Greenheck 474637 ESD-635D, Flange/Sleeve is a versatile and durable product designed to withstand wind loads of up to 150 PSF. It can be installed in various building conditions, including concrete/masonry, steel stud, structural steel, or wood-framed structures. The ESD-635D can be used for single or multiple sections, with a maximum single section rough opening size of 72.50" W x 144.50" H. Its flange/sleeve design allows for easy installation and provides a secure fit. It is Miami-Dade Qualified and Florida Product Approved, ensuring compliance with local building codes.

Greenheck 474637 ESD-635D, Flange/Sleeve is a versatile and durable product designed to withstand wind loads of up to 150 PSF. It can be installed in various building conditions, including concrete/masonry, steel stud, structural steel, or wood-framed structures. The ESD-635D can be used for single or multiple sections, with a maximum single section rough opening size of 72.50" W x 144.50" H. Its flange/sleeve design allows for easy installation and provides a secure fit. It is Miami-Dade Qualified and Florida Product Approved, ensuring compliance with local building codes.

®
ESD-635D Flange/Sleeve Installation 1
®
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety information. Failure
to comply with these instructions will result in voiding of the product warranty and may result in personal injury
and/or property damage.
Document 474637
ESD-635D
Flange/Sleeve Installation
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-1919.04
Maximum Wind-load: 150 PSF
ESD-635D Flange/Sleeve Installation2
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-1919.04
Maximum Wind-load: 150 PSF
Maximum Size and Installation Information
Model ESD-635D is a Miami-Dade Qualified and Florida Product Approved louver and must be installed in accordance with
the installation instructions shown herein. Model ESD-635D is qualified for installation within concrete/masonry, steel stud,
structural steel or wood framed building conditions. Model ESD-635D is structurally calculated to withstand positive and
negative wind-loads up to 150 PSF. The maximum single section rough opening width is 72.50 in. The maximum single section
rough opening height is 144.50 in. While the maximum rough opening height is limited to 144.50 in., the rough opening width is
limited to 1,000 in. as multiple sections may be installed side by side in accordance with installation instructions.
Minimum Rough
Opening Size
12 in. W x 12 in. H
Maximum Single Section
Rough Opening Size
72.50 in. W x 144.50 in. H
Building Condition/Substrate Limitations
• All wood substrate shall be G= 0.55 density or better
• All metal stud substrate should be min. 16 Ga. FY= 50 KSI
• All structural steel substrate shall be min. 0.25 in. thick FY= 36 KSI
• All concrete substrate shall be min. 3000 PSI
• Concrete masonry shall be ASTM C90, Type II, 2000 PSI, grout-filled
ESD-635D Flange/Sleeve Installation 3
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-1919.04
Maximum Wind-load: 150 PSF
Single Section
ESD-635D Flange/Sleeve Installation4
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-1919.04
Maximum Wind-load: 150 PSF
Multiple Sections
Height ≤ 96 ½
ESD-635D Flange/Sleeve Installation 5
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-1919.04
Maximum Wind-load: 150 PSF
Multiple Sections
Height > 96 ½ ≤ 144 ½
ESD-635D Flange/Sleeve Installation6
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-1919.04
Maximum Wind-load: 150 PSF
Single Section
Structure Depth
• Min. structure depth 4 in.
• Max. structure depth 10.5 in. (12 in. sleeve)
• Max. structure depth 14.5 in. (16 in. sleeve)
ESD-635D Flange/Sleeve Installation 7
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-1919.04
Maximum Wind-load: 150 PSF
Multiple Sections
Height ≤ 96 ½
Structure Depth
• Min. structure depth 4 in.
• Max. structure depth 11.5 in.
474637 • ESD-635D Flange/Sleeve Installation, Rev. 2, 12-18 Copyright 2018 © Greenheck Fan Corporation8
As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications
without notice.
Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature
section of the website at Greenheck.com/Resources/Library/Literature.
®
Phone: 715.359.6171 • Fax: 715.355.2399 • Parts: 800.355.5354 • E-mail: [email protected] • Website: www.greenheck.com
Our Commitment
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-1919.04
Maximum Wind-load: 150 PSF
Multiple Sections
Height > 96 ½ ≤ 144 ½
Structure Depth
• Min. structure depth 4 in.
• Max. structure depth 13.25 in.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Greenheck 474637 ESD-635D, Flange/Sleeve Operating instructions

Type
Operating instructions

Greenheck 474637 ESD-635D, Flange/Sleeve is a versatile and durable product designed to withstand wind loads of up to 150 PSF. It can be installed in various building conditions, including concrete/masonry, steel stud, structural steel, or wood-framed structures. The ESD-635D can be used for single or multiple sections, with a maximum single section rough opening size of 72.50" W x 144.50" H. Its flange/sleeve design allows for easy installation and provides a secure fit. It is Miami-Dade Qualified and Florida Product Approved, ensuring compliance with local building codes.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI