LG AUUQ18GH1.AWGBBRZ Owner's manual

Category
Split-system air conditioners
Type
Owner's manual
Air Conditioner
SVC MANUAL(General)
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Internal Use Only
http://biz.lgservice.com
- 2 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Air Conditioner Service Manual
TABLE OF CONTENTS
Part 1 General Information ..........................................................................................................3
1. Safety Precautions........................................................................................................4
2. Model Line Up................................................................................................................7
3. Nomenclature ................................................................................................................9
Part 2 Functions & Controls......................................................................................................10
1. List of Functions & Accessory...................................................................................11
2. Air Flow .......................................................................................................................15
3. Air Purifying.................................................................................................................17
4. Installation Functions.................................................................................................18
5. Reliability .....................................................................................................................24
6. Convenience Functions & Controls .........................................................................25
7. Special Function & KIT...............................................................................................33
Part 3 Basic Control ..................................................................................................................36
1. Normal operation ........................................................................................................37
2 Compressor control ....................................................................................................37
3. EEV( Electronic Expansion Valve) control ...............................................................37
Part 4 Trouble Shooting Guide ...............................................................................................38
1. Self-diagnosis Function ............................................................................................39
2. Pump Down ................................................................................................................41
3. Evacuation (All amount of refrigerant leaked) ........................................................42
4. Gas Charging (After Evacuation)..............................................................................43
5. Cycle Part....................................................................................................................44
6. Electronic Parts..........................................................................................................45
- 3 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Safety Precautions ............................................................................................................4
2. Model Line Up .....................................................................................................................7
3. Nomenclature....................................................................................................................10
Part 1 General Information
- 4 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 1 General Information
1. Safety Precautions
1.1 Cautions in Repair
To prevent injury to the user or other people and property damage, the following instructions must be followed.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the follow-
ing indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
n Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
Dangerous Voltage
Be sure to disconnect the power cable plug from the plug socket before disas-
sembling the equipment for a repair.Internal components and circuit boards are at
main potential when the equipment is connected to the power cables. This volt-
age is extremely dangerous and may cause death or severe injury if come in con-
tact with it.
Do not touch the discharging refrigerant gas during the repair work.
The discharging refrigerant gas.The refrigerant gas can cause frostbite.
Release the refrigerant gas completely at a well-ventilated place first.
Otherwise, when the pipe is disconnected, refrigerant gas or refrigerating
machine oil discharges and it Can cause injury.
When the refrigerant gas leaks during work, execute ventilation. If the refrigerant
gas touches to a fire, poisonous gas generates. A case of leakage of the refriger-
ant and the closed room full with gas is dangerous because a shortage of oxygen
occurs. Be sure to execute ventilation.
When removing the front panel or cabinet, execute short-circuit and discharge
between high voltage capacitor terminals. If discharge is not executed, an electric
shock is caused by high voltage resulted in a death or injury.
Do not turn the air-conditioner ON or OFF by plugging or unplugging the power
plug. There is risk of fire or electrical shock.
- 5 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 1 General Information
Do not turn on the breaker under condition that front panel and cabinet are
removed.
Be sure to earth the air conditioner with an earthing conductor connected to the
earthing terminal.
Conduct repair works after checking that the refrigerating cycle section has
cooled down sufficiently. Otherwise, working on the unit, the hot refrigerating
cycle section can cause burns.
Do not tilt the unit when removing panels. Otherwise, the water inside the unit
can spill and wet floor.
Do not use the welder in a well-ventilated place. Using the welder in an enclosed
room can cause oxygen deficiency.
Be sure to turn off power switch before connect or disconnect connector, or parts
damage may be occurred.
Do not use a defective or underrated circuit breaker. Use the correctly rated
breaker and fuse. Otherwise there is a risk of fire or electric shock.
Install the panel and the cover of control box securely. Otherwise there is risk of
fire or electric shock due to dust, water etc.
Indoor/outdoor wiring connections must be secured tightly and the cable should
be routed properly so that there is no force pulling the cable from the connection
terminals. Improper or loose connections can cause heat generation or fire.
Do not touch, operate, or repaire the product with wet hands. Hoding the plug by
hand when taking out. Otherwise there is risk of electric shock or fire.
Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air
purge. Do not compress air or Oxygen and Do not use Flammable gases.
Otherwise, it may cause fire or explosion.
