SICK Safety and Warning Instruction for VLR Products Operating instructions

Type
Operating instructions
Safety and Warning Instruction Sheet For VLR Products
Consult www.sick.com for more information
*** Read this instruction sheet before attempting to use the product ***
Thank you for purchasing a Sick VLR product. To properly use the product and take full
advantage of the functionality, read the instruction sheet before using the product. After
reading the instruction sheet, store it in a safe and readily accessible location.
Safety Precautions
Information in this instruction sheet marked with a “WARNING” “CAUTION” or
IMPORTANT” is provided to help prevent injury, electrical shock and other accidents.
Be sure to follow the information provided.
WARNING
1. Do not disassemble or modify the product.There is a danger of fire or electrical shock.
2. Connect the illumination cable directly to the illumination power supply.Using power
strips or otherwise overloading a power outlet into which the illumination power
supply is connected may cause fires. When it is necessary to use an extension cable,
use the optional extension cable.
3. The illuminator device becomes very hot depending on the mounting, the
environmental temperature and the mode of operation. Do not touch with your hands
during operation.
4. Do not touch the LED lighting or cable with wet hands, there is a danger of electrical
shock.
5. In the event of a malfunction, such as the LED lighting emitting smoke, overheating,
giving off a strange odour or making strange noises, stop operating immediately. Turn
OFF the power supply and unplug the cable from the power outlet.
6. Do not look directly into the LED light. LEDs emit incoherent light from a larger
emitting area compared to a semiconductor laser, so for the same output power the
power density is lower. However, avoid looking directly into any bright light or looking
directly at the light for an extended period while the strobe is flashing. Failure to do so
may adversely affect the eyes. Using procedures not included this manual may result
in harmful exposure to LED irradiation.
CAUTION
1. When using illuminator devices with a power consumption of 10W or more without a
cooling fan, use the ON/OFF external control or other functions to suppress warming
of the illuminator devices and avoid keeping the illuminator devices continuously lit.
2. If it is necessary to use an extension cable, use a cable with a max length of 5 m. If a
cable longer than 5 m is used, the DC resistance of the cable will reduce the voltage
applied at both ends of the LED light. Even when using 100% modulated light, the
rated voltage level will not be achieved and the light intensity will be reduced. The
total cable length is limited to max. 10 m
IMPORTANT
1. When plugging in or unplugging the power cable to the light, be sure to turn off the
power supply first. Circuit damage, small sparks, fire and shocks may result if the
power cable is plugged in or unplugged while the power supply is ON.
2. Take measures to suppress the heat emitted by the LED lighting. The LED life span
is shortened when used in high-temperature, high humidity environments. When the
LED is left ON continuously, stable performance characteristics and a long life span
can be achieved by setting the modulated light volume of the power supply to 50% or
less. Heat generation can be controlled and stable operation achieved by turning ON
the LED only while images are being taken (intermittent illumination).
3. Note the following points when using a white LED lighting with colour image
processing equipment. When the LED lighting is left ON continuously, the
temperature of the spotlight will rise, causing changes in brightness and hues. Re-
adjust the camera’s white balance about 60 minutes after turning ON the power of the
LED lighting. When using the LED lighting for intermittent illumination, it can be used
as soon as the power is turned ON.
4. Static electricity built up in the human body may be released when a person comes
into contact with parts of the LED, such as the LED mounting plate, possibly
damaging the illuminator device. Do not allow objects charges with static electricity
near the illuminator device.
5. VLR light products are designed and built for use as illumination in image processing
applications. The following uses are not covered under warranty: Use under
conditions or in an environment not described in this instruction sheet. Use in nuclear
power control, railways, aircraft, vehicles, combustion equipment, medical
applications, amusement devices or safety devices. Use in which there is a large and
foreseeable risk to life and property, particularly applications demanding a high level
of safety.
6. VLR Trigger unit is only intended for use with VLR lights. If used with other light types
the Trigger unit may not work properly or and missuse can lead to broken VLR
Trigger unit.
7. VLR Trigger unit is not short circuit protected.
8. Reverse polarity protection is only valid for connected VLR lights, not for other
electrical loads.
Wiring
This section describes the wiring possiblities with VLR products
VLR Trigger unit
Connecting VLR Trigger unit to IVC-2D
1. Connect IVC-2D power connector via connector [1] and
VLR light via connector [2]
2. Connect an unpowered 24 VDC power supply to connector [3] before
switching on the power supply
Connecting VLR Trigger unit to Inspector
1. Use T-adapter 6034950 and screw it into Inspector power connector
2. Connect the T-adapter (6034950) via cable 6026625 (1m/8-pin/male/female)
to [3] and VLR-light via connector to [2]. (Connector [1] is not used)
3. Connect an unpowered 24 VDC power supply via cable
(6034604/2m/12pol/female) to T-adapter (12-pol) before switching on the
power supply
Pin configuration of VLR lights with M12 4-pin male connector
Connection of VLR-XXPL1011
VLR-XXPL1011P01 is a kit and contains the necessary parts for proper connection. Use
only these parts as a complete kit. Use connection cable [b] when connecting the spot
light [a] to the power supply [c]. Switch on the power supply.
SafetyStandards
ISM High Frequency statement
ISM high frequency classification EN 55011: Group 1, class A. Warning:
Devices in class A are designed for operation in an industrial environment.
8013193 AE
_
U668
Safety and Warning Instruction Sheet For VLR Products
Consult www.sick.com for more information
VLR-66RL0111
VLR-10RK0211
VLR-10BR1111
VLR-47BR1111
VLR-52BR1111
VLR-66BR1111
VLR-66RA1211
VLR-66CA0311
VLR-66FD1511
VLR-47RL0411
VLR-66RL0411
VLR-66PL1011P01
VLR-52PL1011P01
VLR-47PL1011P01
VLR-10PL1011P01
VLR-66RA2011
VLR-66RD1311
VLR-10RD1311
VLR-Trigger unit
SICK part number
6035957 6035958 6035959 6035960 6035961 6035962 6035963 6035964 6035965 6037792 6037793 6037794 6037796 6037797 6037795 6037798 6037799 6037800 6037290
Supply voltage
24 VDC
24 VDC +/- 10%
24 VDC +/- 20%
Power consumption (mA) < 125 < 250 < 363 < 363 < 363 < 363 < 525 < 525 < 200 < 720 < 400 < 335 < 335 < 335 < 335 < 900 < 250 < 400
Max output current A 1,5
Connector
M12 4 pin
Kit*
Operating temperature
0 - 40° C
0 - 50° C
Degradation period of LED's*
> 35 000 h**
Strobing mode
Continous mode
ROHS
OK
CE
OK
IP protection class
IP20
IP67
VDE protection class
III
Laser protection class LED
LED Danger classification:
Risk Group 1 (low risk)
according to IEC 62471:2006
2
Dimension (outer/innerø) or
(lengthxwidth) mm
50/28 ø 70x70 109x28 109x28 109x28 109x28 134/96 ø 73x70 143x143 90/50 ø 90/50 ø 100x58 100x58 100x58 100x58 208/172 ø 138x138 138x138 140x50x25
Colour, wavelength nm
660
525
470
White
Family of light
Bar light
Ring light
Low angle ring light
On axis light
Flat dome light
Spot light
Dark field light
Recommended light working distance (mm) 40-100 100-200 N/A N/A N/A N/A 5-50 5-80 10-50 50-150 50-150 2 000 2 000 2 000 2 000 5-75 N/A N/A N/A
Field of view at recommended working dist. (mm) 60 ø 70 ø N/A N/A N/A N/A 80 ø 73x70 100x100 80 ø 80 ø 300 ø 300 ø 300 ø 300 ø 120 ø N/A N/A N/A
Weight (gram)
40 130 115 115 115 115 255 580 360 145 145 350 350 350 350 300 210 210 100
Operating temp. min/max
0° C .. +40° C
0° C .. +50° C
Storage temp. Min/max
-20° C .. +60° C
-20° C .. +70° C
0° C .. +70° C
Humidity
85% relative
VLR illuminations
* Drop in intensity to 50%
** In triggered mode at pulse interval ratio < 20%.
  • Page 1 1