  • Hello! I am an AI chatbot trained to assist you with the Kenmore 625.382080 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
OWNER'S MANUAL
Central Water
Whole Home
Filtration System
MODEL NO. 625.382080
Caution:
Read and follow all safety rules and operating
instructions before first use of this product.
Questions ?
Visit www.KenmoreWater.com
or call toll free 1-800-426-9345 (M - F, 7 AM - 6 PM CST)
Repair or Parts ? Call toll free 1-800-469-4663
See back cover for other Sears service numbers.
SAVE THIS MANUAL
Warranty
Installation
How It Works
Care Of
Specifications
Repair Parts
System tested and certified by NSF International
against NSF/ANSI Standard 42
for the reduction of chlorine taste and odor,
and certified to NSF/ANSI Standard 372.
Sears Brands Management Corporation, Hoffman
PRINTED IN U.S.A. www.KenmoreWater.com
Estates, IL 60179 U.S.A.
Part No. 7333705 (Rev. D 2/26/13)
WARRANTY ON THE KENMORE CENTRAL WATER
WHOLE HOME FILTRATION SYSTEM
ONE YEAR LIMITED WARRANTY ON CENTRAL WATER WHOLE HOME FILTRATION SYSTEM
When installed, operated and maintained according to all instructions supplied with the product, if this Central
Water Whole Home Filtration System fails due to a defect in material or workmanship within one year from
the date of purchase, call 1-800-4-MY-HOME ® to arrange for free repair.
TEN YEAR LIMITED WARRANTY AGAINST LEAKS
When installed, operated and maintained according to all instructions supplied with the product, if the Central
Water Whole Home Filtration System filter bed tank develops a leak within ten years from the date of pur-
chase, call 1-800-4-MY-HOME ® to arrange for free tank replacement. After the first year you must pay an ini-
tial trip charge.
All warranty coverage does not include the filter bed, which is an expendable item.
If this Central Water Whole Home Filtration System is ever used for other than private family purposes, all
warranty coverage applies for only 90 days from the date of purchase.
This warranty covers only defects in material and workmanship. Sears will NOT pay for:
1. A service technician to instruct the user in correct product installation, operation or maintenance.
2. A service technician to clean or maintain this product.
3. Damage to or failure of this product if it is not installed, operated or maintained according to the all
instructions supplied with the product.
4. Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intended
purpose.
5. Damage to or failure of this product caused by the use of detergents, cleaners, chemicals or utensils other
than those recommended in all instructions supplied with the product.
6. Damage to or failure of parts or systems resulting from unauthorized modifications made to this product.
Disclaimer of implied warranties; limitation of remedies
Customer's sole and exclusive remedy under this limited warranty shall be product repair as provided herein.
Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to
one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential dam-
ages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential dam-
ages, or limitation on the duration of implied warranties of merchantability or fitness, so these exclusions or
limitations may not apply to you.
This warranty applies only while this appliance is used in the United States or Canada.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to
state.
Sears Brands Management Corporation, Hoffman Estates, IL 60179
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
Unpack and Check Shipment ...................................................................... 4
Installation Requirements ........................................................................ 5-6
Installation .................................................................................. 7-11
How a Central Water Filtration System Works ........................................................ 11
Programming the Central Water System ............................................................ 12
Start Up Procedure ............................................................................. 13
Customizing Features / Options ................................................................. 14-16
Care of Your Central Water Filtration System ...................................................... 17-18
Troubleshooting .............................................................................. 19-21
Specifications & Performance Claims ............................................................... 22
Dimensions ................................................................................... 23
Wiring Schematic .............................................................................. 23
Exploded View & Parts List .................................................................... 24-27
Read all steps and guides carefully before installing
and using your Central Water Whole Home Filtration
System. Follow all steps exactly to correctly install.
Reading this manual will also help you to get all the
benefits from the Central Water Whole Home
Filtration System.
Do not attempt to use this product to make safe drink-
ing water from non-potable water sources. Do not use
the system on microbiologically unsafe water, or water
of unknown quality without adequate disinfection
before or after the system.
Use only lead-free solder and flux for all sweat-solder
connections, as required by federal codes.
Use care when handling the Central Water Whole
Home Filtration System. Do not turn upside down or
drop.
Avoid installing in direct sunlight. Excessive sun heat
may cause distortion or other damage to non-metallic
parts.
Check with your local public works department for
plumbing and sanitation codes. You must follow their
guides as you install the system. Follow your local
codes if they differ with guides in this manual. In
Massachusetts, plumbing code 248-CMR 3.00 and
10.00 shall be adhered to. Consult with a licensed
plumber.
The Central Water Whole Home Filtration System
works on water pressures of 30 psi (minimum) to 125
psi (maximum). If your house water pressure is over
the maximum, install a pressure reducing valve in the
water supply pipe to the Central Water Home
Filtration System.
The Central Water Whole Home Filtration System
works on 24 volt, 60 Hz electrical power only, supplied
by a direct plug-in transformer (included). Be sure to
use the included transformer and plug it into a nominal
120V, 60 cycle household outlet that is properly pro-
tected by an overcurrent device such as a circuit
breaker or fuse. If transformer is replaced, use only
the authorized service, Class II, 24V 1OVA transformer.
Do not install the Central Water Whole Home
Filtration System outside, or in extreme hot or cold
temperatures. Temperature of the water supply to the
Central Water Whole Home Filtration System must be
between 40°F and 120°F. Do not install on hot water.
This Central Water Whole Home Filter has a non-
metallic valve system. Installing it on metal plumbing
will break electrical continuity, which may interrupt
grounding for the home. You must restore electrical
continuity in your metal plumbing system (See Page 10).
European Directive 2002/96/EC requires all electrical and electronic
equipment to be disposed of according to Waste Electrical and Electronic
Equipment (WEEE) requirements. This directive or similar laws are in
place nationally and can vary from region to region. Please refer to your
state and local laws for proper disposal of this equipment.
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
3
INSPECT SHIPMENT
Your Central Water Whole Home Filtration System is
shipped complete in one carton. Remove all items from
your shipping carton.
Check all items against the packing list below. Note
any items lost or damaged in shipment. Note any dam-
age to the shipping carton. If problems exist, contact
the store where you purchased your Central Water
Whole Home Filtration System.
Keep the small parts in the parts bag until you are
ready to install them.
NOTE: Codes in the state of Massachusetts require
installation by a licensed plumber.
If you live in the state of Massachusetts, review plumb-
ing code 248-CMR of the Commonwealth of
Massachusetts before proceeding with the installation.
Bypass Valve O-rings
0
Drain Hose
Installation
Adaptors
Clips
Hose Clamps Adaptor Elbow
Figure 1
TOOLS NEEDED
Assemble the required tools before starting installation.
Read and follow instructions provided with any tools
listed here.
Screwdriver
Tape measure
Pliers
If using Soldered Copper Pipe
Tubing cutter
Lead-free solder and flux
Propane torch
Emery cloth, sandpaper or steel wool
Misc. copper pipe fittings
If using Threaded Pipe
Pipe cutter or hacksaw
Pipe joint compound
Threading tool
Misc. threaded pipe fittings
If using CPVC Plastic
Pipe cutter
Solvent cement
Hacksaw
Primer
Adjustable wrench
If using Other
Other pipe and fittings suitable for potable water as
required by piping system manufacturer and local
codes and/or ordinances.
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
4
LOCATION REQUIREMENTS
Consider the following when selecting an installation
location for the Central Water Whole Home Filtration
System.
Do not operate the Central Water Whole Home
Filtration System where freezing temperatures occur.
Do not attempt to treat water over 120°F. Freezing
temperatures or hot water damage voids the war-
ranty.
To condition all water in the home, install the Central
Water Whole Home Filtration System close to the
water supply inlet, and before all other plumbing
connections, except outside water pipes.
For a home with municipal water supply, install the
Central Water Whole Home Filtration System
between the home's incoming water supply and the
water softener, if one is being used (See Figure 2A).
If the home has well water, reverse the order of the
Central Water Filtration System and the water
softener (See Figure 2B).
A nearby drain is needed to carry away Clean Rinse
discharge water. Use a floor drain, laundry tub,
sump, standpipe, or other options (check your local
codes). See "Air Gap Requirements" and "Valve
Drain Requirements" sections. If a drain is not avail-
able, it is still passible to operate the Central Water
Whole Home Filtration System in a manual Clean
Rinse mode. See "Operating in Manual Clean Rinse
Mode." The automatic Clean Rinse must be disabled
if the Central Water Whole Home Filtration System
will not be connected to a drain (See Page 16).
The Central Water Whole Home Filtration System
works on 24 volt, 60 Hz electrical power only, sup-
plied by a direct plug-in transformer (included).
Provide an electrical outlet in accordance with NEC
and local codes.
Do not install the Central Water Whole Home
Filtration System on a hot water line (See Figures 2A
& 2B below).
THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
Untreated Water to
Cold Water
to House
Hot Water _,_
to House
Outside Faucets
t
Optional
J Sediment
Filter
City Water Supply
Water Water Central
Heater Softener Water
Filtration
System
Cold Water
to House
Hot Water _.,,_
to House
Untreated Water to
Outside Faucets
_Oplional
Filth--_ Sediment
!
Pressure
Tank
Figure 2A
Water Central Water -- I Well Water Supply
Heater Water Softener _L_
Filtration Well
System Pump I Figure 2B
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
5
PLUMBING CODES
All plumbing must be completed in accordance with
national, state and local plumbing codes.