- There is the risk of death, injury, fire or explosion.
- 6 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 1 General Information
1.2 Inspections after Repair
Check to see if the parts are mounted correctly and wires are connected.
Improper installation and connections can cause an electric shock or an injury.
Check the installation platform or frame has corroded. Corroded installation plat-
form or frame can cause the unit to fall, resulting in injury.
Be sure to check the earth wire is correctly connected.
After the work has finished, be sure to do an insulation tset to check the resis-
tance is 2[Mohm] or more between the charge section and the non-charge metal
section (Earth position). If the resistance value is low, a disaster such as a leak or
electric shock is caused at userʼs side.
Check the drainage of the indoor unit after the repair. If drainage is faulty the
water to enter the room and wet floor.
Check to see if the power cable plug is not dirty or loose. If the plug is dust or
loose it can cause an electrical shock or fire.
Do not use a joined power cable or extension cable, or share the same power
outlet with other electrical appliances. otherwise, it can cause an electrical shock,
excessive heat generation or fire.
Do not insert hands or other objects through the air inlet or outlet while the prod-
uct is operating. There are sharp and moving parts that could cause personal
injury.
Do not block the inlet or outlet of air flow. It may cause product failure
- 7 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
2. Model Line Up
Part 1 General Information
2.1 Indoor units
Category Type Chassis
Model Name
Capacity class, kW
5.0 6.0 7.0 10.5 12.5 14.1 15.8
Ceiling
cassette
4way
TP
ATNQ18GPLE3 ATNQ21GPLE3
TN
ATNQ24GNLE3
TM
ATNQ36GMLE3 ATNQ42GMLE3 ATUQ48GMLE3 ATUQ54GMLE3
Ceiling suspended
VJ
AVNQ18GJLA0 AVNQ21GJLA0 AVNQ24GJLA0
VK
AVNQ36GKLA0
VL
AVNQ42GLLA0 AVUQ48GLLA0 AVUQ54GLLA0
Ceiling
concealed
duct
High
static
pressure
BH
ABNQ18GHLA0 ABNQ21GHLA0
BG
ABNQ24GGLA0 ABNQ36GGLA0
BR
ABNQ42GRLA0 ABUQ48GRLA0 ABUQ54GRLA0
Low
static
pressure
L2
ABNQ18GL2A0 ABNQ21GL2A0
L3
ABNQ24GL3A0
- 8 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 1 General Information
2.2 Outdoor units
Model Names
AUUQ18GH1
ATUQ18GPLE3
AVUQ18GJLA0
ABUQ18GHLA0
ABUQ18GL2A0
AUUQ21GH1
ATUQ21GPLE3
AVUQ21GJLA0
ABUQ21GHLA0
ABUQ21GL2A0
AUUQ24GH1
ATUQ24GNLE3
AVUQ24GJLA0
ABUQ24GGLA0
ABUQ24GL3A0
No. of connectable indoor units 1
Total capacity class index of
Connectable Indoor units
kW 5.0 6.0 7.0
Connectable indoor unit model names
ATNQ18GPLE3
AVNQ18GJLA0
ABNQ18GHLA0
ABNQ18GL2A0
ATNQ21GPLE3
AVNQ21GJLA0
ABNQ21GHLA0
ABNQ21GL2A0
ATNQ24GNLE3
AVNQ24GJLA0
ABNQ24GGLA0
ABNQ24GL3A0
Power supply
220-240V, 1Ø, 50Hz
220V, 1Ø, 60Hz
Chassis
Model Names
AUUQ36GH1
ATUQ36GMLE3
AVUQ36GKLA0
ABUQ36GGLA0
AUUQ42GH1
ATUQ42GMLE3
AVUQ42GLLA0
ABUQ42GRLA0
AUUQ48GH1
ATUQ48GMLE3
AVUQ48GLLA0
ABUQ48GRLA0
AUUQ54GH1
ATUQ54GMLE3
AVUQ54GLLA0
ABUQ54GRLA0
No. of connectable indoor units 1
Total capacity class index of
Connectable Indoor units
kW 10.5 12.5 14.1
15.8
Connectable indoor unit model names
ATNQ36GMLE3
AVNQ36GKLA0
ABNQ36GGLA0
ATNQ42GMLE3
AVNQ42GLLA0
ABNQ42GRLA0
ATUQ48GMLE3
AVUQ48GLLA0
ABUQ48GRLA0
ATUQ54GMLE3
AVUQ54GLLA0
ABUQ54GRLA0
Power supply
220-240V, 1Ø, 50Hz
220V, 1Ø, 60Hz
Chassis
- 9 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
3. Nomenclature
3.1 Indoor Unit(Global)
A T N Q24 G N L E 3
Serial Number
Functions
A : Basic
E : Elevation grille
Look : Basic
Chassis Name
Electrical Ratings
G : 220-240V, 1Ø, 50Hz / 220V, 1Ø, 60Hz
Capacity Code based on ‘kBtu/h’ units
Model Type
Q: Cooling Only
R410A Single A Indoor Unit
ATN : Ceiling cassette type indoor unit
AVN : Convertible, Ceiling and Floor type indoor unit
ABN : Ceiling concealed duct type indoor unit
A U U Q24 HG 1
Serial Number
High Efficiency model
Electrical Ratings
G : 220-240V, 1Ø, 50Hz / 220V, 1Ø, 60Hz
Capacity code
Model Type
Q : Cooling Only
R410A Single A Outdoor Unit
Part 1 General Information
- 10 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 2 Functions & Controls
1. List of Functions & Accessory ......................................................................................11
2. Air flow ............................................................................................................................15
