RULES FOR STORAGE OF USED ELECTRICAL EQUIPMENT
The used electrical equipment may not be stored together with other waste. Store it at
sites intended for this purpose. For this reason, address the responsible institutions or
companies dealing with waste recycling.
- Directive 2002/96/EC/ dated January 27th, 2003
MOUNTING
The panel must be mounted on the wall of the building, in a place where the impact of
unfavourable atmospheric conditions is minimal. We recommend the installation of the
panel at a height of about 1.35m.
The flush mounting box is mounted by means of expansion bolts and plaster in the right
hole in the wall. The front edge of the mounting box should be even with the wall surface.
ATTENTION! For the purpose of proper functioning as well as ensuring safety of use, the
panel (in a metal frame) must be connected at the installation site to the earthing,
connecting the earth terminal on the body with the appropriate protective installation (PE).
It is recommended to provide the connection between the panel and the electrical door
strike and the power supply convertor with the use of a wire with a cross section of 1 mm²
( e.g. LY1,0). The length of the wire should not exceed 7m in the case of an electrical
door strike circuit and 15m in the case of the power supply circuit!
In the case of smaller sections and too long connections, there may occur voltage drops
during opening of the electrical door lock, causing interferences in the operation of the
panel even after the opening operation is finished.
15V DC voltage from the video power supply (DR-45-15 recommended) to adder
terminals should be provided with a 3x1mm² cable.
In case of supplying the power from a buffer power supply with battery, the voltage 13,8V
should be connected to the adder's terminals.
The electrical door strike without specific polarisation is to be connected at will to
“ELOCK” terminals.
All the connections of the installation must be soldered!
The following wires are led to the panel:
• 3 power supply cores x 1mm²
• 2 cores x 1mm²– to the electrical door strike,
• 1 core of a wire in yellow-green insulation – to connect the enclosure earthing. UTP
network cable (standard T568A or T568B) - busbar
INSTALLATION AND CONNECTION OF THE UNIPHONES
The uniphones have to be installed in accordance with the installation manual of the
manufacturer. The connections shall be made paying particular attention to the number
setting in the uniphone decoder and proper (polarisation) connection to the “LINE”
terminals of the panel.
ADJUSTMENT OF THE SOUND LEVEL
The sound levels of the panel are set by the manufacturer, but for individual needs, they
may be adjusted. The volume level settings shall be made after obtaining the connection
with the uniphone in the following way:
-using the ”MIC” potentiometer, adjust the sound volume level in the uniphone handsets
from the panel's microphone (from the bottom),
- using the ”SPK” potentiometer, adjust the sound volume level in the loudspeaker of
the panel, coming from the uniphones in the premises (from above),
After setting these values, establish the position of points in which the excitation (beeping)
in the loudspeaker takes place by turning the ”BALANCE” with the potentiometer, and set
the potentiometer halfway between these points.
ELECTRICAL PARAMETER
• Power supply15V DC – (e.g., power supply DR-45-15)