In the state of Massachusetts: The Commonwealth
of Massachusetts plumbing code 248-CMR shall be
adhered to. A licensed plumber shall be used for
this installation.
AIR GAP REQUIREMENTS
A drain is needed for Clean Rinse discharge water. A
floor drain, close to the Central Water Filtration System,
is preferred. A laundry tub, standpipe, etc. are other
drain options. Secure valve drain hose in place. Leave
an air gap of 1-1/2" between the end of the hose and
the drain. This gap is needed to prevent backflow of
sewer water into the Central Water Whole Home
Filtration System. Do not put the end of the drain hose
into the drain.
VALVE DRAIN REQUIREMENTS
Using the flexible drain hose (included), measure and
cut to the length needed. Flexible drain hose is not
allowed in all localities (check your plumbing codes). If
local codes do not allow use of a flexible drain hose, a
rigid valve drain run must be used. Purchase a com-
pression fitting (1/4 NPT x 1/2 in. minimum tube) and
1/2" tubing from your local hardware store. Plumb a
rigid drain as needed (see Figure 3, below).
NOTE: Avoid drain hose runs longer than 30 feet. Make
the valve drain line as short and direct as possible.
It is recommended that the Central Water Whole
Home Filtration System be installed near a drain.
However, if a drain is not available, it is still possible to
operate the Central Water Whole Home Filtration
System in a manual Clean Rinse mode. See "Operating
in Manual Clean Rinse Mode" section. The automatic
Clean Rinse function must be disabled if the Central
Water Filtration System will not be connected to a drain.
CONNECTING VALVE TO DRAIN
_,.,,, Drain [
Fitting _
Clamp " -'__ ]_
Valve
Drain
Hose
Tie or wire
tubing in
place
Drain grate with 1"
dia. hole in center
Grounding wire must
connect metal pipes
To drain point other
than floor drain.
Support tubing in
place as needed.
Install adaptor
elbow using hose
clamp. Aim nozzle
down toward
center of drain
1-1/2"
air gap
FLOOR DRAIN
SUBSTITUTING RIGID DRAIN LINE
1/4 NPTThreads
Cti ....
Cut barbs from
drain fitting {pull
clip to remove fit-
ting from valve) Camp Fitting.
NPT x 1/2" O.D.
Tube (nat included)
1/2" Outside Dia.
Copper Tube (not
included)
air gap_
LAUNDRY TUB STANDPIPE
Figure 3
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
6
TURN OFF WATER SUPPLY
1. Close the main water supply valve, near the well
pump or water meter.
2. Open all faucets to drain water from the house
pipes.
NOTE: Be sure not to drain water from the water
heater, as damage to the water heater elements
could result.
MOVE THE CENTRAL WATER FILTRATION
SYSTEM INTO PLACE
1. Move the Central Water Whole Home Filtration
System into installation position. Set it on a level sur-
face. If needed, place the unit on a section of ply-
wood, a minimum of 5/8" thick. Then place shims
under the plywood to level the Central Water
Filtration System (see Figure 4).
Shim(s)
LEVEL IF NECESSARY
Plywood
/
Figure 4
CROSS OVER
In what direction does the water flow?
Be sure to plan piping so water flow is to the Central
Water Whole Home Filtration System valve INLET.
Plan a crossover if flow is from left to right.
Treated
Water from
Valve
OUTLET
t
Untreated
Water to
Valve
INLET
To Central Water
Filtration System
Figure 5
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
7
INLET- OUTLETPLUMBINGOPTIONS
Install a single bypass valve (provided) to the plumbing,
as shown in Fig. 8 OR if desired, a 3 valve bypass sys-
tem (parts not included) can be installed, as shown in
Figure 7. Bypass valves allow you to turn off water to
the Central Water Whole Home Filtration System for
maintenance if needed, but still supply water to the
house.
Use either:
Copper pipe
Threaded pipe
PEX (Crosslinked Polyethylene) pipe
CPVC plastic pipe
Other pipe approved for use with potable water
IMPORTANT: Do not solder with plumbing attached to
installation adapters and single valve
bypass. Soldering heat will damage the
adapters and valve.
NOTE: Before installing the bypass valve or copper
tube into the valve's INLET, remove the foam
piece that was placed in that port for shipping.
Before installing the bypass valve or copper tube into
the valve's OUTLET, make sure that the turbine and sup-
port are firmly in place, as shown in Figure 6.
