Kichler Lighting 45650CLP User manual

Type
User manual
IS-45648-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Aach mounng strap[A] to outlet box[D] using the
strap mounng screws[E]. Mounng strap can be
adjusted to suit posion of xture.
2) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Mounting
Strap
[B] Fixture
[C] Mounting
Screws
[D] Outlet Box
[E] Strap
Mounting
Screws
[F] Thumb Screw
[G] Glass
Cylinder
[H] Tube Cap
[I] Square End
Piece
3) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
4) Push xture to wall in a horizontal posion. Make sure all
wires are inside canopy and do not get pinched between
canopy and wall.
5) Place the four (4) mounng screws[C] into the sides of
the xture and ghten to secure xture to wall.
6) Remove the thumb screw[F] from the end of the xture
and slide out the square end piece[I] and remove the
tube cap[H].
7) Insert recommended bulbs. (Not supplied).
8) Carefully slide the glass cylinder[G] over the end of the
xture unl seated against the tube cap.
9) Place the tube cap[H] onto the end of the installed
glass cylinder and slide in the square end piece[I] into
the open end of xture[B] up to the installed tube cap.
Secure into place with the thumb screw[F]. (DO NOT
over ghten).
Installaon Instrucons (connued)
D
E
A
C
B
G
H
F
I
IS-45648-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Aach mounng strap[A] to outlet box[D] using the
strap mounng screws[E]. Mounng strap can be
adjusted to suit posion of xture.
2) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Mounting
Strap
[B] Fixture
[C] Mounting
Screws
[D] Outlet Box
[E] Strap
Mounting
Screws
[F] Thumb Screw
[G] Glass
Cylinder
[H] Tube Cap
[I] Square End
Piece
3) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
4) Push xture to wall in a horizontal posion. Make sure all
wires are inside canopy and do not get pinched between
canopy and wall.
5) Place the four (4) mounng screws[C] into the sides of
the xture and ghten to secure xture to wall.
6) Remove the thumb screw[F] from the end of the xture
and slide out the square end piece[I] and remove the
tube cap[H].
7) Insert recommended bulbs. (Not supplied).
8) Carefully slide the glass cylinder[G] over the end of the
xture unl seated against the tube cap.
9) Place the tube cap[H] onto the end of the installed
glass cylinder and slide in the square end piece[I] into
the open end of xture[B] up to the installed tube cap.
Secure into place with the thumb screw[F]. (DO NOT
over ghten).
Installaon Instrucons (connued)
D
E
A
C
B
G
H
F
I
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler Lighting 45650CLP User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI