NXP Air cooled

Vacon NXP Air cooled, NXP IP00 Modules Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Vacon NXP Air cooled Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the recommended supporting bar cabinet width for an FR11 power module?
    What is the minimum bending radius for the optical fibers?
    What is the maximum allowed lifting angle for the power module?
    What is the recommended cooling air required for an FI10 power module?
    What is the minimum air hole size required on the switchgear for an FI12 power module?
vacon nxp
ac drives
ip00 modules
frames fr10 to fr14
installation quick guide
Document ID:
Rev. A
Manual authoring:
Vacon Plc.
Runsorintie 7
65380 Vaasa
Finland
Subject to change without prior notice
© 2012 Vacon Plc.
Find your nearest Vacon office
on the Internet at:
www.vacon.com
quick installation guide
ip00
IP00 Module Installation Quick Guide
FR10, FR11, FI9, FI10, FI12, FI13 (FR12, FI14)
Grounding and cabling the unit
1-1 Products included in the delivery
1-2 Lifting the power module
NOTE!
Place the lifting hooks symmetrically in at least two holes. The lifting
devices must be able to carry weight of the module
NOTE!
Maximum allowed lifting angle 45°
Frame
FR10
FR11
FI9
FI10
FI12
FI13
Weight kg
123
210
65
100
200
302
NOTE!
FR12=2 x FR10; FI14=2 x FI13 power modules
4
9
Power module
AC choke
Control unit
Max 45
°
3-3 Installing the motor cable
Cable fixing clamps
EMC grounding
360°
3-2 Installing the optical fibres
Min bending radius
50 mm
X2
X10
1
2
3
4
5
6
7
IP00 Module Installation Quick Guide
FR10, FR11, FI9, FI10, FI12, FI13 (FR12, FI14)
Delivered modules / Installing AC chokes and power module
5
8
1-3 Installing power module
Frame
FR10
FR11
FI9
FI10
FI12
FI13
Device width
A / mm
500
709
239
239
478
708
Supporting bar
range B / mm
A - 50mm
A - 20mm
A - 50mm
A - 50mm
A - 50mm
A - 50mm
Recommended
cabinet width
C / mm
600
800
400
400
600
800
NOTE!
For detailed drawing, see manual.
B
C
AC choke
A
3-1 Connecting the internal power cable
See IP00 Module Installation Manual for details.
FI FR
DC BUS
U V W
L1
L2
L3
U V W
L1
L2
L3
CHOKE CHOKE
IP00 Module Installation Quick Guide
FR10, FR11, FI9, FI10, FI12, FI13 (FR12, FI14)
Ventilation
6
7
2-2 Arranging ventilation of the enclosure
Ventilation requirements table
CAUTION!
It is of utmost importance for the operation and lifetime of the frequency
converter that the closure is well ventilated to keep the temperature below the
maximum operating temperature. Repeated overheating will shorten the
lifetime of the converter.
Frame
FR10
FR11
FI9
FI10
FI12
FI13
Cooling air
required m
3
/h
2800
4200
1150
1400
2800
4200
Minimum air hole
on switchgear / dm
2
1) inlet
13
19,5
5,5
6,5
13
19,5
2) outlet
7
10,5
3
4
7
10,5
1
2
2-1 Steering the internal air flow
NOTE:
Outgoing air must be directed out of the cabinet so that it does not mix with
incoming cooling air.
Air barrier
Duct
or
/