Table 2: Status LEDs
Number Function Color Meaning
1
OFF state Red Lights up red when at least one
s
afety output is in the OFF state.
2
ON state Green Lights up green when at least one
safety output is in the ON state.
3
Warning field Yellow Shines yellow if at least one warning
field is interrupted.
4
Restart interlock Yellow Setup with reset: Flashes if the
r
estart interlock has been triggered.
Configuration with automated restart
after a time: Lights up while the con‐
figured time to restart expires.
The OFF state and ON state light emitting diodes can be found in multiple locations on
t
he safety laser scanner. 3 additional sets are arranged in pairs on the base of the
optics cover. So the light emitting diodes can also be seen in many cases when it is not
possible to see the display, e.g. due to the mounting situation or because it is hidden
from the operator’s position.
The device has different light emitting diodes for every network interface. These net‐
work light emitting diodes are located below the display.
More information about the meaning of the light emitting diodes see "Diagnostic LEDs",
page 141.
Depending on the configuration, the display shows current information about the safety
laser scanner’s status, see "Buttons and display", page 128.
3.2.4 Connections
microScan3 – PROFINET (RJ45):
•
1 x f
emale connector, M12, L-coding for voltage supply
•
2 x female connector, RJ45 for push-pull male connector for ethernet (PROFINET
PROFIsafe, data output, configuration and diagnostics)
•
1 × female connector, USB 2.0 Mini-B for configuration and diagnosis
1)
microScan3 – PROFINET (SCRJ):
•
1 x female connector, M12, L-coded for voltage supply
•
2 × female connector, SCRJ (optical fibers), for Push-Pull male connector for Ether‐
net (PROFINET PROFIsafe, data output, configuration and diagnostics)
•
1 × female connector, USB 2.0 Mini-B for configuration and diagnosis
1)
microScan3 – PROFINET (M12):
•
1 x male connector, M12, A-coding for voltage supply
•
2 x female connector, M12, D-coded for Ethernet (PROFINET PROFIsafe, data out‐
put, configuration and diagnostics)
•
1 × female connector, USB 2.0 Mini-B for configuration and diagnosis
1)
3.2.5 System plug
A system plug is required to operate the safety laser scanner.
T
he metal plate with the connections is the system plug (see figure 4, page 15). The
system plug can either be mounted on the rear side or the underside.
The safety laser scanner’s internal configuration memory is integrated in the system
plug. The system plug and all connecting cables can remain at the installation site
when the safety laser scanner is replaced. The system plug is detached from the defec‐
1)
T
he USB connection may only be used temporarily and only for configuration and diagnostics.
PRODUCT DESCRIPTION 3
8021219/15ZV/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
17
Subject to change without notice