Turbine Valve
.Support Outlet
Turbine
/
Figure 6
3 VALVE BYPASS
Central Water Filtration
SystemOUTLET
Central Water Filtration
SystemINLET
Figure 7
CONNECTING PLUMBING TO VALVE
OUT
Use Teflon@ tape,
pipe joint com-
pound or both
IN
1" NPT Sweat
Adapter (2)
_._ (not included)
8__ 1" NPT
_ Adapter (2)l
Clip (4))
\
Valve Bypass
Inlet Valve
Included
Use Teflon@ tape,
pipe joint com-
pound or both
Valve
Inlet
OUT IN
1" NPT Sweat
Adapter (2)
(not included)
1" NPT Clip (r_
Adapter (2)_ Included
Figure 8
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
ASSEMBLE INLET AND OUTLET PLUMBING
Measure, cut, and loosely assemble pipe and fittings
from the main water pipe to the inlet and outlet ports
of the Central Water Whole Home Filtration System
valve. Be sure to keep fittings fully together, and pipes
squared and straight.
Be sure the incoming water supply pipe goes to the
valve inlet side.
CONNECT INLET AND OUTLET PLUMBING
IMPORTANT:
Be sure to fit, align and support all plumbing to pre-
vent putting stress on the Central Water Whole
Home Filtration System valve inlet and outlet. Undue
stress from misaligned or unsupported plumbing may
cause damage and leaks at the valve.
Be sure to keep fittings fully together, and pipes
squared and straight.
Be sure incoming water supply pipe goes to the
Central Water Whole Home Filtration System valve
INLET side. Inlet and outlet are marked on the
valve. Trace the water flow direction to be sure.
Complete the inlet and outlet plumbing for the type of
pipe, as described below and at right.
Sears Flexible Connectors
Flexible connector hoses are available in pairs to
make a convenient connection between 3/4" (Sears
42-34405) or 1" (Sears 42-34407) house plumbing
(copper, CPVC or PEX) and the Central Water Whole
Home Filtration System.
1. Follow the instructions included with the Sears flexible
connectors.
Soldered Copper Pipe
1. Thoroughly clean and apply solder flux to all joints.
2. Make all solder connections.
IMPORTANT: Do not solder with plumbing attached to
installation Adapters and single valve
bypass. Soldering heat will damage the
adaptors and valve.
Threaded Pipe
1. Apply pipe joint compound or Teflon® tape to all
male pipe threads.
2. Tighten all threaded joints and make all solder con-
nections.
CPVC Plastic Pipe
1. Clean, prime and cement all joints, following the
manufacturer's instructions supplied with the plastic
pipe and fittings.
Other, including PEX (Crosslinked Polyethylene)
1. Follow the piping system manufacturer's instructions
when using other pipe approved for potable water.
® Teflon is a registered trademark of E.I. Du Pont de Nemours
and Company.
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
9
METALWATERPIPEGROUNDING
IMPORTANT: This Central Water Whole Home Filter
has a non-metallic valve system.
Installing it on metal plumbing will break
electrical continuity, which may interrupt
grounding for the home. You must restore
electrical continuity in your metal plumb-
ing system.
If you installed a 3-valve bypass system (Fig. 7), electri-
cal continuity will be maintained. If you installed the
non-metallic bypass valve (Fig. 8), restore the ground as
follows:
Install a #4 copper wire (parts not included) across the
removed section of metal water pipe, securely clamping
it at both ends (See Fig. 9). Be sure the pipes are clean
under the clamps, to assure good contact.
NOTE: If you are installing a water softener or other
item(s) into the plumbing system, along with the
Central Water Whoel Home Filter, be sure to
restore electrical continuity across all removed
metal pipe sections.
INSTALL VALVE DRAIN HOSE
1. Measure, cut to needed length and connect the 3/8"
drain line (provided) to the Central Water Whole
Home Filtration System valve drain fitting (See Figure
10). Use a hose clamp to hold the hose in place.
NOTE: If codes require a rigid drain line see "Valve
Drain requirements" section.
2. Run the drain hose or copper tubing to the floor
drain. Secure drain hose. This will prevent the drain
line from "whipping" during Clean Rinse cycles. See
"Air Gap Requirements" section.
METAL PIPE GROUNDING
(parts not included)
Ground Wire
/
Figure 9
Drain Line
Connection
SINGLE BYPASS VALVE
Pull handle
OUT for normal
I Push handle IN
I for BYPASS
Figure 10
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
10
TEST FOR LEAKS
1. Make sure the single bypass valve (or 3 valve bypass,
if installed) is in the bypass position, with the handle
pushed in (See Figure 10).
2. Fully open the main water supply valve.
3. Briefly open a faucet in the house to refill the plumb-
ing with water.
4. Slowly move the bypass valve(s) to the normal oper-
ation position, pausing several times to allow the unit
to pressurize slowly (See Figure 10).
5. Check for leaks at all the plumbing connections you
made.
IMPORTANT: Start up procedure must be run prior to
using any filtered water. Follow the
instructions below and on Page 13.
TURN ON THE CENTRAL WATER WHOLE
HOME FILTRATION SYSTEM
During installation, the Central Water Whole Home
Filtration System wiring may be moved or jostled from
place. Check to be sure all leadwire connectors are
secure on the back of the electronic board (see Figure
25 on Page 23) and be sure all wiring is away from the
valve gear and motor area, which rotates during Clean
Rinse cycles.
1. Plug the Central Water Whole Home Filtration
System's transformer into an electrical outlet that is
not controlled by a switch.
2. In the display, the words "SET TIME" appear and
12:00 PM begins to flash. Set the clock according to
the "Set Time of Day" section on Page 12.
3. Run the start up procedure, as detailed on Page 13.
NORMAL OPERATION
During normal operation water enters the Central
Water Whole Home Filtration System and flows
through several filtration processes where tastes, odors
and sediment are reduced.
CLEAN RINSE CYCLE
A Clean Rinse cycle will automatically be initiated
based on how many gallons of water have been fil-
tered through the system (or after 14 days if no water
has passed through the system in that time). The Clean
Rinse cycle lifts and expands the media bed to rejuve-
nate the media and then repacks the bed for continued
use. During the Clean Rinse cycle, dirt, sediment, etc.
are flushed from the Central Water Whole Home
Filtration System down the drain.
APPLICATIONS FOR A CENTRAL WATER
FILTRATION SYSTEM
Do not use the Central Water Whole Home
Filtration System with water that is microbiologically
unsafe or of unknown quality without adequate dis-
infection before or after the system.
The Central Water Whole Home Filtration System
may not be an effective treatment method for water
sources with a hydrogen sulfide problem (rotten egg
odor or taste). If your water has hydrogen sulfide,
contact your local Sears store associate for Kenmore
solutions.
The Central Water Filtration System will not remove
iron and is not intended to replace iron treatment
equipment.
Although the Central Water Filtration System has
sediment filter capabilities, additional sediment fil-
tration may be needed in problem water applica-
tions.
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
11
Display
Central Water
Whole Home Filtration System
UP
button
CLEAN
DOWN
button
CLEAN
button
ENTER
button
Figure 11
When the transformer is initially plugged into the electri-
cal outlet, the model code (dF 1) and a test number
(example: J2.0), are briefly shown in the faceplate dis-
play. Then the words "SET TIME" appear and 12:00 PM
begins to flash.
NOTE: If "- - - -" shows in the display, press the f UP or
V DOWN button until "dF 1" shows in the dis-
play. Then, press the ENTER button to set, and
change to the "SET TIME" display.
CODE
dF
Figure 12
SET CURRENT TIME
If the words "SET TIME" do not show in the display, press
the ENTER button a few times until they do.
1. Press the /X UP or V DOWN buttons to set the pres-
ent time. Up moves the display ahead; down sets the
time back. Be sure AM or PM is correct.
NOTE: Press buttons and quickly release to slowly
advance the display. Hold the buttons down for
fast advance.
2. When the correct time is displayed, press the ENTER
button a few times, until the time appears in the dis-
play, but is not flashing.
I
TIME
i-I,__-II__I'IZ.3 AM
SET
TIME
I
C IC
Figure 13
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
12
IMPORTANT:
Run the start up cycle immediately after com-
pleting installation, before using any water in
the home.
The filtration media in this Central Water Whole Home
Filtration System contains a small number of harmless
activated carbon particles generated during shipping
that are small enough to exit the system with water
flow. It is normal for these particles to cause a tempo-
rary discoloration of the water coming out of the sys-
tem. To avoid discolored water at your home's faucets
the system's start up cycle should be initiated to rinse
the particles and any discolored water down the drain.
If the Central Water Whole Home Filtration System is
used without first running the start up cycle, you will
notice that the water will temporarily have a gray color
until the particles have exited the system.
To Initiate the start up cycle:
1. Make sure the drain hose is attached to the Central
Water Whole Home Filtration System and the other
end is secured over a drain (see "Install Valve Drain
Hose" on Page 10).
2. Make sure bypass valve is in the "service" (open or
filtered water) position and the home's water supply
is turned on.
3. Press and hold the CLEAN button to initiate the start
up cycle. The button can be released when you hear
the valve changing position and "RECHARGE NOW"
flashes in the display.
During the start up cycle:
Throughout the start up cycle you will hear the valve
changing position and notice the flow of water to drain
starting and stopping. The start up cycle will take
approximately 20 minutes. Avoid using water during
this time. Do not set the time of day or press other but-
tons during the start up cycle, as this will interrupt the
start up cycle. Do not unplug the transformer during
the start up cycle. If the start up cycle is interrupted, it
should be initiated again and allowed to run to comple-
tion.
