.1]
2 . 3
[8.7]
0 . 7
[2.6]
1 . 3
[4.9]
1 . 6
[6.1]
1 . 6
[6.1]
2 . 3
[8.7]
Weight - Operating, lb [kg] 1 6 4
[74]
1 7 4
[79]
21 2
[96]
2 1 3
[97]
2 4 6
[112]
2 5 1
[114]
2 9 2
[132]
189
[186]
2 3 6
[107]
2 5 0
[113]
2 7 1
[123]
2 9 0
[132]
Weight - Packaged, lb [kg] 1 8 4
[83]
1 9 4
[88]
2 3 2
[105]
2 3 3
[106]
2 6 6
[121]
2 7 1
[123]
3 1 2
[142]
2 0 9
[95]
2 5 6
[116]
2 7 0
[122]
2 9 1
[132]
3 10
[141]
10/29/08
NOTES: All units have TXV expansion devices, and 1/2 in. [12.2 mm] and 3/4 in. [19.1 mm] electrical knockouts.
Brass service valves are sweat type valves.
5
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Physical Dimensions
Dimensions are in inches.
Decorative molding and water connections extend 1.2 in. [30.5 mm] beyond the front of the cabinet.
Refrigerant line connections extend 2 in. [50.8 mm] beyond the front of the cabinet.
Model
Height Width Depth Water In Water Out
Service Valve
HWG In HWG Out Low
Voltage
External
Pump
Line
Voltage
Liquid Gas
A B C D E F G H J K L M
022-030 19.25 22.50 26.50 1.93 6.93 8.44 11.55 13.43 16.43 8.55 10.30 11.80
038-072 21.25 25.50 31.50 2.21 7.21 9.21 12.14 15.83 18.83 7.7 1 9.46 10.96
A
C
B
D
EF
G
H
J
K
L
M
6
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Installing and servicing heating and air conditioning
equipment can be hazardous due to system pressure and
electrical components. Only trained and qualified service
personnel should install, repair or service heating and air
conditioning equipment. Untrained personnel can perform
the basic maintenance functions of cleaning coils and
cleaning and replacing filters. All other operations should be
performed by trained service personnel. When working on
heating and air conditioning equipment, observe precautions
in the literature, tags and labels attached to the unit and
other safety precautions that may apply, such as the
following safety measures:
Follow all safety codes.
Wear safety glasses and work gloves.
Use a quenching cloth for brazing operations.
Have a fire extinguisher available for all brazing operations.
Moving and Storage
Move units in the normal “up” orientation. Units may be
moved and stored per the information on the packaging.
Do not stack more than three units in total height. Do not
attempt to move units while stacked. When the equipment
is received, all items should be carefully checked against
the bill of lading to be sure all crates and cartons have been
received. Examine units for shipping damage, removing
the units from the packaging if necessary. Units in question
should also be internally inspected. If any damage is noted,
the carrier should make the proper notation on the delivery
receipt, acknowledging the damage.
Unit Location
Locate the unit in an indoor area that allows for easy
removal of the access panels. Location should have enough
space for service personnel to perform maintenance or
repair. Provide sufficient room to make water, electrical and
refrigerant line connections. Any access panel screws that
would be difficult to remove after the unit is installed should
be removed prior to setting the unit. Care should be taken
when units are located in unconditioned spaces to prevent
damage from frozen water lines and excessive heat that
could damage electrical components.
Air Coil Location
Refer to the air handler manufacturer’s instructions for the
blower coil unit for details on installing the air handling
portion of the system.
Condensate Drain
Follow the blower coil manufacturer’s instructions.
WARNING: Before performing service or
maintenance operations on a system, turn off main
power switches to the indoor unit. If applicable,
turn off the accessory heater power switch.
Electrical shock could cause personal injury.
Safety Considerations Duct System
All blower coil units/air coils must be installed as specified
by the manufacturer’s installation instructions; however,
the following recommendations should be considered to
minimize noise and service problems.
An air filter must always be installed upstream of the air coil
on the return air side of the air handler or furnace. If there
is limited access to the filter rack for normal maintenance, it
is suggested that a return air filter grill be installed. Be sure
that the return duct is properly installed and free of leaks
to prevent dirt and debris from bypassing the filter and
plugging the air coil.
In applications using galvanized metal ductwork, a flexible
duct connector is recommended on both the supply and
return air plenums to minimize vibration from the blower. To
maximize sound attenuation of the unit blower, the supply
and return plenums should include an internal duct liner
of 1-inch thick glass fiber or be constructed of ductboard.
Insulation is usually not installed in the supply branch ducts.
Ducts in unconditioned areas should be wrapped with a
minimum of 1-inch duct insulation. Application of the unit
to uninsulated ductwork in an unconditioned space is not
recommended as the unit’s performance will be adversely
affected. If the air handler is connected to existing ductwork,
a previous check should have been made to assure that the
duct system has the capacity to handle the air required for
the unit application. If ducting is too small, as in replacement
of heating only systems, larger ductwork should be installed.
All existing ductwork should be checked for leaks and
repairs made accordingly. The duct systems and diffusers
should be sized to handle the design airflow quietly. If air
noise or excessive airflow is a problem, the blower speed
can be changed to a lower speed to reduce airflow. This
will reduce the performance of the unit slightly in heating;
however, it will increase the temperature rise across the air
coil. Airflow must still meet minimum requirements.
Equipment Selection
The following guidelines should be used when mating an
Envision Split to an air handler/coil.
Select R-410A components only.
Select 13 SEER or higher air handler/coil.
Match the air handler to the air handler coil data table.
Indoor matching adjustable TXV should be used with
any air handler/coil. Fixed orifice or cap tube systems
should not be used.
Utilizing Existing Coil or Air Handler
It is recommended that a new R-410A air handler be
installed with an Envision Split considering the long term
benefits of reliability, warranty, etc. versus the short term
installation cost savings. However, the existing air handler
may be retained provided the following:
Coil currently is R-410A rated
Coil uses a TXV. No capillary or fixed orifice systems
should be used
General Installation Information
7
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
A life expectancy of more than 7 years remaining for the
air handler and components
Flush air coil and line set
When utilizing the existing air coil or line set, only flushing
compounds that vaporize should be used; which means
they are packaged in a pressurized disposable cylinder. It is
preferable to use a flushing agent that removes oil, water,
and acid, plus, is biodegradeable and non-toxic. The flushing
agent should be safe to use with both HCFC and HFC
refrigerants. Once a flushing agent has been selected, follow
the instructions provided with the product.
The first step should be purging the lines or air coil with
nitrogen. Purging with nitrogen first will remove some of
the particulate and residual oil which will allow the flushing
agent to work better. Never blow the flushing agent
through a compressor, filter drier, or txv as it will cause the
components to fail.
When flushing is complete and the final system is assembled,
an acid check should be preformed on the system. Acid test
kits are available from most HVACR distributors.
Connection to Air Coil
Figures 1 and 2 illustrate typical Envision Split installations.
Reference the Line Set Sizes table for typical line set
diameters and maximum length. Line sets over 60 feet are
not recommended. Longer line sets will significantly reduce
capacity and efficiency of the system as well as adversely
effect the system reliability due to poor oil return. If the
line set is kinked or deformed and cannot be reformed, the
bad section of pipe should be replaced. A restricted line set
will affect unit performance. As in all R-410A equipment,
a reversible liquid line filter drier is required to insure all
moisture is removed from the system. This drier should be
replaced whenever “breaking into” the system for service. All
line sets should be insulated with a minimum of 1/2 in. closed
cell insulation. All exterior insulation should be painted with
UV resistant paint or covering to ensure long insulation life.
Air Handler Installation
Air handlers used with dual capacity units must be capable
of operating with a minimum of 2 blower speeds. Refer to
the manufacturers instructions for the blower coil unit for
details on installing the air handling portion of the system.
All blower coil units/air coils must be installed as specified
by the manufacturers installations instructions. However,
the following recommendations should be considered to
minimize noise and service problems.
An air filter must always be installed upstream of the air coil
on the return air side of the air handler or furnace. If there
is limited access to the filter rack for normal maintenance,
it is suggested that a return air filter grille be installed. Be
sure that the return duct is properly installed and free of
leaks to prevent dirt and debris from bypassing the filter and
plugging the air coil.
Ensure that the line set size is appropriate to the capacity of
the unit (refer to Line Set Sizes table). Line sets should be
routed as directly as possible, avoiding unnecessary bends
or turns. All wall penetrations should be sealed properly. Line
set should not come into direct contact with water pipes,
floor joists, wall studs, duct work, floors, walls and brick.
Line set should not be suspended from joists or studs with a
rigid wire or strap which comes into direct contact with the
tubing. Wide hanger strips which conform to the shape of
the tubing are recommended. Isolate hanger straps from line
set insulation by using metal sleeves bent to conform to the
shape of insulation. Line set insulation should be pliable, and
should completely surround the refrigerant line.
NOTES: Improper installation of equipment may result in
undesirable noise levels in the living areas.
Disconnect
Thermostat Wire
From Air Handler
Vibration Absorbing Pad or Air Pad
P/T Plugs
Water Out
Water In
Lineset To Air Handler
Insulated Suction Line
Supply
Duct
Wire To
Thermostat
Return
Duct
Condensate Drain
(must be trapped)
To Drain
Remote Air Handler
(Maximum Recommended Distance is
60' Between Units)
DHW In
DHW Out
Figure 1: Typical Split System Application with
Remote Blower Coil
General Installation Information cont.
8
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Dual Fuel Systems
Envision units can be connected to fossil fuel furnaces that
include an A-coil or slab coil. Dual fuel installations utilize
the Envision heat pump for heating until the point that aux-
iliary heat is called for on the thermostat. At that point, the
furnace will be enabled and the heat pump will be disabled.
The Envision heat pump provides air conditioning through
the furnace’s refrigerant coils.
Refer to the furnace manufacturer’s installation manual
for the furnace installation, wiring and coil insertion. A
WaterFurnace Dual Fuel thermostat, a field-installed DPST
relay or dual capacity auxiliary heat relay is required. See
Figure 2 for typical Dual Fuel application.
Disconnect
Thermostat
Wire From Furnace
Vibration Absorbing Pad or Air Pad
P/T Plugs
Wire To
Thermostat
Up-Flow
Fossil Fuel
Furnace
Condensate
Drain
(must be trapped)
"A" or
Slab Coil
Supply Duct
Air Temperature Limit Switch -
to prevent compressor operation
when entering air is greater than
90°F.
Water Out
Water In
Lineset To Air Handler
Insulated
Suction Line
DHW In
Return
Duct
DHW Out
Maximum Recommended Distance
is 60' Between Units
Figure 2: Typical Split System Heat Pump Coil Add-On
Fossil Fuel Furnace
In add-on Envision Split applications, the coil should be
located in the supply side of the furnace to avoid con-
densation damage to the furnace heat exchanger. A high
temperature limit should be installed upstream of the coil
to de-energize the compressor whenever the furnace is
operating. Without this switch, the Envision Split will trip
out on high pressure. A dual fuel thermostat can remove
the Y1 and Y2 calls when a W call is energized to allow gas
furnace backup on an Envision Split application. Refer to
thermostat wiring diagram for details.
General Installation Information cont.
9
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Water Piping
The proper water flow must be provided to each unit
whenever the unit operates. To assure proper flow, use
pressure/temperature ports to determine the flow rate.
These ports should be located at the supply and return
water connections on the unit. The proper flow rate cannot
be accurately set without measuring the water pressure
drop through the refrigerant-to-water heat exchanger.
All source water connections on residential units are
swivel piping fittings (see Figure 3) that accept 1 in. male
pipe threads (MPT). The swivel connector has a rubber
gasket seal similar to a rubber hose gasket, which when
mated to the flush end of any 1 in. threaded pipe provides
a leak-free seal without the need for thread sealing tape
or compound. Check to ensure that the rubber seal is in
the swivel connector prior to attempting any connection.
The rubber seals are shipped attached to the waterline.
To make the connection to a ground loop system, mate
the brass connector (supplied in CK4L connector kit)
against the rubber gasket in the swivel connector and
thread the female locking ring onto the pipe threads, while
maintaining the brass connector in the desired direction.
Tighten the connectors by hand, then gently snug the
fitting with pliers to provide a leak-proof joint. When
connecting to an open loop (ground water) system, thread
the 1 in. MPT fitting (SCH80 PVC or copper) into the swivel
connector and tighten in the same manner as noted above.
The open and closed loop piping system should include
pressure/temperature taps for serviceability.
Locking
Ring
Stainless
Steel
Snap Ring
Gasket
Support
Sleeve
Gasket
Material
Figure 3: Swivel Connections
(Residential Units)
General Installation Information cont.
Never use flexible hoses smaller than 1 in. inside diameter
on the unit. Limit hose length to 10 ft. per connection.
Check carefully for water leaks.
Air Handler Sizing Selection
The Envision Air Handlers are designed for R410a refrigerant and should be matched with Envision Split series compressor
section according to the table below.
Air Handler Indoor Split Model
(Single)
Indoor Split Model
(Dual Capacity)
Outdoor Split Model
(Dual Capacity) Airow(CFM) Electric Heat (kW)
NAH022A***1R NSZ022 - 800 5
NAH026A***1R - NDZ026 NDS026 925 5
NAH030A***1R NSZ030 - - 980 5, 10
NAH036A***1R NSZ036 - - 1225 5, 10
NAH036A***1R - NDZ038 NDS038 1225 5, 10
NAH042A***1R NSZ042 - - 1425 10, 15
NAH048A***1R NSZ048 - - 1625 10, 15
NAH048A***1R - NDZ049 NDS049 1625 10, 15
NAH060A***1R NSZ060 - - 1760 10, 15, 20
NAH060A***1R - NDZ064 NDS064 1760 10, 15, 20
NAH060A***1R NSZ070 - - 1760 10, 15, 20
NAH060A***1R - NDZ072 NDS072 1760 10, 15, 20
6/9/08
10
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Typical open loop piping is shown below. Always maintain
water pressure in the heat exchanger by placing water
control valves at the outlet of the unit to prevent mineral
precipitation. Use a closed bladder type expansion tank
to minimize mineral formation due to air exposure. Ensure
proper water flow through the unit by checking pressure
drop across the heat exchanger and comparing it to the
figures in the unit capacity data tables in the specification
catalog. Usually 1.5-2 GPM of flow per ton of cooling
capacity is recommended in open loop applications. In
dual capacity units, stage 1 is 70% of the total tonnage.
Therefore, due to only minor differences in flow rate from
low to high, only one solenoid valve should be used. The
valve should be sized for full flow.
Figure 4: Typical Split System Application Open Loop - Well Water
Disconnect
Thermostat Wire
From Air Handler
Vibration Absorbing Pad or Air Pad
P/T Plugs
Boiler Drains for
System Flushing
Water Solenoid
Control Valve
Rubber Bladder
Pressure Tank
Lineset
T o Air Handler
Flow
Regulator
Shut-Off Valves
Water Out
Water In
From W ell
Acc Com
Acc NC
Acc NO
1
2
3
C
R
P3
SV
Solenoid
Valve
CC-GND
CC
CCHI
Comfort
Alert
Y1
Y2
Logic Board
Violet(3)
Blk(1)
Wht(4)
VM valve
Violet(2)
CC
SV
Figure 9b: Open Loop Solenoid Valve Connection Option
Typical slow operating external 24V water solenoid valve
(type VM) wiring.
Figure 5: Open Loop Solenoid Valve Connection Option
Typical quick operating external 24V water solenoid valve
(type PPV100 or BPV100) wiring.
Open Loop - Well Water Systems
Discharge water from the unit is not contaminated in any
manner and can be disposed of in various ways depending
on local building codes (i.e. recharge well, storm sewer,
drain field, adjacent stream or pond, etc.). Most local codes
forbid the use of sanitary sewer for disposal. Consult
your local building and zoning departments to ensure
compliance in your area.
NOTES: For open loop/groundwater systems or systems
that do not contain an antifreeze solution, set SW2-
Switch #2 to the “WELL” position (Refer to the DIP Switch
Settings table.) Slow opening/closing solenoid valves (type
VM) are recommended to eliminate water hammer.
11
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Solenoid Wiring
Water control valves draw their power directly from a unit’s
24V transformer and can overload and possibly burn out
the transformer. Check total VA draw of the water valve
and ensure that it is under 15 VA.
Open Loop - Well Water Systems cont.
In ground water situations where scaling could be heavy
or where biological growth such as iron bacteria will be
present, a closed loop system is recommended. The heat
exchanger coils in ground water systems may, over a period
of time, lose heat exchange capabilities due to a buildup
of mineral deposits inside. These can be cleaned, but only
by a qualified service mechanic, as special solutions and
Water Quality
pumping equipment are required. Hot water generator coils
can likewise become scaled and possibly plugged. In areas
with extremely hard water, the owner should be informed
that the heat exchanger may require occasional flushing.
Failure to adhere to the guidelines in the water quality table
could result in loss of warranty.
Note:
Grains = PPM divided by 17
mg/l is equivalent to PPM
leetS sselniatS 613lekciN-orpuC 01/09reppoClairetaM
pH Acidity/Alkalinity 9 - 7 9 - 7 9 -7
Scaling Calcium and Magnesium Carbonate (Total Hardness) less than 350 ppm (Total Hardness) less than 350 ppm (Total Hardness) less than 350 ppm
Hydrogen Sulfide
Less than .5 ppm (rotten egg smell
appears at 0.5 PPM)
mpp 1 naht sseLmpp 05 - 01
mpp 002 naht sseLmpp 521 naht sseLmpp 521 naht sseLsetafluS
mpp 5. naht sseLmpp 5. naht sseLmpp 5. naht sseLenirolhC
mpp 003 naht sseLmpp 521naht sseLmpp 02 naht sseLsedirolhC
mpp 05 -01mpp 05 - 01mpp 05 naht sseLedixoiD nobraC
mpp 02 naht sseLmpp 2 naht sseLmpp 2 naht sseLainommA
Corrosion mpp 5. naht sseLmpp 5. naht sseLmpp 5. naht sseLedirolhC ainommA
mpp 5. naht sseLmpp 5. naht sseLmpp 5. naht sseLetartiN ainommA
mpp 5. naht sseLmpp 5. naht sseLmpp 5. naht sseLedixordyH ainommA
mpp 5. naht sseLmpp 5. naht sseLmpp 5. naht sseLetafluS ainommA
mpp 0051-0001mpp 0051-0001mpp 0001 naht sseL)SDT( sdiloS devlossiD latoT
LSI Index +0.5 to -.05 +0.5 to -.05 +0.5 to -.05
Iron Fouling
Bacterial Iron Potential
mpp 2. < mpp 2. < mpp2. <
(Biological Growth)
Iron Oxide Less than 1 ppm. Above this level
deposition will occur.
Less than 1 ppm. Above this level
deposition will occur.
Less than 1 ppm. Above this level
deposition will occur.
Erosion Suspended Solids Less than 10 ppm and filtered for max of
600 micron size
Less than 10 ppm and filtered for max of
600 micron size
Less than 10 ppm and filtered for max of
600 micron size
ces/tf 6<ces/tf 6 <ces/tf 6 < )retaW hserF( yticoleV dlohserhT
12
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
NOTE: For closed loop systems with antifreeze protection, set
SW2-2 to the “loop” position (see DIP Switch Settings table).
Once piping is completed between the unit, pumps and the
ground loop (see figure below), final purging and charging
of the loop is required. A flush cart (or a 1.5 HP pump
minimum) is needed to achieve adequate flow velocity
in the loop to purge air and dirt particles from the loop
itself. Antifreeze solution is used in most areas to prevent
freezing. Flush the system adequately to remove as much
air as possible then pressurize the loop to a static pressure
of 40-50 PSI (summer) or 50-75 PSI (winter). This is
normally adequate for good system operation. Loop static
pressure will fluctuate with the seasons. Pressures will be
higher in the winter months
than during the cooling season.
This fluctuation is normal and
should be considered when
initially charging the system.
After pressurization, be sure
to remove the plug in the end
of the loop pump motor(s) (if
applicable) to allow trapped air
to be discharged and to ensure
that the motor housing has been
flooded. Ensure that the loop
pumps provide adequate flow
through the unit(s) by checking
the pressure drop across the
heat exchanger and comparing
it to the unit capacity data
in the specification catalog.
Usually 2.5 to 3 GPM of flow
per ton of cooling capacity is
recommended in earth loop
applications.
Figure 7: Typical Split System Application Closed Loop - Earth Coupled
Disconnect
Thermostat Wire
From Air Handler
Vibration Absorbing Pad or Air Pad
P/T Plugs
Lineset
To Air
Handler
Insulated
Flow Center
Electrical Supply
GeoLink
Flow Center
To Loop
DHW Out
Rubber Hose Connector
Kit CK4L or CK4S
DHW In
Envision to
Electromechanical Units
Shut
Down CC
SL1
In
SL1
Out
Envision Unit #1
To Electromechanical Unit
CS
Shut
Down CC
Shut
Down CC
SL1
In
SL1
Out
SL1
In
SL1
Out
Single Speed
Envision Unit #1
With pump
wired to Unit 1
With pump
wired to
Unit 2
Envision to Envision
Microprocessor Units
Envision Unit #2
Single Speed
With pump
wired to Unit 1
With pump
wired to
Unit 2
Shut
Down CC
Shut
Down CC
SL1
In
SL1
Out
SL1
In
SL1
Out
Dual Capacity
Envision Unit #1
Envision Unit #2
Dual Capacity
Envision to Envision
Microprocessor Units
Figure 8: Primary/Secondary Hook-up
Closed Loop - Ground Source Systems
Multiple Units on One Flow Center
When two units are connected to one loop pumping
system, pump control is automatically achieved by
connecting the SL terminals on connector P2 in both units
with 2-wire thermostat wire. These terminals are polarity
dependant (see Figure 8). The loop pump(s) may be
powered from either unit, whichever is more convenient. If
either unit calls, the loop pump(s) will automatically start.
The use of two units on one flow center is generally limited
to a total of 20 GPM capacity.
13
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Figure 11: Hot Water Generator Installation
in Preheat Tank
Figure 10: Typical Hot Water Generator Installation
Drain Va lve
In
P/T Relief
Va lve
Cold
Wa ter In
Hot
Wa ter Out
DHW
Wa ter In
DHW
Wa ter Out
Venting Waste Va lve
or Vent Coupling
3/4˝ x 3/4˝ x 1/2˝ tee
Drain Valve Drain Valve
In
P/T Relief
Valve
Venting Waste Valve
or Vent Coupling
DHW
DHW
3/4˝ x 3/4˝ x 1/2˝ tee
Water In
Hot
Water Out
Cold
Water In
Water Out
P/T Relief
Valve
The heat reclaiming hot water generator coil is vented
double-wall copper construction and is suitable for potable
water. To maximize the benefits of the hot water generator
a minimum 50-gallon water heater is recommended. For
higher demand applications, use an 80-gallon water heater
or two 50-gallon water heaters connected in a series as
shown below. A geo storage tank should not be used in this
application unless it is plumbed in a series with an electric
water heater. The geo storage tank is equipped with a
single 4500 Watt element and will not be able to provide
adequate water heating if used as a standalone water
heater. Electric water heaters are recommended. Make sure
all local electrical and plumbing codes are followed when
installing a hot water generator. Residential units with hot
water generators contain an internal circulator and fittings. A
water softener is recommended for hard water applications
(greater than 10 grains or 170 ppm total hardness).
CAUTION: Elements will burn out if energized dry.
Water Tank Preparation
To install a unit with hot water generator, follow these
installation guidelines.
Turn off the power to the water heater.1.
Attach a water hose to the water tank drain connection 2.
and run the other end of the hose to an open drain or
outdoors.
Close the cold water inlet valve to the water heater 3.
tank.
Drain the tank by opening the valve on the bottom 4.
of the tank, then open the pressure relief valve or hot
water faucet.
Hot Water Generator Connections
NOTE: Under certain conditions, Envision dual capacity
units operate with very low refrigerant discharge
temperatures, producing little or no water heating
capability. This scenario occurs when the unit is operating
with cold entering source water (loop or well). Allowing
the hot water generator pump to operate during
these conditions actually removes heat from the DHW
circulating through the unit. To overcome this, Envision unit
microprocessors have been programmed to disengage the
hot water generator pump during such conditions. (During
low capacity cooling operation, the pump will operate only
if the DHW temperature entering the unit is less than the
liquid line temperature plus 35° F. During high capacity
cooling operation, the pump will operate only if the DHW
temperature is less than the liquid line temperature plus
60°F.) Using a preheat tank, as shown in Figure 11, will
maximize hot water generator capabilities.
Flush the tank by opening the cold water inlet valve to 5.
the water heater to free the tank of sediments. Close
when draining water is clear.
Disconnect the garden hose and remove the drain 6.
valve from the water heater.
Refer to Plumbing Installation and Hot Water Generator 7.
Startup.
14
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Plumbing Installation
Inspect the dip tube in the water heater cold inlet 1.
for a check valve. If a check valve is present it must
be removed or damage to the hot water generator
circulator will occur.
Remove drain valve and fitting.2.
Thread the 3/4-inch NPT x 3-1/2-inch brass nipple into 3.
the water heater drain port.
Attach the center port of the 3/4-inch FPT tee to the 4.
opposite end of the brass nipple.
Attach the 1/2-inch copper to 3/4-inch NPT adaptor to 5.
the side of the tee closest to the unit.
Install the drain valve on the tee opposite the adaptor.6.
Run interconnecting tubing from the tee to DHW water 7.
out.
Cut the cold water “IN” line going to the water heater.8.
Insert the reducing solder tee in line with cold water 9.
“IN” line as shown.
Run interconnecting copper tubing between the unit 10.
DHW water “IN” and the tee (1/2-inch nominal). The
recommended maximum distance is 50 feet.
To prevent air entrapment in the system, install a vent 11.
coupling at the highest point of the interconnecting
lines.
Insulate all exposed surfaces of both connecting water 12.
lines with 3/8-inch wall closed cell insulation.
NOTE: All plumbing and piping connections must comply
with local plumbing codes.
