1. I/O ADDRESS SELECTION
IR104 occupies 8 addresses in I/O memory, of which 6 are used. The address is selected with
jumpers JP1 and JP2. The pins listed under each jumper block are the pins that must be shorted with
a jumper for the In position. On each jumper block, pin 1 is on the left and pin 3 is on the right. Note
that on JP1, pins 1 and 2 are used, but pin 3 is never used. On JP2, pins 2 and 3 are used, but pin 1
is never used.
Address JP1 JP2
Hex Decimal pins 1 and 2 pins 2 and 3
240 576 Out Out
260 608 Out In
280 640 In Out
300 768 In In
2. I/O MAP
Base + Write Function Read Function
0 Relays 1-8 Read back value
1 Relays 9-16 Read back value
2 Relays 17-20 Read back value
3 -- --
4 -- Opto inputs 1-8
5 -- Opto inputs 9-16
6 -- Opto inputs 17-20
7 -- --
3. REGISTER BIT ASSIGNMENTS
Addr Operation D7 D6 D5 D4 D3 D2 D1 D0
0 Read/Write RLY8 RLY7 RLY6 RLY5 RLY4 RLY3 RLY2 RLY1
1 Read/Write RLY16 RLY15 RLY14 RLY13 RLY12 RLY11 RLY10 RLY9
2 Read/Write 0 0 0 0 RLY20 RLY19 RLY18 RLY17
3 X X X X X X X X
4 Read only IN8 IN7 IN6 IN5 IN4 IN3 IN2 IN1
5 Read only IN16 IN15 IN14 IN13 IN12 IN11 IN10 IN9
6 Read only 0 0 0 0 IN20 IN19 IN18 IN17
7 X X X X X X X X
Definitions:
Rly1 – Rly20 Relay outputs; 1 = on, 0 = 0ff
In1 – In20 Optoisolator inputs; 1 = off, 0 = on
X Bit not used
0 Bit reads back as a 0
IR104 programming information.doc Diamond Systems Corp. www.diamondsystems.com
4. I/O HEADER PINOUTS
Optocoupler inputs
Optocouplers are accessed through a 2x20 pin header CN3 at the top of the board. Pin 1 is on the left.
There is no difference between the A and B connection, since the inputs are not polarity sensitive.
In 1 A
1 2
In 1 B
In 2 A
3 4
In 2 B
In 3 A
5 6
In 3 B
In 4 A
7 8
In 4 B
In 5 A
9 10
In 5 B
In 6 A
11 12
In 6 B
In 7 A
13 14
In 7 B
In 8 A
15 16
In 8 B
In 9 A
17 18
In 9 B
In 10 A
19 20
In 10 B
In 11 A
21 22
In 11 B
In 12 A
23 24
In 12 B
In 13 A
25 26
In 13 B
In 14 A
27 28
In 14 B
In 15 A
29 30
In 15 B
In 16 A
31 32
In 16 B
In 17 A
33 34
In 17 B
In 18 A
35 36
In 18 B
In 19 A
37 38
In 19 B
In 20 A
39 40
In 20 B
Relay outputs
Realys are on 1x20 detachable screw terminal headers. CN1 on the left side of the board handles relays
1 – 10, while CN2 on the right side handles relays 11 – 20. The relay numbers are marked next to each
relay so you can identify each relay and its associated screw terminals. Pin 1 on CN2 is on the bottom,
i.e. CN2 pinout is reversed with respect to CN1. The drawings below indicate the pinouts according to
their actual board orientation. There is no difference between the A and B connection, since the relays
are not polarity sensitive. All connections are NO, normally open.
CN1 CN2
Relay 1 A
1 20
Relay 20 B
Relay 1 B
2 19
Relay 20 A
Relay 2 A
3 18
Relay 19 B
Relay 2 B
4 17
Relay 19 A
Relay 3 A
5 16
Relay 18 B
Relay 3 B
6 15
Relay 18 A
Relay 4 A
7 14
Relay 17 B
Relay 4 B
8 13
Relay 17 A
Relay 5 A
9 12
Relay 16 B
Relay 5 B
10 11
Relay 16 A
Relay 6 A
11 10
Relay 15 B
Relay 6 B
12 9
Relay 15 A
Relay 7 A
13 8
Relay 14 B
Relay 7 B
14 7
Relay 14 A
Relay 8 A
15 6
Relay 13 B
Relay 8 B
16 5
Relay 13 A
Relay 9 A
17 4
Relay 12 B
Relay 9 B
18 3
Relay 12 A
Relay 10 A
19 2
Relay 11 B
Relay 10 B
20 1
Relay 11 A
IR104 programming information.doc Diamond Systems Corp. www.diamondsystems.com
5. PROGRAMMING EXAMPLES
Example 1: Turn on a relay
Current state of relays 1 – 8 is relays 1-4 on, relays 5-8 off.
Turn relay 8 on:
Current data value at Base + 0 is 00001111 = 15
To turn on relay 8, we need to set bit 7 to 1.
Relay 8 = bit 7 = 10000000 = 128
New data value = 128 OR 15 = 143 (10001111)
Write 143 to Base + 0 to turn on relay 8 and keep relays 1-4 on, 5-7 off.
Example 2: Turn off a relay
Current state of relays 1 – 8 is relays 1-4 and 8 on, relays 5-7 off.
Turn relay 3 off:
Current data value at Base + 0 is 10001111 = 143
To turn off relay 3, we need to clear bit 2.
Relay 3 = bit 2 = 00000100 = 4
New data value = 143 AND NOT(4) = 139 (10001011)
Write 139 to Base + 0 to turn off relay 3 and keep relays 1, 2, 4, and 8 on, 5, 6, and 7 off.