After the start up cycle:
Once the start up procedure completes successfully, it
cannot be initiated a second time. The Central Water
Whole Home Filtration System will automatically return
to the normal operation position. Once the start up
cycle has run, a faucet in the home should be opened
and water allowed to run for 10 minutes at the system's
rated flow. If, after running the start up cycle, the
water still appears discolored, manually run Clean Rinse
cycles (See Page 14) until the water is clear.
If the time of day was not set before the start up cycle,
set it now (See Page 12).
Check the new plumbing connections and joints once
more for leaks.
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
13
STARTA CLEANRINSECYCLE
To manually start a Clean Rinse cycle, press and hold the CLEAN button
for a few seconds, until "RECHARGE NOW" flashes in the display. This
Clean Rinse cycle takes 3 minutes (unless the factory settings for backwash
and fast rinse times have been changed, as shown below).
SET CLEAN RINSE START TIME
By default the Central Water Whole Home Filtration System will Clean
Rinse at 1:00 a.m. The system will not filter water during the Clean Rinse
cycle. It is recommended that the Clean Rinse start time be set for when
water is not likely to be used in the household.
NOTE: If you also have a water softener, set the Central Water System's
Clean Rinse time for either one hour before or two hours after the
water softener's scheduled regeneration time.
To change the Clean Rinse start time:
1. Press the ENTER button a few times until "SET RECHARGE TIME" is
shown in the display.
2. Press the f UP or V DOWN buttons to set the Clean Rinse time in 1
hour increments. Be sure AM or PM is correct.
3. When the desired Clean Rinse time is displayed, press the ENTER button
a few times, until the time appears in the display, but is not flashing.
RECHARGE
NOW
Figure 14
RECHARGE
TIME
I.FtI-I
I'UU AM
Figure 15
SET LENGTH OF CLEAN RINSE
By default the Central Water Whole Home Filtration System's Clean Rinse
cycle will consist of a 2 minute backwash followed by a 1 minute fast rinse.
This should be sufficient for most applications.
Increasing the length of Clean Rinse time will increase the amount of water
flushed to drain during each Clean Rinse cycle. Increasing the length of
Clean Rinse should only be done in cases of very high amounts of sedi-
ment, or other water issues.
To change the length of the backwash or fast rinse parts of the Clean
Rinse cycle:
1. Press and hold the ENTER button for a few seconds, until the "000--"
screen appears, as shown at right.
2. Press the ENTER button once, so "SET TIME bA" appears in the display.
3. Press the f UP or V DOWN buttons to set the length of backwash in
minutes.
4. Press the
TIME Fr"
5. Press the
minutes.
.
ENTER button when the desired backwash time is shown. "SET
appears in the display.
f UP or V DOWN buttons to set the length of fast rinse in
Press the ENTER button when the desired fast rinse time is shown. The
display will change to the time of day.
FIFI Fi ____
UUU
TIME
LO
I II!
m
SET
TIME
Fr'- I
Figure 16
Questions? Call The I<enmore Water Line 1-800-426-9345 or visit KenmoreWater.com
14
SETTING THE FREQUENCY OF AUTOMATIC CLEAN RINSE CYCLES
The Central Water Whole Home Filtration System will automatically initiate
Clean Rinse cycles based on how much water has been filtered through the sys-
tem. The default is to run a Clean Rinse cycle after 3,000 gallons have been
filtered. The Clean Rinse cycle takes place at the preset time of day (1:00 a.m.
is the default). The system also will initiate an automatic Clean Rinse cycle if
no water has been run through the system in 14 days, to keep the filter bed
fresh.
The Central Water Whole Home Filtration System allows the frequency of
automatic Clean Rinse cycles to be increased for systems where the water sup-
ply may have more sediment than in a typical municipal water supply. The
table below shows the three settings available. The unit is shipped with "CLn 1"
as the default.
Clean Rinse Clean Rinses
Water supply type
mode every
CLn 1 City water supply 3,000 gallons
Well water with a
CLn 2 2,000 gallons
light amount of sediment
Well water with a
CLn 3 1,000 gallons
high amount of sediment
To change the frequency of Clean Rinse cycles:
1. Press the ENTER button a few times until "SET CLn" is shown in the display,
along with a flashing number (1 - 3). The flashing number indicates the cur-
rent setting.
2. Press the /_ UP or V DOWN buttons to change the number to the desired
Clean Rinse mode (see table, above).
3. Press the ENTER button when the desired Clean Rinse mode is displayed.
The display will change to the time of day.
SET
V!
LLn !
SET
I!-!
If..I.. 2
-SET
I-!
LLI-I
Figure 17
Questions? Call The I<enmore Water Line 1-800-426-9345 or visit I<enmoreWater.com
15
OPERATING IN MANUAL CLEAN RINSE MODE
Clean Rinse cycles will run automatically, unless the automatic Clean Rinse
function has been disabled. If this function has been disabled, it will be nec-
essary to manually initiate any Clean Rinse cycles. It is recommended that a
Clean Rinse cycle should be run at least once each month, or more frequently
if necessary.
A manual Clean Rinse mode may be used when a drain (required for auto-
matic Clean Rinse) is not available. However, it is recommended that auto-
matic Clean Rinse be used if the drain requirements can be met.
IMPORTANT: During the Clean Rinse cycle, whether manually or automati-
cally initiated, water will flow from the valve drain port at 3.4 gallons per
min. for 3 minutes. If a permanent drain line has not been installed, provi-
sions must be made for the drain flow prior to initiating a Clean Rinse cycle
You must have empty containers ready that will hold at least 15 gallons of
water.
DISABLING AUTOMATIC CLEAN RINSE
To disable the automatic Clean Rinse function:
1. Press and immediately release the CLEAN button (pressing and holding the
button a few seconds would initiate a Clean Rinse cycle).
2. "RECHARGE OFF" will flash in the display, as shown in Figure 18, indicat-
ing that the Central Water Whole Home Filtration System is in the manual
Clean Rinse mode (the automatic Clean Rinse function has been disabled).
MANUALLY STARTING A CLEAN RINSE CYCLE
To manually start a Clean Rinse cycle:
1. If the drain line is not set up to discharge into a drain, you must have
empty containers ready that will hold at least 15 gallons of water.
2. Press and hold the CLEAN button for a few seconds, until "RECHARGE
NOW" flashes in the display, as shown in Figure 19.
3. When the Clean Rinse cycle is complete, the Central Water Whole Home
Filtration System will remain in the manual Clean Rinse mode.
RE-ENABLING AUTOMATIC CLEAN RINSE
To return the Central Water Whole Home Filtration System to its automatic
Clean Rinse function:
1. Press and immediately release the CLEAN button.
2. The flashing "RECHARGE OFF" on the display should be replaced by the
normal time of day screen, as shown in Figure 20.
RECHARGE
Figure 18
RECHARGE
NOW
Figure 19
.
C.UC I
IZ.I" IZ.I pM
Figure 20
Questions? Call The I<enmore Water Line 1-800-426-9345 or visit KenmoreWater.com
16
POWER OUTAGE MEMORY
If electrical power to the Central Water Whole Home
Filtration System is lost, "memory" built into the con-
troller circuitry will keep all settings for several hours.
While the power is out, the display is blank and the
Central Water Whole Home Filtration System will not
Clean Rinse.
When electrical power is restored, you have to reset the
time of day only if the display is flashing. The Clean
Rinse TIME never requires resetting unless a change is
desired. Even if the clock is incorrect after a long
power outage, the Central Water Whole Home
Filtration System works as it should to keep your water
treated. However, Clean Rinse cycles may occur at the
wrong time of day until you reset the clock to the cor-
rect time of day.
NOTE: If the Central Water Whole Home Filtration
System was in a Clean Rinse cycle when power
was lost, it will now finish the cycle.
VACATIONS AND EXTENDED PERIODS OF
NO WATER USE
If your Central Water Whole Home Filtration System
will not be used for an extended period of time (several
months), please follow one of these recommendations:
If the water supply to the unit is not turned off, and
the automatic Clean Rinse function has not been dis-
abled, then no further actions are required. The
Central Water Filtration System will clean itself
every 14 days if no water has run through it.
If you do not want Clean Rinse cycle to be running
automatically while you are gone, it is recommended
that you unplug the Central Water Whole Home
Filtration System and either shut off the water supply
or place the bypass valve(s) into the bypass position.
If the Clean Rinse cycle cannot be automatically run,
due to the water supply being shut off, the trans-
former being unplugged or the automatic Clean
Rinse function being disabled, then it is recommend-
ed that a minimum of 2 manually initiated Clean
Rinse cycles be performed when the system is
placed back into operation (see Start a Clean Rinse
Cycle section on Page 14).
In any installation where there is a possibility of
freezing, the Central Water Filtration System should
be disconnected and the water drained (see Protect
the Central Water Whole Home Filtration System
from Freezing section on Page 18).
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
17
PROTECT THE CENTRAL WATER FILTRATION
SYSTEM FROM FREEZING
If the Central Water Whole Home Filtration System is
installed where it could freeze (summer cabin, lake
home, etc.), you must drain all water from it to stop
possible freeze damage. If the system freezes, cracks
may develop in plastic parts, which will leak causing
damage.
To drain the unit:
1. Close the shut-off valve on the house main water
pipe, near the water meter or pressure tank.
2. Open a faucet in the filtered water pipes to vent
pressure in the unit.
3. Move the stem in the single bypass valve to bypass.
Close the inlet and outlet valve in a 3 valve bypass
system, and open the bypass valve. If you want
water in the house pipes again, reopen the shut-off
valve on the main water pipe.
4. Unplug the transformer at the wall outlet. Take off
the drain hose if it will interfere with moving the
Central Water Whole Home Filtration System into
position over the drain.
5. Remove the large holding clips at the Central Water
Whole Home Filtration System inlet and outlet (See
Figure 8 on Page 8). Separate the unit from the
plastic installation adaptors, or from the bypass
valve.
6. Lay a piece of 2 inch thick board near the floor
drain (See Figure 21).
7. Move the Central Water Whole Home Filtration
System close to the drain. Slowly and gently, tip it
over until the rim rests on the wood block with the
inlet and outlet over the drain (See Figure 21). Do
not allow the unit's weight to rest on the inlet and
outlet fittings or they may break.
8. Tip the bottom of the Central Water Whole Home
Filtration System up a few inches and rest it on
something like a wood block that will allow water to
drain. Rest the bottom on two stacked wood blocks.
Leave the unit laying like this until you are ready to
use it. Plug the inlet and outlet with clean rags to
keep dirt, bugs, etc. out.
DRAIN ALL WATER FROM CENTRAL WATER
FILTRATION SYSTEM
Wood Block
Floor Drain
Figure 21
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
18
PROBLEM CAUSE CORRECTION
Water has black or gray (NEW SYSTEM) Start up procedure Run start up procedure (See Page 13) or run
color has not been completed consecutive Clean Rinse cycles (See Page 14)
until water color returns to normal.
(NOT A NEW SYSTEM) Normal abra-
sion of filtration media
Sediment filter screen is cloggedLow water pressure at
house faucets
Filtration media pores are blocked
Water has objectionable System is in bypass
taste and/or odor
Filtration media pores are blocked
Manually initiate a Clean Rinse cycle (See
Page 14).
Manually initiate a Clean Rinse cycle (See
Page 14).
If the filter screen is frequently plugging, it
may be necessary to adjust the frequency of
Clean Rinse cycles or add a sediment filter
upstream (See Figure 2 on Page 5).
Manually initiate a Clean Rinse cycle (See
Page 14).
If the filtration media pores are frequently
blocking, it may be necessary to increase the
frequency of Clean Rinse cycles or add a
sediment filter upstream (See Figure 2 on
Page 5).
Move bypass valve(s) to normal operating
(non-bypass) position.
Manually initiate a Clean Rinse cycle (See
Page 14).
If the filtration media pores are frequently
blocking, it may be necessary to increase the
frequency of Clean Rinse cycles or add a
sediment filter upstream (See Figure 2 on
Page 5).
Move bypass valve(s) to normal operating
(non-bypass) position.
Clean drain flow control (See Page 21).
No water flow to drain System is in bypass
during Clean Rinse cycle
Drain flow control is plugged
Drain hose is plugged or kinked Straighten drain hose.
Transformer is unplugged from wall Check for loss of power and correct.
electrical outlet (display will be blank)
Clean Rinse cycle does If display reads "RECHARGE OFF", Press and release the CLEAN button until
not run automatically then Clean Rinse function has been display no longer reads "RECHARGE OFF"
disabled (See Page 16).
Check for loss of power.
Reset the clock to the correct time of day (See
Page 12).
If display is blank, transformer may be
unplugged from wall electrical outlet
If time display is flashing, then a long
power loss caused the clock to lose its
time setting
Motor is defective or inner valve
defect is causing high torque on the
motor
Clean Rinse cycle does
not run at the
programmed time of day
Valve motor stalled or
clicking
Replace rotor/seal kit (instructions included
with kit).
Replace motor and switch (See parts list at
end of this manual).
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com
19
PROBLEM CAUSE CORRECTION
"RECHARGE OFF" is The automatic Clean Rinse function If you want the Clean Rinse function to run
flashing in the display has been disabled (See Page 16) automatically, press and release the CLEAN
button until display no longer reads
"RECHARGE OFF" (See Page 16).
Error Code El, E3 or E4 Wiring harness or connections to Replace wiring harness or connection to
appears position switch position switch (See parts list at end of this
manual).
Switch Replace switch (See parts list at end of this
manual).
Valve defect causing high torque Replace rotor/seal kit (instructions included
with kit).
Motor inoperative Replace motor (instructions included with
motor)
Error Code E5 appears Electronic control Replace electronic control board (PWA)
(instructions included with PWA).
Procedure for removing error code from display:
1. Unplug transformer from electrical outlet.
2. Correct problem.
3. Plug in transformer.
4. Wait 8 minutes. The error code will return if the problem was not corrected.
Assistance from customer service may be needed with the following:
PROBLEM CAUSE CORRECTION
Water running to the drain Inner valve defect causing leak Replace seals and rotor
(while unit is not in the
Clean Rinse cycle)
Filter media in household Crack in distributor or riser tube Replace distributor or riser tube.
plumbing
Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com