Hytronik HC008S User manual

  • Hello! I'm a chat assistant and I've reviewed the datasheet for the HYTRONIK Daylight Sensors DS05, DS06 and DS07. This document includes technical specifications such as input voltages, output loading, and information on Photocell Advance technology, as well as details on features like Pro-active Lux Switching and DALI broadcast output. I'm ready to answer any questions about these daylight sensors.
  • What is the input voltage for these Daylight Sensors?
    What is the maximum output loading for DS05 and DS06?
    What is the output of DS07?
    What is the warming-up period for these sensors?
    Which handset is used for sensor settings?
Daylight Sensors
DS05
DS06
DS07
HRC-11
Photocell
Advance™
Photocell
Advance™
Photocell
Advance™
On/off
400VA/800W
On/off
80mA power
supply (PSU)
220-240Vac
50/60Hz
220-240Vac
50/60Hzt
HRC-11
HRC-11
Daylight harvest
400W/800W
220-240Vac
50/60Hz
Input Output Pro-active Lux
Switching
Daylight Sensor Remote
Controller Page
DIP-Switch
Settings
Overview: Daylight Sensors
299
299
299
297
DS07
• Daylight sensor: Photocell Advance™ (*See pg. 14-17)
• Pro-active Lux Switching technology (*See pg. 16)
• Switch-Dim (PUSH) terminal
• Sensor settings via handset HRC-11
• Optional accessory: end-caps on both end
• Input: 220-240VAC, 50/60Hz
• Output (Max Loading): 80mA
• Warming-up period: 20s
• Ta: -20°C ~ +60°C; Tc: +80°C
• DALI broadcast output
• Daylight harvest
• Daylight sensor: Photocell Advance™ (*See pg. 14-17)
• Pro-active Lux Switching technology (*See pg. 16)
• Switch-Dim (PUSH) terminal
• Sensor settings via handset HRC-11
• Optional accessory: end-caps on both end
• Input: 220-240VAC, 50/60Hz
• Output (Max Loading):
400VA capacitive / 800W resistive
• Warming-up period: 20s
• Ta: -20°C ~ +60°C; Tc: +80°C
• 1-10V control with relay output
• Daylight harvest
DS05
DS02
•On/Off control with relay output
• Daylight sensor: Photocell Advance™ (*See pg. 14-17)
• Pro-active Lux Switching technology (*See pg. 16)
• Daylight settings via DIP switches handset HRC-11
•Input: 220-240VAC, 50/60Hz
• Output (Max Loading):
400VA capacitive 800W resistive
•Warming-up period: 20s
• Ta: -20°C ~ +60°C; Tc: +80°C
DS06
Full Product Specications - - - DS05 & DS06 & DS07
HRC-11
HRC-11
HRC-11
Suitable for
Bulkhead Tri-proof
Linear Pendant
Suitable for
Bulkhead Tri-proof
Linear Pendant
Suitable for
Bulkhead Tri-proof
298
/