American Standard 2071, 2071S User manual

  • Hello! I am an AI chatbot trained to assist you with the American Standard 2071 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Plumbers' Putty or CaulkingAdjustable Wrench Phillips ScrewdriverChannel Locks
TOOLS REQUIRED
MONOBLOCK
LAVATORY FAUCET
WITH CROSS HANDLE
Installation
Instructions
M968290A
Certified to comply with ANSI A112.18.1M
2071
2071S
Thank you for selecting American-Standard...the benchmark of fine
quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these
instructions carefully before you begin.
by
COLLECTION
THE
BOSS
GROOVE IN
FAUCET BASE
LAVATORY SINK
OR MOUNTING
SURFACE
3
2
6
7
1
5
6
4
1
Insert LIFT ROD (7).
From below, install MOUNTING GASKET with
RETAINING WASHER (5) and Nut (6) onto
STUD (4). Pull Faucet to front of sink, so STUD
(4) rests against sink hole. Before final tightening,
align Faucet and ESCUTCHEON (1) so they are
centered on mounting surface. Tighten NUT (6)
to secure Faucet
From below, install MOUNTING GASKET with
RETAINING WASHER (5) and Nut (6) onto
STUD (4). Pull Faucet to front of sink, so STUD
(4) rests against sink hole. Before final tightening,
align Faucet and ESCUTCHEON (1) so they are
centered on mounting surface. Tighten NUT (6)
to secure Faucet
For single hole installation use ESCUTCHEON
RING (2). Install SEAL WASHER (6) into groove
in ESCUTCHEON RING (2) base and place over
over mounting hole in lavatory sink or mounting
surface.
Insert LIFT ROD (7).
Feed FLEXIBLE FAUCET HOSES (3) and MOUNTING
STUD (4) through hole in ESCUTCHEON RING (2).
Seat ESCUTCHEON RING (2) boss into groove in
Faucet base.
Feed FLEXIBLE FAUCET HOSES (3) and MOUNTING STUD (4) through
hole in ESCUTCHEON PLATE (1). Seat ESCUTCHEON PLATE (1) boss
into groove in Faucet base.
INSTALL FAUCET
Turn off water at
main supply.
CAUTION
INSTALLATION OPTIONS; Faucet may be installed with ESCUTCHEON
PLATE (1) or for center hole only with ESCUTCHEON RING (2).
INSTALLATION with ESCUTCHEON PLATE (1)
INSTALLATION with ESCUTCHEON RING (2)
BOSS
GROOVE IN
ESCUTCHEON
RING BASE
Remove as much surface dirt and film using clear
water and soft cotton cloth (as described above).
Once clean, rinse faucet again with clear water to
thoroughly remove cleaner or polish and blot dry with
a soft cotton cloth.
To keep your new faucet looking new, please follow
these simple care instructions:
DO: Simply rinse the faucet clean with clear water.
Dry the faucet with a soft cotton cloth.
Do not use any abrasive cleaners, cloths, or
paper towels.
Do not use any cleaning agents containing
acids, polish abrasives, or harsh cleaners or
soaps.
Regular and routine cleaning will reduce the need for
heavy cleaning and polishing. If heavy cleaning is
CARE INSTRUCTIONS:
Failure to follow these care instructions may
damage the Faucet's finish.
DO NOT:
Use any of the following to remove tough surface
film and build-up:
Mild liquid detergents
Clear ammonia free liquid glass cleaners
Non-acidic, non-abrasive gentle liquid or fully
dissolved powder cleansers mixed according to
manufacturers directions.
Non-abrasive liquid polishers
No sealant is required unless mounting surface is uneven for 3-hole
(4" centers) installation with ESCUTCHEON PLATE (1). Place ESCUTCHEON
PLATE (1) over mounting holes on lavatory sink or mounting surface.
M968290A
3
WATER SUPPLY CONNECTIONS
Note:
FLEXIBLE HOSES (1, 2) on FAUCET (3) are (17-1/2") in
length from base of faucet. If longer supply length is required
installer must purchase adapters and additional supplies to
complete connections.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking .
Connection on FLEXIBLE HOSES (1, 2) are 3/8" compression.
Connect LEFT SUPPLY (1) to Hot shut off valve and RIGHT
SUPPLY (2) to Cold shut off valve.
Use adjustable wrenches to tighten connections. Do not
over tighten.
1
3
2
COLD
HOT
SHUT OFF
VALVE
(17-1/2")
3/8" compression
1
2
A
3
4
5
10
11
12
8
G
F
D
E
6
7
F
C
9
1-1/4"
FIGURE-3A:
O-RING
9
INSTALL POP-UP DRAIN
2
Push Tail piece (11) down into Trap (C) (threaded end up).
Assemble Pivot Rod (9) as shown in Figure-3A. Notice
the position of the Concave Washer (G).
Insert Pivot Rod (9) into Drain Body (10) and tighten
Pivot Nut (F).
Thread Locknut (5), Washer (4) and Gasket (3) (Bevel side
up) onto Drain Body (10).
Apply a bead of Putty (D) to underside of Flange (2).
Remove one end of Clip (8) from Pivot Rod (9) by squeezing
ends together while sliding.
Insert Pivot Rod (9) or (9A) into second or third hole in Extension
Rod (7) and reassemble Clip (8).
Adjust stopper height by repositioning Extension Rod (7) and
tightening Thumbscrew (6).
Feed Drain Body (10) up through Sink (A) and thread the
Flange (2) or (2A) fully onto Drain Body (10).
Tighten Locknut (5) firmly, keeping the pivot rod hole pointed
towards the back of the sink.
Drop Stopper (1) into Drain Body (10).
Position Extension Rod (7) onto Pop-Up Rod (E) and tighten
Thumbscrew (6).
Push TAILPIECE INSERT (12) into TAILPIECE (11) and push
TAILPIECE up and thread tightly into DRAIN BODY (10).
7
M968290A
ADJUST HOT LIMIT STOP
By restricting HANDLE rotation and limiting the amount of hot water
allowed to mix with the cold, the HOT LIMIT SAFETY STOP (5) reduces
risk of accidental scalding. To set the maximum hot water temperature
of your faucet, all you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP (5).
1
5
1
3
1
1
9
7
5
3
1
0
5
Remove INDEX BUTTON (1), HANDLE SCREW (2) and pull off HANDLE (3).
Replace HANDLE (3), HANDLE SCREW (2) and INDEX BUTTON (1).
Turn CARTRIDGE STEM (4) to the OFF position (coldest setting) before
making adjustment to HOT LIMIT STOP (5). Use a flat blade screwdriver
to pry free the HOT LIMIT SAFETY STOP (5). Pull upward and rotate
counterclockwise one number to limit hot water temperature. Use
ARROW (6) on CARTRIDGE (7) and NUMBERS (8) on HOT LIMIT STOP (5)
for indication.
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
1
5
1
3
1
1
9
7
5
3
1
1
5
1
3
1
1
9
7
5
3
1
1
1
2
5
4
5
8
5
7
6
6
4
1
2
3
4
5
6
HOT
4a
CHECK DRAIN CONNECTIONS
Operate LIFT ROD (4) and fill lavatory with water. Check that
DRAIN STOPPER (5) makes a good seal and retains water in
lavatory. If necessary adjust stopper height by repositioning
LIFT ROD (4) and tightening Thumbscrew (6).
Release DRAIN STOPPER (5) and check all drain connections
and "P" trap for leaks. Tighten if necessary.
COLD
4
TEST INSTALLED FAUCET
AND CHECK FOR LEAKS
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
"P" TRAP
FLAT BLADE
SCREWDRIVER
1
5
1
3
1
1
9
7
5
3
1
3
5
072574-0070A
EXTENSION ROD
066116-YYY0A
DRAIN STOPPER
GASKET
WASHER
LOCKNUT
M961711-0070A
TAILPIECE INSERT
FLANGE
070847-0070A
CLIP
066118-0070A
PIVOT ROD
953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070532-0040A
TAILPIECE
066117-YYY0A
FLANGE KIT
M962237-0070A
INDEX BUTTON
A918657-0070A
HANDLE SCREW
M962236-YYY0A
HANDLE
918633-0070A
CARTRIDGE SCREWS
A923611-0070A
HOT LIMIT STOP
A954400-0070A
CARTRIDGE KIT
M962239-YYY0A
ESCUTCHEON KIT
(SINGLE HOLE)
M962238-YYY0A
ESCUTCHEON KIT
(THREE HOLE)
051049-0070A
MOUNTING KIT
M968290A
Replace the "YYY" with
appropriate finish code
by
COLLECTION
THE
CHROME
SATIN
002
295
3
066070-YYY0A
AERATOR
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2003
2071
2071S
MONOBLOCK
LAVATORY FAUCET
WITH CROSS HANDLE
MODEL NUMBER
M962242-YYY0A
KNOB & ROD
M914423-YYY0A
METAL RING
A912706-0070A