CAUTION: Never operate the DHW circulating
pump while dry. If the unit is placed in operation
before the hot water generator piping is
connected, be sure that the pump switch is set
to the OFF position.
Hot Water Generator Connections cont.
Hot Water Generator Startup
Close the drain valve to the water heater.1.
Open the cold water supply to the tank.2.
Open a hot water faucet in the building to bleed air 3.
from the system. Close when full.
Open the pressure relief valve to bleed any remaining 4.
air from the tank, then close.
If so equipped, unscrew the indicator plug 1 turn on 5.
the motor end of the pump until all air is purged from
the pump, then tighten the plug. Use vent couplings to
bleed air from the lines.
Carefully inspect all plumbing for water leaks and 6.
correct as required.
Before restoring electrical supply to the water heater, 7.
adjust the temperature setting on the tank.
On tanks with both upper and lower elements,
the lower element should be turned down to
the lowest setting, approximately 100°F. The
upper element should be adjusted to 120°F to
130°F. Depending upon the specific needs of
the customer, you may want to adjust the upper
element differently.
On tanks with a single element, lower the
thermostat setting to 120°F.
After the thermostat(s) is adjusted, replace the access 8.
cover and restore electrical supply to the water heater.
Make sure that any valves in the hot water generator 9.
water circulating circuit are open.
Turn on the unit to first stage heating. 10.
The DHW pump should be running. When the pump 11.
is first started, open the inspection port 1 turn (if
equipped) until water dribbles out, then replace. Allow
the pump to run for at least five minutes to ensure that
water has filled the circulator properly. Be sure the
switch for the DHW pump (SW4) is “ON”. The DHW
“OFF” LED on the unit should not be illuminated.
The temperature difference between the water 12.
entering and leaving the hot water generator should be
5°F to 15°F. The water flow should be approximately
0.4 GPM per ton of nominal cooling.
Allow the unit to heat water for 15 to 20 minutes to be 13.
sure operation is normal.
15
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Electrical Data
Model Rated
Voltage
Voltage
Min/Max
Compressor HWA
Pump
FLA
Ext
Loop
FLA
Total
Unit
FLA
Min
Circ
Amp
Max
Fuse/
HACR
MCC RLA LRA LRA*
022 208-230/60/1 197/253 14.0 9.0 48.0 17.0 0.4 5.4 14.8 17.1 25
030 208-230/60/1 197/253 20.0 12.8 58.3 21.0 0.4 5.4 18.6 21.8 30
036 208-230/60/1 197/253 22.0 14.1 73.0 26.0 0.4 5.4 19.9 23.4 35
042 208-230/60/1 197/253 26.0 16.6 79.0 28.0 0.4 5.4 22.4 26.6 40
048 208-230/60/1 197/253 31.0 19.8 109.0 38.0 0.4 5.4 25.6 30.6 50
060 208-230/60/1 197/253 41.2 26.4 134.0 47.0 0.4 5.4 32.2 38.8 60
070 208-230/60/1 197/253 47.0 30.1 158.0 55.0 0.4 5.4 35.9 43.4 70
026 208-230/60/1 197/253 16.0 10.2 52.0 18.0 0.4 5.4 16.0 18.6 25
038 208-230/60/1 197/253 26.0 16.6 82.0 29.0 0.4 5.4 22.4 26.6 40
049 208-230/60/1 197/253 33.0 21.1 96.0 34.0 0.4 5.4 26.9 32.2 50
064 208-230/60/1 197/253 40.0 25.6 118.0 41.0 0.4 5.4 31.4 37.8 60
072 208-230/60/1 197/253 42.5 27.2 150.0 53.0 0.4 5.4 33.0 39.8 60
5/6/09
Rated voltage of 208-230/60/1
HACR circuit breaker in USA only
Min/Max Voltage of 197/253
All fuses Class RK-5
* With optional IntelliStart
Thermostat Wiring
Single and Dual Capacity Wiring Diagram
Field low voltage point to point wiring:
From
Thermostat
To Air Handler
To Compressor
Section
C C C
R R R
G G
O O O
Y1 Y1 Y1
Y2 Y2 Y2
W2 W
L L
Air Handler transformer must be 75VA. 5/29/08
Be sure the available power is the same voltage and phase
as that shown on the unit serial plate. Line and low voltage
wiring must be done in accordance with local codes or the
National Electric Code, whichever is applicable. See unit
electrical data for fuse or circuit breaker sizing information.
16
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Wiring Schematics
Dual Capacity Split Wiring Schematic - 208-230/60/1
HWL
HP
LP
FD
97P774-31 12 /8/08
Status LED PCB
SW4
R
R
R
R
R
G
Y
R
T
T
240V L2 240V L1
240V L2
P6
Premier 2
Microprocessor
Logic Control
(DC Voltage)
P1
Fused L2
R
C
CC-GND
NO
CR2 COM
F1-10A 240V
Fused L2
NO
CR1 COM
1
2
3
4
5
6
7
8
1
2
3
P4
Pink
Black
Blue
Orange
Orange
Pink
Yellow
Yellow
1
2
3C
P2
Down
C
1
2
3
4
5
6
7
Shut
SL1 In
Not
SL1 Out
Used
NOTE 1
Acc Com
Acc NC
Acc NO
1
2
3
P3
1 2 3 Main Logic PCB
F1-10A
240V
Tan
6
5
4
8
7
P5
12
1
2
9
10
3
4
9
11
2
10
8
1
12
5
3
13
14
15
16
11
G
W
O
R
C
Y1
Y2
LO
On
SW1
1
2
3
4
5
6
7
8
9
10
11
12
ECM2
Air Flow
Settings
Black
Blue
14
13
6
7
CC
NO NC
CR4 COM
NO NC
CR3 COM
RV
CCHI
Not Used
Not Used
On
SW3
OnSW2
1
2
3
4
5
6
7
8
No Htg3 / Htg3
Dehum / Norm
Fan / Comp
Loop / Well
Test / Norm
Outputs / Norm
Inputs / Norm
2 Speed / 1 Speed
Normal / Finish on 2nd (Note 2)
No RPM / RPM
Electric Heat / Normal
Envision / E Series or Premier
1
2
3
4
5
Pulse L / Constant L (NOTE 4)
Field Selection Dips - #1 On, #6 On, #7 On
Drain pan overflow Lockout
FD thermistor (loop<15°F,well<30°F) Lockout
High Pressure
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm Lockout
Microprocessor malfunction*
HWL thermistor > 130°F
DHW pump switch off
Drain
Water Flow
High Press
Low Press / CA
Air Flow
Status
DHW Limit
DHW off
LED Normal Display Mode
#1 Off, #6 On, #7 On
Drain pan overflow
FD thermistor (loop<15°F, well<30°F)
High Pressure
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm
Not Used
HWL thermistor > 130°F
DHW pump switch off
Current Fault Status
#6 Off, #7 On
Y1
Y2
O
G
W
SL1
SL2
--
Inputs
#6 On, #7 Off
Compressor Lo
Compressor Hi
RV
FAN
DHW Pump
Loop Pump 1
Loop Pump 2
--
Outputs
#6 Off, #7 Off
Blower Lo
Blower Med
Blower Hi
Aux Heat #1
Aux Heat #2
AuxHeat #3
Aux Heat #4
--
Outputs 2
Diagnostic Modes
*Green LED not flashing
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
Switch -Hot Water On/Off
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
CR1 -
CR 2 -
CR3 -
CR4 -
F1 and F 2 -
FD -
HE -
HP -
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Freeze Detection Sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 12 position
DIP package 8 position
DIP package 5 position
Hot water pump enable switch
Thermal limit switch
Legend
Relay Contacts -
N.O., N.C.
G
T
132
P
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER 1 to ER4 - Aux heat stage relays
HWL - Hot water limit sensor
SC - Start Contactor
Start RelaySR -
CS - Compressor Solenoid **DC Coil**
CA - Comfort Alert
Y1
Y2
O
R
C
L
C
R
Fossil Fuel
Furnace
Thermostat
24 VAC
Common Common
24 VA C
Fault Signal
Reversing Valve
2 nd Stage Compressor
1st Stage Compressor Y1
Y2
O
R
C
LO
EZ Split
GG Fan
W
W
Auxiliary Heat Relay
Duel Fuel Wiring Diagram
Using Field Installed Relay
Note : Field installed DPST dual fuel relay
( Required for dual fuel installation )
Auxiliary Heat Relay
P2
P1
Sh u t
Auxiliary
Heat Relay
Down
= chassis
LED Flash Code Description
Green Solid Module Has Power
Red Solid Y1 Present But Compressor Not Running
Code 1 Long Run Time
Code 2 System Pressure Trip
Code 3 Short Cycling
Code 4 Locked Rotor
Code 5 Open Circuit
Code 6 Open Start Circuit
Code 7 Open Run Circuit
Code 8 Welded Contactor
Code 9 Low Voltage
Yellow
Comfort Alert Status
NOT USED
NOTE 5
DHW
Pump
Blu
3A
Fuse Pink
Blu(17)
Ext Pump
1/2 hp Total
208-230/60/1
Pump Pump
G
2
1
PB1
1
2
Yel(8)
Pink(13)
Unit Power
208-230/60/1
GL2 L1
CC
C
S
R
Run
Capacitor
Red BlackBlue
Tan
(16)
Comfort Alert
CC
Blk(1 )
Violet(2)
Comfort
Alert
R
Y
C
Violet(3)
Blk(5)
Yel(6)
LComfort Alert
NOTE 3
CS
+
-
DC SOL
Wht(4)
Brn(15)Org(14)
Gry( 9)
C
NOTE 6
SL1 In
SL1 Out
Optional
Remote Unit
Without
Loop Pump
Y2
Notes:
1 - 24V Accessory relay (see SW2-3 for description of operation)
2 - This Switch allows the unit to down stage with the t-stat when OFF and finish on
second stage when ON. Finish second stage reduces stage changing in recip
dual capacity compressors and should be ON for unzoned Dual Cap E-Series or
Premier 2 speed units.
3 - Comfort Alert fault output to Premier Control Board
4 - SW2-8 must be in the OFF position for pulsed “L” lockout signal and in the ON
position for constant “L” lockout signal.
5 - DHW pump only in models with hot water generation option.
6 - Connection of remote unit that does not have a loop pump for slave operation.
17
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Wiring Schematics cont.
Single Speed Split Wiring Schematic - 208-230/60/1
HWL
HP
LP
FD
97P774-30 12/8/08
Status LED PCB
SW4
R
R
R
R
R
G
Y
R
T
T
240V L2 240V L1
240V L2
P6
Premier 2
Microprocessor
Logic Control
(DC Voltage)
P1
Fused L2
R
C
CC-GND
NO
CR2 COM
F1-10A 240V
Fused L2
NO
CR1 COM
1
2
3
4
5
6
7
8
1
2
3
P4
Pink
Black
Blue
Orange
Orange
Pink
Yellow
Yellow
1
2
3C
P2
Down
C
1
2
3
4
5
6
7
Shut
SL1 In
Not
SL1 Out
Used
NOTE 1
Acc Com
Acc NC
Acc NO
1
2
3
P3
1 2 3 Main Logic PCB
F1-10A
240V
Tan
6
5
4
8
7
P5
12
1
2
9
10
3
4
9
11
2
10
8
1
12
5
3
13
14
15
16
11
G
W
O
R
C
Y1
Y2
LO
On
SW1
1
2
3
4
5
6
7
8
9
10
11
12
ECM2
Air Flow
Settings
Black
Blue
14
13
6
7
CC
NO NC
CR4 COM
NO NC
CR3 COM
RV
CCHI
Not Used
Not Used
On
SW3
OnSW2
1
2
3
4
5
6
7
8
No Htg3 / Htg3
Dehum / Norm
Fan / Comp
Loop / Well
Test / Norm
Outputs / Norm
Inputs / Norm
2 Speed / 1 Speed
Normal / Finish on 2nd (Note 2)
No RPM / RPM
Electric Heat / Normal
Envision / E Series or Premier
1
2
3
4
5
Pulse L / Constant L (NOTE 4)
Field Selection Dips - #1 On, #6 On , #7 On
Drain pan overflow Lockout
FD thermistor (loop<15°F, well<30°F) Lockout
High Pressure
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm Lockout
Microprocessor malfunction*
HWL thermistor > 130°F
DHW pump switch off
Drain
Water Flow
High Press
Low Press / CA
Air Flow
Status
DHW Limit
DHW off
LED Normal Display Mode
#1 Off, #6 On, #7 On
Drain pan overflow
FD thermistor (loop<15°F, well<30°F)
High Pressure
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm
Not Used
HWL thermistor > 130°F
DHW pump switch off
Current Fault Status
#6 Off, #7 On
Y1
Y2
O
G
W
SL1
SL2
--
Inputs
#6 On, #7 Off
Compressor Lo
Compressor Hi
RV
FAN
DHW Pump
Loop Pump 1
Loop Pump 2
--
Outputs
#6 Off, #7 Off
Blower Lo
Blower Med
Blower Hi
Aux Heat #1
Aux Heat #2
AuxHeat #3
Aux Heat #4
--
Outputs2
Diagnostic Modes
*Green LED not flashing
Notes:
1 - 24V Accessory relay (see SW2-3 for description of operation)
2 - This Switch allows the unit to down stage with the t-stat when OFF and finish on
second stage when ON. Finish second stage reduces stage changing in recip
dual capacity compressors and should be ON for unzoned Dual Cap E-Series or
Premier 2 speed units.
3 - Comfort Alert fault output to Premier Control Board
4 - SW2-8 must be in the OFF position for pulsed “L” lockout signal and in the ON
position for constant “L” lockout signal.
5 - DHW pump only in models with hot water generation option.
6 - Connection of remote unit that does not have a loop pump for slave operation.
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
Switch -Hot Water On/Off
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
CR1 -
CR 2-
CR3 -
CR4 -
F1 and F2 -
FD -
HE -
HP -
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Freeze Detection Sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 12 position
DIP package 8 position
DIP package 5 position
Hot water pump enable switch
Thermal limit switch
Legend
Relay Contacts -
N.O., N.C.
G
T
132
P
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER 1 to ER4 - Aux heat stage relays
HWL - Hot water limit sensor
SC - Start Contactor
Start RelaySR -
CS - Compressor Solenoid **DC Coil**
CA - Comfort Alert
Y1
Y2
O
R
C
L
C
R
Fossil Fuel
Furnace
Thermostat
24 VAC
Common Common
24 VAC
Fault Signal
Reversing Valve
2 nd Stage Compressor
1st Stage Compressor Y1
Y2
O
R
C
LO
EZ Sp lit
GG Fan
W
W
Auxiliary Heat Relay
Duel Fuel Wiring Diagram
Using Field Installed Relay
Note : Field installed DPST dual fuel relay
( Required for dual fuel installation )
Auxiliary Heat Relay
P2
P1
Shut
Auxiliary
Heat Relay
Down
= chassis
LED Flash Code Description
Green Solid Module Has Power
Red Solid Y1 Present But Compressor Not Running
Code 1 Long Run Time
Code 2 System Pressure Trip
Code 3 Short Cycling
Code 4 Locked Rotor
Code 5 Open Circuit
Code 6 Open Start Circuit
Code 7 Open Run Circuit
Code 8 Welded Contactor
Code 9 Low Voltage
Yellow
Comfort Alert Status
NOT USED
NOTE 5
DHW
Pump
Blu
3A
Fuse Pink
Blu(17)
Ext Pump
1/2 hp Total
208-230/60/1
Pump Pump
G
2
1
PB1
1
2
Yel(8)
Pink(13)
Unit Power
208-230/60/1
GL2 L1
CC
C
S
R
Run
Capacitor
Red BlackBlue
Tan
(16)
Comfort Alert
CC
Blk(1 )
Violet(2)
Comfort
Alert
R
Y
C
Violet(3)
Blk(5)
Yel(6)
L Comfort Alert
NOTE 3
Brn(15)Org(14)
Gry( 9)
C
NOTE 6
SL1 In
SL1 Out
Optional
Remote Unit
Without
Loop Pump
18
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Startup
The unit will not operate until all the inputs and safety
controls are checked for normal conditions. At first power-
up, a four-minute delay is employed before the compressor
is energized.
Component Sequencing Delays
Components are sequenced and delayed for optimum
space conditioning performance.
Accessory Relay
An accessory relay on the control board allows for field
connection of solenoid valves, electronic air cleaners, etc.
The accessory relay has a normally open output and a
normally closed output.
Short Cycle Protection
The control employs a minimum "off" time of four minutes
to provide for short cycle protection of the compressor.
Shutdown Mode
A 24VAC common signal to the “shutdown” input on
the control board puts the unit into shutdown mode.
Compressor, hot water pump and blower operation are
suspended.
Safety Controls
The Envision control receives separate signals for a high
pressure switch for safety, a low pressure switch to prevent
loss of charge damage, and a low suction temperature
thermistor for freeze detection. Upon a continuous
30-second measurement of the fault (immediate for
high pressure), compressor operation is suspended, the
appropriate lockout LED begins flashing. (Refer to the
"Fault Retry" section below.)
Testing
The Envision control allows service personnel to shorten
most timing delays for faster diagnostics. (Refer to the
Field Selection DIP switch SW2-1.)
Fault Retry
All faults are retried twice before finally locking the unit
out. An output signal is made available for a fault LED at
the thermostat. The “fault retry” feature is designed to
prevent nuisance service calls.
Diagnostics
The Envision control board allows all inputs and outputs to
be displayed on the LEDs for fast and simple control board
diagnosis. (Refer to the Field Selection DIP Switch SW2-1.)
Hot Water High Limit
(Domestic Hot Water Option)
This mode occurs when the hot water input temperature
is at or above 130°F for 30 continuous seconds. The DHW
limit status LED on the unit illuminates and the hot water
pump de-energizes. Hot water pump operations resume on
the next compressor cycle or after 15 minutes of continuous
compressor operation during the current thermostat
demand cycle.
Hot Water Justification
Since compressor hot gas temperature is dependant on
loop temperature in cooling mode, loop temperatures may
be too low to allow proper heating of water. The control will
monitor water and refrigerant temperatures to determine if
conditions are satisfactory for heating water. The DHW limit
status LED on the unit illuminates when conditions are not
favorable for heating water.
Heating Operation
Heat, 1st Stage (Y1)
The blower motor is started immediately, the loop pump
is energized 5 seconds after the “Y1” input is received, and
the compressor is energized on low capacity 10 seconds
after the “Y1” input. The hot water pump is cycled 30
seconds after the “Y1” input.
Heat, 2nd Stage (Y1,Y2) Single-Speed Units
The hot water pump is de-energized, which directs all heat
to satisfying the thermostat, and the blower changes to
high speed 15 seconds after the “Y2” input (ECM only).
Heat, 2nd Stage (Y1,Y2) Dual Capacity Units
The second stage compressor will be activated 5 seconds
after receiving a “Y2” input as long as the minimum first
stage compressor run time of 1 minute has expired. The
ECM blower changes from medium to high speed 15
seconds after the “Y2” input.
The Comfort Alert will delay the second stage compressor
until 5 seconds after it receives a “Y2” from the board.
Microprocessor Control
19
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Microprocessor Control cont.
Heat, 3rd Stage (Y1,Y2,W) Single-Speed Units
The first stage of resistance heat is energized 10 seconds
after “W” input, and with continuous 3rd stage demand,
the additional stages of resistance heat engage 90 seconds
after the first stage.
Heat, 3rd Stage (Y1,Y2,W) Dual Capacity Units
The hot water pump is de-energized which directs all heat
to satisfy the thermostat. The 1st stage of resistance heat is
energized 10 seconds after “W” input, and with continuous
3rd stage demand, the additional stages of resistance heat
engage 90 seconds after the first stage.
Emergency Heat (W only)
The blower is started on high speed, and the first stage of
resistance heat is energized 10 seconds after the "W" input.
Continuing demand will engage the additional stages of
resistance heat 90 seconds after the first stage.
Cooling Operation
In all cooling operations, the reversing valve directly
tracks the “O” input. Thus, anytime the “O” input is present,
the reversing valve will be energized.
Cool, 1st Stage (Y1,O)
The blower motor and hot water pump are started
immediately, the loop pump(s) is energized 5 seconds after
the “Y1” input is received. The compressor will be energized
(on low capacity for Dual Capacity units) 10 seconds after
the “Y1” input. The ECM blower will operate at 85% of
medium speed if in dehumidification mode.
Cool, 2nd Stage (Y1, Y2, O) Single Speed Units
The blower changes to high speed (85% of high speed if
in dehumidification mode) 15 seconds after the “Y2” input
(ECM only).
Cool, 2nd Stage (Y1, Y2, O) Dual Capacity Units
The second stage compressor will be activated 5 seconds
after receiving a “Y2” input as long as the minimum first
stage compressor run time of 1 minute has expired. The
ECM blower changes to high speed 15 seconds after the
“Y2” input (85% of high speed if in dehumidification mode).
The Comfort Alert will delay the second stage compressor
until 5 seconds after it receives a “Y2” from the board.
Blower (G only)
The blower starts and operates on low speed.
Lockout Conditions
During lockout mode, the appropriate unit and thermostat
lockout LEDs will illuminate. The compressor, loop pump,
hot water pump, and accessory outputs are de-energized.
The blower will continue to run on low speed. If the
thermostat calls for heating, emergency heat operation will
occur.
Comfort Alert lockouts cannot be reset at the thermostat.
All other lockout modes can be reset at the thermostat
after turning the unit off, then on, which restores normal
operation but keeps the unit lockout LED illuminated.
Interruption of power to the unit will reset a lockout
without a waiting period and clear all lockout LEDs.
High Pressure
This lockout mode occurs when the normally closed safety
switch is opened momentarily (set at 600 PSI).
Low Pressure
This lockout mode occurs when the normally closed low
pressure switch is opened for 30 continuous seconds (set
at 40 PSI). A low pressure fault may also be indicated when
a Comfort Alert lockout has occurred.
Freeze Detection (Water Flow)
This lockout mode occurs when the freeze detection
thermistor temperature is at or below the selected point
(well 30°F or loop 15°F) for 30 continuous seconds.
IntelliStart
Some models shall be equipped with an optional
IntelliStart. IntelliStart is a single phase soft starter which
reduces the normal start current (LRA) by 60-70%. This
allows the heat pump to more easily go “off grid.” Using
IntelliStart will also provide a substantial reduction in light
flicker, reduce start-up noise, and improve the compressor’s
start behavior. The IntelliStart is self-calibrating and may
take several starts to optimize the compressor’s starting
characteristics.
Features:
Automatic adjustment of the compressor starting
current to the available supply voltage —maintaining
constant starting torque and current.
Supply line impedance monitoring and compensation.
Automatic compensation for residual backpressure in
the system.
Monitoring of supply voltage while compressor is
running to prevent motor stalling, causing excessive
currents, under low voltage conditions.
Light flicker reductions of up to 10:1 over LRA under
the same conditions.
20
NSZ/NDZ INDOOR SPLIT INSTALLATION MANUAL
Green "POWER" LED - module has power
Red "TRIP" LED - Thermostat "Y" demand signal is present, but the compressor is not running.
Yellow "ALERT" LED LED Description Cause
Flash Code 1 Long Run Time Not applicable
Flash Code 2 System Pressure Trip Not applicable
Flash Code 3 Short Cycling Compressor run time of less than 3 minutes on 4 consecutive cycles
Flash Code 4 Locked Rotor Four consecutive compressor protector trips indicating compressor won't start
Flash Code 5 Open Circuit "Y" thermostat demand signal with no compressor current
Flash Code 6 Open Start Circuit "Y" thermostat demand signal with no current in the start circuit
Flash Code 7 Open Run Circuit "Y" thermostat demand signal with no current in the run circuit
Flash Code 8 Welded Contactor Current detected with no "Y" thermostat demand signal present
Flash Code 9 Low Voltage Less than 17 VAC detected in control circuit
* Flash code number corresponds to a number of LED flashes, followed by a pause and then repeated.
* TRIP and ALERT LEDs flashing at the same time indicates control circuit voltage is too low for operation.
* Reset ALERT flash code by removing 24 VAC power from module.
* Last ALERT flash code is displayed for 1 minute after module is powered on.
Resetting Comfort Alert Codes
Alert codes can be reset manually by cycling power off and on to the Comfort Alert module. Alert codes will reset automatically if
conditions return to normal.
Flash Code Number LED Description Automatic Reset of Alert Codes
Flash Code 1 Long Run Time Not applicable
Flash Code 2 System Pressure Trip Not applicable
Flash Code 3 Short Cycling Four "alert free" on and off cycles to reset automatically
Flash Code 4 Locked Rotor Four "alert free" on and off cycles to reset automatically
Flash Code 5 Open Circuit One "alert free" on and off cycles to reset automatically
Flash Code 6 Open Start Circuit One "alert free" on and off cycles to reset automatically
Flash Code 7 Open Run Circuit One "alert free" on and off cycles to reset automatically
Flash Code 8 Welded Contactor One "alert free" on and off cycles to reset automatically
Flash Code 9 Low Voltage Resets when voltage rises above 19 VAC
* Reset ALERT flash code by removing 24 VAC power from module.
Comfort Alert Flash Codes
Microprocessor Control cont.
Compressor Monitoring/Comfort Alert
The Comfort Alert displays abnormal compressor condi-
tions through a unique flash code and communicates the
conditions to the heat pump microprocessor control. The
heat pump microprocessor will determine which fault to act
on and ignore. Fault codes 2 (system pressure), 4 (locked
rotor), 6 (open start circuit), and 7 (open run circuit) will re-
sult in a lockout. All other fault codes are passive. All com-
pressor alerts are displayed on the module by flashing the
yellow Alert LED a specific number of times consecutively
followed by a pause, and then repeated. The number of
consecutive flashes or “Flash Code” correlates to a specific
abnormal condition. The red “TRIP” LED means there is a
thermostat demand signal “Y” present but the compressor
is not running. The green “POWER” LED means the module
has power.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

WaterFurnace NSZ Installation guide

Category
Heat pumps
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI