Barco Presentation and Simulation
SERVICE INFORMATION BULLETIN INFO T
Serial number:567
Date: 10052004
Product: iQ Airflow Circuit adaptation
InfoT Priority Code
A
”Must” modification, Barco will provide the necessary components to perform this modification
at no charge.
B
Improve s the reliability of t he product.
C Improves the general working conditions of the product.
D
For information only.
AIRFLOW SENSING CIRCUIT ADAPTATION FOR UN-
WANTED AIRFLOW ERRORS
Priority assessment
A B
C
D
Introduction: Airflow error
Airflow measure
In the Barco iQ projectors the airflow sensor R763593 mounted on the top cover of the projector is used
to measure the airflow in the projector. The airflow sensor is pre heated and measures the temperature
of the air taken in at the XCube that is cooling the analyzers, polarisers and LCD panels.
This airflow temperature signal will be compared to the ambient temperature signal in the Power box and
will generate an airflow error (appearing also on the screen) signal in case of :
• insufficient airflow due to dirty dust filters
•blockedfan
A group of resistors is mounted (R11–R22) on the airflow module.
Field experienceshowedthatin iQ projectors using the 250W lamp (at high temperature) unwanted
airflow error s may occur even when in presen ce of clean d u st filters.
Note that when disconnecting (or in case of a bad connection ! ) the connector linking
the keypad and the airflow sensor module to the PMP, image -4,the warning will also
appear on the screen.
Serial number: 567 1 Printed inBelgium