Vacon NXP Air cooled Installation guide

Type
Installation guide

This manual is also suitable for

Vacon NXP Air cooled is a versatile and powerful frequency converter that offers precise motor control and energy savings in various applications. With its compact design, robust construction, and advanced features, it's an ideal choice for demanding industrial environments. This device provides high-performance vector control, allowing for accurate torque and speed control of induction motors.

Vacon NXP Air cooled is a versatile and powerful frequency converter that offers precise motor control and energy savings in various applications. With its compact design, robust construction, and advanced features, it's an ideal choice for demanding industrial environments. This device provides high-performance vector control, allowing for accurate torque and speed control of induction motors.

vacon nxp
ac drives
ip00 modules
frames fr10 to fr14
installation quick guide
Document ID:
Rev. A
Manual authoring:
Vacon Plc.
Runsorintie 7
65380 Vaasa
Finland
Subject to change without prior notice
© 2012 Vacon Plc.
Find your nearest Vacon office
on the Internet at:
www.vacon.com
quick installation guide
ip00
IP00 Module Installation Quick Guide
FR10, FR11, FI9, FI10, FI12, FI13 (FR12, FI14)
Grounding and cabling the unit
1-1 Products included in the delivery
1-2 Lifting the power module
NOTE!
Place the lifting hooks symmetrically in at least two holes. The lifting
devices must be able to carry weight of the module
NOTE!
Maximum allowed lifting angle 45°
Frame
FR10
FR11
FI9
FI10
FI12
FI13
Weight kg
123
210
65
100
200
302
NOTE!
FR12=2 x FR10; FI14=2 x FI13 power modules
4
9
Power module
AC choke
Control unit
Max 45
°
3-3 Installing the motor cable
Cable fixing clamps
EMC grounding
360°
3-2 Installing the optical fibres
Min bending radius
50 mm
X2
X10
1
2
3
4
5
6
7
IP00 Module Installation Quick Guide
FR10, FR11, FI9, FI10, FI12, FI13 (FR12, FI14)
Delivered modules / Installing AC chokes and power module
5
8
1-3 Installing power module
Frame
FR10
FR11
FI9
FI10
FI12
FI13
Device width
A / mm
500
709
239
239
478
708
Supporting bar
range B / mm
A - 50mm
A - 20mm
A - 50mm
A - 50mm
A - 50mm
A - 50mm
Recommended
cabinet width
C / mm
600
800
400
400
600
800
NOTE!
For detailed drawing, see manual.
B
C
AC choke
A
3-1 Connecting the internal power cable
See IP00 Module Installation Manual for details.
FI FR
DC BUS
U V W
L1
L2
L3
U V W
L1
L2
L3
CHOKE CHOKE
IP00 Module Installation Quick Guide
FR10, FR11, FI9, FI10, FI12, FI13 (FR12, FI14)
Ventilation
6
7
2-2 Arranging ventilation of the enclosure
Ventilation requirements table
CAUTION!
It is of utmost importance for the operation and lifetime of the frequency
converter that the closure is well ventilated to keep the temperature below the
maximum operating temperature. Repeated overheating will shorten the
lifetime of the converter.
Frame
FR10
FR11
FI9
FI10
FI12
FI13
Cooling air
required m
3
/h
2800
4200
1150
1400
2800
4200
Minimum air hole
on switchgear / dm
2
1) inlet
13
19,5
5,5
6,5
13
19,5
2) outlet
7
10,5
3
4
7
10,5
1
2
2-1 Steering the internal air flow
NOTE:
Outgoing air must be directed out of the cabinet so that it does not mix with
incoming cooling air.
Air barrier
Duct
or
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Vacon NXP Air cooled Installation guide

Type
Installation guide
This manual is also suitable for

Vacon NXP Air cooled is a versatile and powerful frequency converter that offers precise motor control and energy savings in various applications. With its compact design, robust construction, and advanced features, it's an ideal choice for demanding industrial environments. This device provides high-performance vector control, allowing for accurate torque and speed control of induction motors.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI