ML Accessories SHE1GEMS User manual

Type
User manual
INSTALLATION & MAINTENANCE MANUAL
SHE1BEMS / SHE1GEMS
SHE2BEMS / SHE2GEMS
These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
SHE1BEMS / SHE1GEMS / SHE2BEMS / SHE2GEMS
GENERAL INSTRUCTIONS
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse, or circuit breaker
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
This product is Class I and must be earthed
This product is IP65 rated
SAFETY
INSTALLATION
Note - Microwave sensors may not be suitable for all installations, for example enclosed spaces, as they are able to
detect movement through non-metallic surfaces like plasterboard and thin doors.
Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP rated
junction boxes should be used where required
Remove the diffuser by unscrewing the four hex screws at the front of the diffuser
Using the baseplate as a template, mark the location for, and drill the fixing holes ensuring not to infringe with any
gas/water pipes or electrical cables
Feed the mains cable through the rubber grommet to retain IP rating, and secure the baseplate to the surface
Ensuring correct polarity is observed, carefully wire as shown in Fig. 1
Fig. 1
Fig. 2
Ensure the earth lead on the LED plate is secured correctly to the earth lead on the body of the fitting
Fix the LED tray to the body
Choose the required colour temperature by means of the three-position switch (see Fig. 2)
• Please see DIP switch layout to set up the sensor
• Replace the diffuser ensuring seal is in place
• Switch on and check for correct operation, ensuring the green indicator LED is illuminated
We recommend, on commissioning the installation, a minimum charge period of 24 hours before carrying
out an emergency duration test
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
SHE1BEMS / SHE1GEMS / SHE2BEMS / SHE2GEMS
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of
the circuit cable, fuse, or circuit breaker
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
This product is Class I and must be earthed
This product is IP65 rated
INSTALLATION
Note - Microwave sensors may not be suitable for all installations, for example enclosed spaces, as they are
able to detect movement through non-metallic surfaces like plasterboard and thin doors.
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
Remove the diffuser by unscrewing the four hex screws at the front of the diffuser
Using the baseplate as a template, mark the location for, and drill the fixing holes ensuring not to
infringe with any gas/water pipes or electrical cables
Feed the mains cable through the rubber grommet to retain IP rating, and secure the baseplate to the
surface
Ensuring correct polarity is observed, carefully wire as shown in Fig. 1
Fig. 1
Ensure the earth lead on the LED plate is secured correctly to the earth lead on the body of the fitting
Fix the LED tray to the body
Choose the required colour temperature by means of the three-position switch (see Fig. 2)
Fig. 2
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
SHE1BS / SHE1GS / SHE2BS / SHE2GS
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of
the circuit cable, fuse, or circuit breaker
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
This product is Class I and must be earthed
This product is IP65 rated
INSTALLATION
Note - Microwave sensors may not be suitable for all installations, for example enclosed spaces, as they are
able to detect movement through non-metallic surfaces like plasterboard and thin doors.
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
Remove the diffuser by unscrewing the four hex screws at the front of the diffuser
Using the baseplate as a template, mark the location for, and drill the fixing holes ensuring not to
infringe with any gas/water pipes or electrical cables
Feed the mains cable through the rubber grommet to retain IP rating, and secure the baseplate to the
surface
Ensuring correct polarity is observed, carefully wire as shown in Fig. 1
Fig. 1
Ensure the earth lead on the LED plate is secured correctly to the earth lead on the body of the fitting
Fix the LED tray to the body
Choose the required colour temperature by means of the three-position switch (see Fig. 2)
Fig. 2
Connect the luminaire to the mains supply ensuring the correct polarity is observed (see Fig. 1): L - Live
(brown), E - Earth (green/yellow), N - Neutral (blue). The earth terminal is non-functional and only provided
for convenience
Please see DIP switch layout to set up the sensor
Replace the diffuser ensuring seal is in place
Switch on and check for correct operation, ensuring the green indicator LED is illuminated
We recommend, on commissioning the installation, a minimum charge period of 24 hours before
carrying out an emergency duration test
SENSOR DIP SWITCH LAYOUT
DIP SWITCH SETTINGS
Please see DIP switch layout to set up the sensor
Replace the diffuser ensuring seal is in place
Switch on and check for correct operation
SENSOR DIP SWITCH LAYOUT
DIP SWITCH SETTINGS
SENSOR DIP SWITCH LAYOUT
DIP SWITCH SETTINGS
Please see DIP switch layout to set up the sensor
Replace the diffuser ensuring seal is in place
Switch on and check for correct operation
SENSOR DIP SWITCH LAYOUT
DIP SWITCH SETTINGS
Please see DIP switch layout to set up the sensor
Replace the diffuser ensuring seal is in place
Switch on and check for correct operation
SENSOR DIP SWITCH LAYOUT
DIP SWITCH SETTINGS
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
This product is not suitable for installation in or near a coastal or marine environment.
WARRANTY
This product has a warranty of 5 years (excluding battery) from date of purchase. Failure to install this product
in accordance with the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal
of the batch code will invalidate the warranty. If this product should fail within its warranty period, it should
be returned to the place of purchase for a free of charge replacement. ML Accessories does not accept
responsibility for any installation costs associated with the replacement product. Your statutory rights are not
affected. ML Accessories reserve the right to alter product specification without prior notice.
GENERAL
This product contains a light source of energy efficiency class D to Regulation (EU) No. 2019/2015.
This product contains a non-replaceable LED light source and a control gear which can be replaced by a
professional.
Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not
use aggressive cleaning products or solvents which may damage the product.
This product is non-dimmable.
This product should be dismantled for disposal when it reaches the end of its life. Please see website for
dismantling instructions.
This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities
for where facilities exist.
The batteries in this luminaire are Lithium Ion and must be disposed of correctly. Please contact the local
authorities for the disposal of this toxic waste.
TESTING FOR EMERGENCY LUMINAIRES
Recommended routine test procedure in accordance with BS5266
Daily check – check LED charge indicator is illuminated
Monthly functional test - simulate a mains supply failure for approx. 30 seconds by operation of key switch
or switching off circuit breaker. Ensure normal supply is restored after test and ensure charge indicator is
illuminated
Annual three-hour duration test - simulate a mains supply failure for three-hour continuous test by
operation of key switch or switching off circuit breaker. Ensure normal supply is restored after test and
ensure charge indicator is illuminated
If the luminaire fails any of the above tests, please contact a qualified electrician. See below for test record
sheet
230V 50Hz, IP65, Class I, Non-Dim, Ta -20~50
AVOCT21_V2
AVJUL22_V3
134
-20°C~
50°C
TA
SUPPLIED BY:
(UK) MANUFACTURER
ML ACCESSORIES LTD, UNIT E CHILTERN PARK, BOSCOMBE ROAD, DUNSTABLE LU5 4LT,
WWW.MLACCESSORIES.CO.UK
(EU) AUTHORISED REPRESENTATIVE
SLV LIGHTING GROUP, DAIMLERSTRASSE 21-23,
52531 ÜBACH-PALENBERG, GERMANY
EMAIL: EPREL@GROUP.SLV.COM
Manufacturers Declaration of Conformity
For ML Accessories (Knightsbridge)
Electrical products in accordance with CE marking
ML Accessories Ltd. Declare that all products have been designed, manufactured, and tested in
accordance with the requirements of the relevant legislation
CE marking legislation
In Accordance with the following Directives:
2014/35/EU Low Voltage Directive
2014/30/EU EMC Directive
2014/53/EU Radio Equipment Directive
Including Legislation
1907/2006 REACH
2015/863 RoHS
2021/341 ERP
Safety Standards
Full individual declarations and specific safety standards applicable to relevant product series can be found on
our website www.mlaccessories.co.uk
We hereby declare that the equipment named above has been designed to comply with the relevant
sections of the above referenced specifications. The product complies with all essential requirements of
the directives.
Scott Brewer Catherine Connolly
Technical Manager CEO
ML Accessories Ltd. Unit E Chiltern Park, Boscombe Road, Dunstable. Bedfordshire, LU5 4LT
This declaration becomes invalid if technical or operational modifications are introduced without ML Accessories Ltd. written consent.
Manufacturers Declaration of Conformity
For ML Accessories (Knightsbridge)
Electrical products in accordance with UKCA marking
ML Accessories Ltd. declare that all products have been designed, manufactured, and tested in
accordance with the requirements of the relevant legislation
UKCA marking legislation
UK SI 2016 No. 1091 Electro Magnetic Compatibility Regulations 2016
UK SI 2016 No. 1101 The Electrical Equipment (Safety) Regulations 2016
UK SI 2012 No. 3032 Restriction of the use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012
UK SI 2017 No. 1206 Radio Equipment regulations 2017
UK SI 2021 No. 1095 The Ecodesign for Energy-Related Products and Energy
Information (Lighting Products) Regulations 2021
Included Legislation
UK SI 2008 No. 2852 UK REACH
UK SI 2013 No. 3113 WEEE
Safety Standards
Full individual declarations and specific safety standards applicable to relevant product series can be found on
our website www.mlaccessories.co.uk
We hereby declare that the equipment named above has been designed to comply with the relevant
sections of the above referenced specifications. The products comply with all essential requirements of
the directives.
Scott Brewer Catherine Connolly
Head of Technical CEO
ML Accessories Ltd. Unit E Chiltern Park, Boscombe Road, Dunstable. Bedfordshire, LU5 4LT
This declaration becomes invalid if technical or operational modifications are introduced without ML Accessories Ltd. written consent.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

ML Accessories SHE1GEMS User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI