For ADA compliance (Americans with Disabilities Act) consult ADAAG or your state regulations
for proper product choice and mounting heights. ADAAG does permit a fixed shower head
mounted 48” above the floorin unmonitored facilities where vandalism may be a problem.
Recommended head heights
Men ____________________________ 6’0”
Boys, Senior High _________________ 5’10”
Boys, Junior High _________________ 5’7”
Boys, Elementary _________________ 5’4”
Women _________________________ 5’8”
Girls, Senior High _________________ 5’8”
Girls, Junior High _________________ 5’5”
Girls, Elementary __________________ 4’2”
INSTALLATION:
1. With special screwdriver provided
remove screw located on shield above
valve, remove head bracket with hex
socket key, remove large locking nut,
remove valve handle with hex socket
key, remove dome and nameplate
with locking ring. Remove unit cover.
CAUTION: Do not misplace vandal-
proof screws after removing from unit
cover.
2. Mount valve and piping assembly to
wall with screws and anchors pro-
vided. Connect supply piping.
3. Replace unit cover and reassemble in
reverse order.
4. Install shower head.
1-901Series
INSTALLATION INSTRUCTIONS
Product meets ANSI A112.18.1M
Flow rate: 2.5 gpm (9.5 L/min)
Drilling pattern for valve
and piping assembly
Hydapipe
®
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184
Phone: (800) 796-6667
Fax: (800) 961-9621
Website: symmons.com
Email: gethelp@s ymmo ns.c om
Copyright © 2017 Symmons Industries, Inc.
ZV-331 REV A 090117
T-17
HP-7A
HP-7A
HPN-15
HPN-28
T-11
T-12A
TA-9
(INCLUDES T-11)
T-16
TA-10
T-8
T-7
T-1
LM-26 SW
T-2
T-3
T-5
T-6
RC-14X
HPN-7A
T-20PL
SC-15A
HPN-10
HP-7A
T-34
HPN-14
HPN-11
HP-14B
HP-14A
HP-14A
HP-14A
HP-14A
HP-7A
HPN-9
HPN-6
HP-7A
SC-15A
HPN-13
HPN-5
4-282M
300A
TA-4
L-23
HP-14B
.
INDIVIDUAL PARTS INDIVIDUAL PARTS COMPOSITE PARTS
HP-7A Screw
HP-14A Screw
HP-14B Star plastic anchors
HPN-5 Top cap
HPN-6 Soap dish
HPN-7 Nameplate
HPN-9 Shower head bracket
HPN-10 Dome cover
HPN-11 Head mounting bracket
HPN-13 Mounting bracket nut
HPN-14 Head bracket stud
HPN-15 Pipe and shield bracket
HPN-28 Locking nut
L-23 O-ring
LM-26 SW Service stop complete
RC-14X Handle
SC-15A Set screw
T-1 Hot renewable seat
T-2 Cold seat o-ring
T-3 Cold renewable seat
T-5 Hot washer screw
T-6 Hot washer
T-7 Cold washer retainer
T-8 Cold washer
TA-10 Flow control spindle
T-11 Cap gasket
T-12A Cap assembly
T-16 Packing, o-ring and washer
T-17 Packing nut
T-20PL Dome lock nut
T-34 Limit stop with o-ring
300A Set screw
4-282M Fre-Flo shower head
TA-4 Hot seat (T-1)
Cold seat (T-3)
Cold seat O-ring (T-2)
TA-9 Hot washer screw (T-5)
Hot washer (T-6),
Cold water retainer (T-7)
Cold washer (T-8),
Cap gasket (T-11)
TA-10 Spindle assembly
Tools required for installation:
Slotted screwdriver, Phillips screwdriver,
soldering equipment, adjustable wrench,
channel lock pliers, hex socket keys (1/8”
and 3/32”), electric drill with 1/4” drill bit,
HY-50 screwdriver (provided)
CAUTION: Do not misplace vandal-proof
screws (HP-7A) after removing from unit
cover. Screws will be required to reinstall
unit cover to piping assembly.
  • Page 1 1
  • Page 2 2

Symmons Industries 1-901S Installation guide

Category
Flat panel accessories
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI