  • Hello! I am an AI chatbot trained to assist you with the Greenheck 474641 EHH-601D, Flange/Sleeve Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
®
EHH-601D Flange/Sleeve Installation 1
®
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety information. Failure
to comply with these instructions will result in voiding of the product warranty and may result in personal injury
and/or property damage.
Document 474641
EHH-601D
Flange/Sleeve Installation
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-0919.05
Maximum Wind-load: 150 PSF
EHH-601D Flange/Sleeve Installation2
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-0919.05
Maximum Wind-load: 150 PSF
Maximum Size and Installation Information
Model EHH-601D is a Miami-Dade Qualified and Florida Product Approved louver and must be installed in accordance with
the installation instructions shown herein. Model EHH-601D is qualified for installation within concrete/masonry, steel stud,
structural steel or wood framed building conditions. Model EHH-601D is structurally calculated to withstand positive and
negative wind-loads up to 150 PSF. The maximum single section rough opening width is 72.50 in. The maximum single section
rough opening height is 144.50 in. While the maximum rough opening height is limited to 144.50 in., the rough opening width is
limited to 1,000 in. as multiple sections may be installed side by side in accordance with installation instructions.
Minimum Rough
Opening Size
12 in. W x 7 in. H
Maximum Single Section
Rough Opening Size
72.50 in. W x 144.50 in. H
Building Condition/Substrate Limitations
• All wood substrate shall be G= 0.55 density or better
• All metal stud substrate should be min. 16 Ga. FY= 50 KSI
• All structural steel substrate shall be min. 0.25 in. thick FY= 36 KSI
• All concrete substrate shall be min. 3000 PSI
• Concrete masonry shall be ASTM C90, Type II, 2000 PSI, grout-filled
EHH-601D Flange/Sleeve Installation 3
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-0919.05
Maximum Wind-load: 150 PSF
Single Section
EHH-601D Flange/Sleeve Installation4
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-0919.05
Maximum Wind-load: 150 PSF
Multiple Sections
Height ≤ 96 ½
EHH-601D Flange/Sleeve Installation 5
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-0919.05
Maximum Wind-load: 150 PSF
Multiple Sections
Height > 96 ½ ≤ 144 ½
EHH-601D Flange/Sleeve Installation6
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-0919.05
Maximum Wind-load: 150 PSF
Single Section
Structure Depth
• Min. structure depth 4 in.
• Max. structure depth 10.5 in. (12 in. sleeve)
• Max. structure depth 14.5 in. (16 in. sleeve)
EHH-601D Flange/Sleeve Installation 7
®
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-0919.05
Maximum Wind-load: 150 PSF
Multiple Sections
Height ≤ 96 ½
Structure Depth
• Min. structure depth 4 in.
• Max. structure depth 11.5 in.
474641 • EHH-601D Flange/Sleeve Installation, Rev. 2, 12-18 Copyright 2018 © Greenheck Fan Corporation8
As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications
without notice.
Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature
section of the website at Greenheck.com/Resources/Library/Literature.
®
Phone: 715.359.6171 • Fax: 715.355.2399 • Parts: 800.355.5354 • E-mail: [email protected] • Website: www.greenheck.com
Our Commitment
Florida Product Approval No: FL10088
Miami-Dade NOA No.: 17-0919.05
Maximum Wind-load: 150 PSF
Multiple Sections
Height > 96 ½ ≤ 144 ½
Structure Depth
• Min. structure depth 4 in.
• Max. structure depth 13.25 in.
/