2.1 Auto swing (left & right)...............................................................................................15
2.2 Auto swing (up & down) ..............................................................................................15
2.3 Chaos swing (up/down)...............................................................................................15
2.4 Air flow step.................................................................................................................16
2.5 Chaos wind (auto wind)...............................................................................................16
2.6 Jet Cool Mode Operation ............................................................................................16
2.7 Swirl wind Swing .........................................................................................................16
3. Air purifying ....................................................................................................................17
3.1 PLASMA Air Purifying System ....................................................................................17
4. Installation Functions ....................................................................................................18
4.1 E.S.P. (External Static Pressure) Setting ....................................................................18
4.2 High Ceiling operation.................................................................................................23
5. Reliability ........................................................................................................................24
5.1 Hot start.......................................................................................................................24
5.2 Self-diagnosis Function...............................................................................................24
6. Convenience Functions & Controls .............................................................................25
6.1 Cooling Operations .....................................................................................................25
6.2 Auto cleaning operation ..............................................................................................26
6.3 Auto changeover operation.........................................................................................26
6.4 Child Lock Function.....................................................................................................27
6.5 Group Control..............................................................................................................28
6.6 Sleep Timer Operation ................................................................................................29
6.7 Timer(On/Off) ..............................................................................................................29
6.8 Weekly Program..........................................................................................................30
6.9 Two Thermistor Control...............................................................................................32
7. Special Function & KIT ..................................................................................................33
7.1 Low Ambient control....................................................................................................33
7.2 Space Control .............................................................................................................33
7.3 Auto Elevation Grille....................................................................................................33
Part 2 Functions & Controls
- 11 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Category Functions
ATNQ18GPLE3
ATNQ21GPLE3
ATNQ24GNLE3
ATNQ36GMLE3
ATNQ42GMLE3
ATNQ48GMLE3
ATNQ54GMLE3
Air flow
Air supply outlet 4
Airflow direction control (left & right) X
Airflow direction control (up & down) Auto
Auto swing (left & right) X
Auto swing (up & down) O
Airflow steps (fan/cool/heat) 4 / 5 / 4
Chaos wind(auto wind) O
Jet cool/heat O / X
Swirl wind O
Air purifying
Triple filter (Deodorizing) X
Plasma air purifier PTPKM0
Allergy Safe filter X
Long-life prefilter (washable / anti-fungus) O
Installation
Drain pump O
E.S.P. control* X
Electric heater X
High ceiling operation* O
Auto Elevation Grille* PTEGM0
Reliability
Hot start O
Self diagnosis O
Soft dry operation O
Convenience
Auto changeover** O**
Auto cleaning X
Auto operation(artificial intelligence)** O**
Auto Restart O
Child lock* O
Forced operation O
Group control* O
Sleep mode O
Timer(on/off) O
Timer(weekly)* O
Two thermistor control* O
Individual
control
Wired remote controller O
Deluxe wired remote controller PQRCUDS0 / PQRCUDS0B / PQRCUDS0S
Simple wired remote controller PQRCVCL0Q / PQRCVCL0QW
Simple Wired remote controller(for hotel use)
PQRCHCA0Q / PQRCHCA0QW
Wireless remote controller PQWRHDF0
CAC network
function
General central controller (Non LGAP) X
Network Solution(LGAP) O
Dry contact PQDSA(1)/PQDSB(1) / PQDSBC
PI 485(for Indoor Unit) X
Special
function kit
Zone controller X
CTI(Communication transfer interface) X
Electronic thermostat X
Others
Remote temperature sensor PQRSTA0
Telecom shelter controller X
Part 2 Functions & Controls
1. List of Functions & Accessory
1. 4-Way Ceiling Cassette Indoor
- 12 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 2 Functions & Controls
2. Ceiling Concealed Duct Indoor
Category Functions
ABNQ18GHLA0, ABUQ18GL2A0
ABNQ21GHLA0, ABUQ21GL2A0
ABNQ24GGLA0, ABUQ24GL3A0
ABNQ36GGLA0
ABNQ42GRLA0
ABNQ48GRLA0
ABNQ54GRLA0
Air flow
Air supply outlet 2
Airflow direction control (left & right) X
Airflow direction control (up & down) X
Auto swing (left & right) X
Auto swing (up & down) X
Airflow steps (fan/cool/heat) 3 / 3 / 3
Chaos wind(auto wind) X
Jet cool/heat O / X
Swirl wind X
Air purifying
Triple filter (Deodorizing) X
Plasma air purifier X
Allergy Safe filter X
Long-life prefilter (washable / anti-fungus) O
Installation
Drain pump ABDPG
E.S.P. control* O
Electric heater X
High ceiling operation* X
Auto Elevation Grille* X
Reliability
Hot start O
Self diagnosis O
Soft dry operation O
Convenience
Auto changeover** O**
Auto cleaning X
Auto operation(artificial intelligence)** O**
Auto Restart O
Child lock* O
Forced operation X
Group control* O
Sleep mode X
Timer(on/off) O
Timer(weekly)* O
Two thermistor control* O
Individual
control
Standard Wired remote controller O
Deluxe wired remote controller X
Simple wired remote controller X
Simple Wired remote controller(for hotel use) X
Wireless remote controller X
CAC network
function
General central controller (Non LGAP) X
Network Solution(LGAP) O
Dry contact PQDSA(1)/PQDSB(1) / PQDSBC
PI 485(for Indoor Unit) X
Special
function kit
Zone controller ABZCA
CTI(Communication transfer interface) X
Electronic thermostat X
Others
Remote temperature sensor PQRSTA0
Telecom shelter controller X
- 13 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
3. Ceiling & floor
Type Ceiling Suspended
Category Functions
AVNQ18GJLA0
AVNQ21GJLA0
AVNQ24GJLA0
AVNQ36GKLA0
AVNQ42GLLA0
AVNQ48GLLA0
AVNQ54GLLA0
Air flow
Air supply outlet 1
Airflow direction control (left & right) Manual
Airflow direction control (up & down) Auto
Auto swing (left & right) X
Auto swing (up & down) O
Airflow steps (fan/cool/heat) 3 / 4 / 3
Chaos wind(auto wind) O
Jet cool/heat O / X
Swirl wind X
Air purifying
Triple filter (Deodorizing) X
Plasma air purifier X
Allergy Safe filter X
Long-life prefilter (washable / anti-fungus) O
Installation
Drain pump X
E.S.P. control* X
Electric heater X
High ceiling operation* O
Auto Elevation Grille* X
Reliability
Hot start O
Self diagnosis O
Soft dry operation O
Convenience
Auto changeover** O**
Auto cleaning X
Auto operation(artificial intelligence)** O**
Auto Restart O
Child lock* O
Forced operation O
Group control* O
Sleep mode O
Timer(on/off) O
Timer(weekly)* O
Two thermistor control* O
Individual
control
Wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller X
Simple wired remote controller X
Simple Wired remote controller(for hotel use)
X
Wireless remote controller O
Network
function
General central controller (Non LGAP) X
Network Solution(LGAP) O
Dry contact
PQDSA(1)/PQDSB(1) / PQDSBC
PI 485(for Indoor Unit) X
Special
function kit
Zone controller X
CTI(Communication transfer interface) X
Electronic thermostat X
Others
Remote temperature sensor PQRSTA0
Telecom shelter controller X
Part 2 Functions & Controls
- 14 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 2 Functions & Controls
4. Outdoor
Category Functions 5 / 6 kW
7 kW ↑
Reliability
Defrost / Deicing X X
High pressure switch X X
Low pressure switch X X
Phase protection X X
Restart delay (3-minutes) O O
Self diagnosis O O
Soft start O O
Test function O X
Convenience Night Silent Operation O O
network
function
Network solution(LGAP) X O
Device 5 / 6 kW
7 kW ↑
Central
Controller
Simple Controller X PQCSB101S0
Function controller X PQCSB101S0 + PQCSC101S0
Function Scheduler X PQCSB101S0 + PQCSD130A0
AC Ez X PQCSZ250S0
AC Smart ll X PQCSW320A1E
Option Kit (SD card type) X PQCSE341A0 / PQCSE342A0
ACP(Advanced Control Platform) X PQCPA11A0E / PQCPB11A0E
AC Manager X PQCSS520A0E
PI485 X PMNFP14A0 / PMNFP14A1
DO(Digital Output) Kit X PQNFP00T0
BNU (Building
Network Unit)
LONWORKS Gateway X PQNFB16A1
BACnet Gateway X PQNFB17B0
Installation
Y branch X X
Header branch X X
Air Guide X X
ODU Dry Contact X X
Low Ambient Kit O (Logical operation) O (Logical operation)
- 15 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
2. Air flow
2.1 Auto swing (left & right)
RightLeft
110° ~ 120°
Open
Close
110° ~ 120°
Mode2
Mode3
Mode4
Mode5
Mode6
Mode7
Mode8
Mode9
OPEN
CLOSED
7~8°
110~120°
• By the horizontal airflow direction control key input, the left/right louver automatically operates with the auto swing or it
is fixed to the desired direction.
2.2 Auto swing (up & down)
• By the auto swing key input, the upper/lower vane automatically operates with the auto swing or it is fixed to the
desired direction.
2.3 Chaos swing (up/down)
• By the Chaos swing key input, the upper/lower vane automatically operates with the chaos swing or it is fixed to the
desired direction.
NOTE: Some Models are different by swing width and swing pattern.
Part 2 Functions & Controls
- 16 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 2 Functions & Controls
2.4 Air flow step
• Indoor fan motor control have 6 steps.
• Air volume is controlled "SH", "H", "Med", Low" by remote controller.
• "LL" step is selected automatically in Hot start operation.
2.5 Chaos wind (auto wind)
• When "Auto" step selected and then operated, the high, medium, or low speed of the airflow mode is operated for
2~15 sec. randomly by the Chaos Simulation
2.6 Jet Cool Mode Operation
• While in heating mode or Fuzzy operation, the Jet Cool key cannot be input.
When it is input while in the other mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operat-
ed.
• In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min. at cooling mode operation.
• In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C.
• When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.
• When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then operated
in order that the air outflow could reach further.
2.7 Swirl wind Swing
• It is the function for comfort cooling/heating operation.
• The diagonal two louvers are opened the more larger
than the other louvers. After one minute, it is opposite.
• Comparison of Air Flow Types
4-Open (conventional) Swirl Swing (New)
LL Very low, In heating mode
L Low
M Med
H High
SH Super high
Auto Chaos wind
Step Discription
Vane 4
Vane 2
Vane 1 Vane 3
- 17 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
3.1 PLASMA Air Purifying System
The PLASMA Air Purifying System not only removes microscopic contaminants and dust, but also removes house
mites, pollen, and pet fur to help prevent allergic diseases like asthma. This filter that can be used over and over again
by simply washing with water.
3. Air purifying
Ionizer
Photo-Catalyst Coated Mesh
Dust particles
Odour
Dust electrode discharge
Odour molecule
Generating plasma
+
+
+
+
Polluted Air
Purified fresh Air
+4.8KV discharge
+
Part 2 Functions & Controls
- 18 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 2 Functions & Controls
4.1 E.S.P. (External Static Pressure) Setting
4. Installation Functions
This is the function that decides the strength of the wind for each wind level and because this function is to make
the installation easier.
- If you set ESP incorrectly, the air conditioner may malfunction.
- This setting must be carried out by a certificated-technician.
TEMP
FAN
SPEED
OPER
MODE
When pressing the button and
button simultaneously for more than 3
seconds, the system will be entered into the
installer setting mode.
- After entering into the installer setting
mode, select the E.S.P code value by
pressing the button.
* E.S.P code value : 03
1
Select the desired air flow rate with
the button. Whenever pressing
the button, [Lo Med Hi] will be
indicated.
2
Select the desired air flow rate value with
the temperature up(s), down(t) button.
* E.S.P value range : 0~255
- E.S.P value will be indicated at the upper
right section of the display window.
3
When pressing the button, currently
established E.S.P value will be set up.
4
When pressing the button and
button simultaneously for more than 3
seconds after the setting has been
completed, the setting mode will be released.
- If there isn’t any button input for more than
25 seconds, the installer setting mode will
also be released.
5
OPER
MODE
OPER
MODE
FAN
SPEED
FAN
SPEED
OPER
MODE
- Precaution shall be taken not to alter the E.S.P value corresponded to each air flow section.
- E.S.P value can be varied according to the products.
- In the case of going to the next air flow rate stage by pressing the fan-speed button during the setup of the E.S.P
value, the E.S.P value of previous air flow rate will be maintained by remembering the E.S.P value prior to the
shift.
- 19 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
E.S.P. setting value (reference)
[ Notes ]
1. To get the desired Airflow & E.S.P. combination from the table set the matching value from the table. Value other than
that in table will not give the combinations of airflow & E.S.P. which are mentioned in the table.
2. Table data is based at 230V. According to the fluctuation of voltage, air flow rate varies.
Table 1
Part 2 Functions & Controls
Setting Value
Static Pressure[mmAq(Pa)]
2.5(25) 4(39) 6(59) 8(78)
100 12.8 - - -
105 13.9 - - -
110 15.2 12.7 - -
115 16.5 14.0 - -
120 17.8 15.3 12.7 -
125 - 16.5 14.0 -
130 - 17.8 15.3 12.6
135 - - 16.5 13.5
140 - - 17.5 14.5
145 - - - 16.5
(Unit: CMM)
(Unit: CMM)
Setting Value
Static Pressure[mmAq(Pa)]
4(49) 6(59) 8(78) 10(98)
100 20.8 - - -
105 23.2 19.5 - -
110 26.0 21.5 - -
115 - 23.5 19.1 -
120 - 26.3 21.6 -
125 - - 24.0 19.9
130 - - 27.0 22.7
135 - - - 25.9
(Unit: CMM)
Models : ABNQ18GHLA0, ABNQ21GHLA0
Models :
ABNQ24GGLA0
Models :
ABNQ36GGLA0
Setting Value
Static Pressure[mmAq(Pa)]
6(59) 8(78) 10(98) 12(118) 14(137)
80 14.8 - - - -
90 19.0 14.4 - - -
100 23.3 19.7 13.9 - -
110 26.9 24.3 19.8 14.1 -
120 31.2 28.2 25.2 20.1 14.4
130 34.9 32.4 29.5 25.4 20.5
- 20 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 2 Functions & Controls
Setting Value
Static Pressure[mmAq(Pa)]
6(59) 8(78) 10(98) 12(118)
85 31.5 - - -
90 36.3 29.8 - -
95 41.3 34.5 28.4 -
100 45.4 39.7 33.5 27.3
105 - 44.1 38.6 33.1
110 - - 44.2 38.9
115 - - - 44.7
(Unit: CMM)
Setting Value
Static Pressure[mmAq(Pa)]
6(59) 8(78) 10(98) 12(118)
85 31.5 - - -
90 36.3 29.8 - -
95 41.3 34.5 28.4 -
100 45.4 39.7 33.5 27.3
105 - 44.1 38.6 33.1
110 - - 44.2 38.9
115 - - - 44.7
(Unit: CMM)
Setting Value
Static Pressure[mmAq(Pa)]
6(59) 8(78) 10(98) 12(118) 14(137)
95 41.3 - - - -
100 45.4 39.7 - - -
105 49.5 44.1 38.6 - -
110 - 48.5 44.2 38.9 -
115 - - 49.8 44.7 42.2
120 - - - 50.5 48.1
(Unit: CMM)
Models :
ABNQ42GRLA0
Models :
ABNQ48GRLA0
Models :
ABNQ54GRLA0
※ ABNQ42GRLA0 / ABNQ48GRLA0 As far as possible do not set ESP 82,83
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

LG AUUQ18GH1.AWGBBRZ Owner's manual