Gigabyte GS-R113V-RH System Installation Manual

Category
External hard drives
Type
System Installation Manual

This manual is also suitable for

System Installation Guide
GS-R113-RH Series
GS-R113V-RH
GS-R113L-RH (OEM Model)
1U Rack Mount Server
AMD
®
AM2 Processor Motherboard
Rev. 1.1
2
GS-R113-RH Series Rack Mount Server
Table of Content
Safety, Care and Regulatory Information................................................4
WARNING!...............................................................................................7
Introduction..............................................................................................8
Contents Packages ................................................................................8
GS-R113-RH Series Model List.............................................................8
Chapter 1Features Summary ..................................................................9
Chapter 2 System Hardware Installation ............................................... 11
Step 2-1: Chassis Removal and Installation .................................................................11
Step 2-2: CPU Installation............................................................................................... 12
Step 2-3: Heat Sink Installation....................................................................................... 13
Step 2-4: Memory Installation ........................................................................................ 13
Step 2-5: PCI Expansion Card Installation.................................................................... 14
Step 2-6: Hard Disk Drive Installation ............................................................................ 15
GS-R113V-RH.................................................................................................................. 15
GS-R113L-RH (OEM Model) .......................................................................................... 16
Step 2-7: FAN Duct Removal and Installation.............................................................. 17
Chapter 3 Appearance of GS-R113-RH ................................................18
3-1: Front View of GS-R113V-RH.................................................................................. 18
3-2: Front View of GS-R113L-RH (OEM Model) .......................................................... 18
3-3: Rear View of GS-R113L-RH/GS-R113V-RH......................................................... 19
3-4: Switch and LED Indicators Introduction ................................................................. 20
3-5: LAN LED Description............................................................................................... 23
3-6 : Connector Icon Description ................................................................................... 24
Chapter 4 Motherboard Layout & Jumper Setting................................25
4-1: GA-3PXSL1-RH Motherboard Components .......................................................... 25
4-2: Jumper Setting ......................................................................................................... 27
3
Table of Content
Chapter 5 BIOS Setup ..........................................................................28
Main...........................................................................................................30
Advanced ...................................................................................................35
Advanced BIOS Feature................................................................................................. 36
Advanced Chipset........................................................................................................... 39
Integrated Peripherals...................................................................................................... 41
Power Management Setup ............................................................................................. 49
PnP/PCI Configuration..................................................................................................... 51
Security ......................................................................................................53
Boot............................................................................................................54
PC Health...................................................................................................55
Exit .............................................................................................................57
Chapter 6 Application Driver Installation ...............................................58
A.NVDIA Chipset Driver Installation............................................................................... 58
B.nVIDIA VGA Driver Installation.................................................................................... 64
C.Marvell LAN Driver Installation .................................................................................. 66
D.DirectX 9.0 Driver Installation...................................................................................... 69
Chapter 7 Appendix..............................................................................72
7-1: Acronyms................................................................................................................. 72
4
GS-R113-RH Series Rack Mount Server
Safety, Care and Regulatory Information
Important safety information
Read and follow all instructions marked on the product and in the documentation before you operate
your system. Retain all safety and operating instructions for future use.
* The product should be operated only from the type of power source indicated on the rating label.
* If your computer has a voltage selector switch, make sure that the switch is in the proper position for
your area. The voltage selector switch is set at the factory to the correct voltage.
* The plug-socket combination must be accessible at all times because it serves as the main disconnect-
ing device.
* All product shipped with a three-wire electrical grounding-type plug only fits into a grounding-type power
outlet. This is a safety feature. The equipment grounding should be in accordance with local and national
electrical codes. The equipment operates safely when it is used in accordance with its marked electrical
ratings and product usage instructions
* Do not use this product near water or a heat source.
* Set up the product on a stable work surface or so as to ensure stability of the system.
* Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure you
provide adequate space around the system for ventilation when you set up your work area. Never insert
objects of any kind into the ventilation openings.
* To avoid electrical shock, always unplug all power cables and modem cables from the wall outlets
before removing covers.
* Allow the product to cool before removing covers or touching internal components.
Precaution for Product with Laser Devices
Observe the following precautions for laser devices:
* Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser device other than
those specified in the product's documentation.
* Only authorized service technicians should repair laser devices.
Precaution for Product with Modems, Telecommunications, ot Local Area
Network Options
Observe the following guidelines when working with options:
* Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical
shock from lightning.
5
Safety Information
* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.
* Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.
* Disconnect the modem cable before opening a product enclosure, touching or installing internal
components, or touching an uninsulated modem cable or jack.
* Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.
Federal Communications Commission (FCC) Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission
limits. Neither the provider nor the manufacturer are responsible for any radio or television interference
caused by using other than recommended cables and connectors or by unauthorized changes or
modifications to this equipment. Unauthorized changes or modifications could void the user's authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
FCC part 68 (applicable to products fitted with USA modems)
The modem complies with Part 68 of the FCC Rules. On this equipment is a label that contains, among
other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment.
You must, upon request, provide this information to your telephone company.
If your telephone equipment causes harm to the telephone network, the Telephone Company may
discontinue your service temporarily. If possible, they will notify in advance. But, if advance notice is not
practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with
the FCC.
6
GS-R113-RH Series Rack Mount Server
Your telephone company may make changes in its facilities, equipment, operations, or procedures that
could affect proper operation of your equipment. If they do, you will be notified in advance to give you an
opportunity to maintain uninterrupted telephone service.
The FCC prohibits this equipment to be connected to party lines or coin-telephone service.
The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part
68, Sec. 68.381 (c) (3)).
/ for Canadian users only /
Canadian Department of Communications Compliance Statement
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital
apparatus as set out in the radio interference regulations of Industry Canada.
Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux
appareils numeriques de Classe B prescrites dans le reglement sur le brouillage radioelectrique edicte par
Industrie Canada.
DOC notice (for products fitted with an Industry Canada-compliant modem)
The Canadian Department of Communications label identifies certified equipment. This certification
means that the equipment meets certain telecommunications network protective, operational and safety
requirements. The Department does not guarantee the equipment will operate to the user satisfaction.
Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the
local Telecommunications Company. The equipment must also be installed using an acceptable method
of connection. The customer should be aware that compliance with the above conditions might not prevent
degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated
by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions,
may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system, if resent are connected together. This precaution
may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
7
Safety Information
NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total
load to be connected to a telephone loop which is used by the device, to prevent overloading. The
termination on a loop may consist of any combination of devices subject only to the requirement that the
sum of the Load Numbers of all the devices does not exceed 100.
/ for European users only /
CAUTION
Danger of explosion if battery is incorrectly
replaced.
Replace only with the same or equivalent
type recommended by the manufacturer.
Dispose of used batteries according to the
manufacturer’s instructions.
Computer motherboards and expansion cards contain very delicate Integrated Circuit (IC) chips. To
protect them against damage from static electricity, you should follow some precautions whenever you
work on your computer.
1. Unplug your computer when working on the inside.
2. Use a grounded wrist strap before handling computer components. If you do not have
one, touch both of your hands to a safely grounded object or to a metal object, such as
the power supply case.
3. Hold components by the edges and try not touch the IC chips, leads or connectors, or
other components.
4. Place components on a grounded antistatic pad or on the bag that came with the
components whenever the components are separated from the system.
5. Ensure that the ATX power supply is switched off before you plug in or remove the ATX
power connector on the motherboard.
WARNING!
8
GS-R113-RH Series Rack Mount Server
; Chassis ; GA-3PXSL1-RH Motherboard (Installed)
; Power Supply (Installed) ; FAN Duct x 1
; CPU Heat Sink x 1 ; Standard Floppy Drive (Installed)
; Silm type CD-ROM drive (Installed) ; Cables (RJ45)
; GS-R113-RH Series System Installation Guide ; Case Handle Kit x 2
; Driver CD for motherboard driver & utility
Introduction
Welcome to Gigabyte GS-R113L/V-RH Rack mount Server System Installation Guide. The guide
provides instructions for configuration hardware for the GS-R113L/V-RH your system.
This installation guide will assist you in installing all the essential components for the sever system.
For your protection, please read and undertand all of the safety and operating instructions regarding your
Gigabyte Server and retain for future reference. The procedures in this guidebook assume that your are
a system or network administrator experienced in installing similar hardware.
When opening the package, please ensure the system components are not damaged during the
shipping. Using the following checklist to verify the contents. If any component is missing or damaged
in the system, please contact your vendor immediately.
Contents Packages
GS-R113-RH Series Model List
GS-R113V-RH (Supports 2 hot-swap SATA HDDs)
GS-R113L-RH (Supports 2 internal SATA HDDs; OEM Model)
9
Feature Summary
Motherboard GA-3PXSL1-RH
Processor Supported Supports AMD
®
Opteron
TM
100 series (Socket AM2) processor
AMD
®
Single/Dual Core in AM2 socket
L2 cache on-die per processor from 1M
Chipset NVIDIA
®
GeForce 6100 Chipset
NVIDIA
®
nForce 430 Chipset
System Memory:
Memory Capacity 4 x DDRII socket up to 8 GB
Memory Type Un-buffered DDRII-533/667
DIMM Size Support 512MB, 1GB, 2GB memory
Expansion Slot 1 x Low Profile PCI-E (Half-High/Half-Length)
1 x Full-Size PCI add-on card (Full-High/Half-Length)
SATA RAID controller Build in NVIDIA
®
nForce 430 chipset
Supports Software RAID 0,1
Cooling Fans: 5 X System Fan
2 X Power Fan
Integrated LANs:
Controller Marvell 88E8056 GbE controller/Marvell 88E1116 GbE PHY
Supports WOL, PXE
Integrated Graphics:
Controller Integrated in NVIDIA
®
GeForce 6100 Chipset
Graphics Memory 256MB (Shared)
Mass Storage System 2 x Internal SATA HDDs (GS-R113L-RH)
2 x hot-swap SATA HDDs (GS-R113V-RH)
1 x Standard Type FDD
1 Slim Type CD-ROM
Super I/O
Controller ITE IT8712F-A
Chapter 1 Features Summary
10
GS-R113-RH Series Rack Mount Server
Built-in I/O 2 x Serial port (1 by cable)
3 x USB 2.0 connectors (2x rear USB, 1x Front USB)
1 x VGA connector
2 x RJ45 LAN ports
P/S 2 Keyboard and Mouse Connectors
1 x RJ45 on front for console redirection
System BIOS:
BIOS Type Phoenix
®
AWARD BIOS, Multi-boot BBS 1.0 Compliant4Mb
Flash Memory
Special Features BIOS HW Monitoring reporting (The values monitored by HW
Monitoring chipset)
Console Redirection via COM ports
Wake On LAN
ACPI 1.0 Compliant/ ACPI defined S1, S3, S4, and S5
Environment
Ambient Temperature Operating Temperature: 5
o
C to 35
o
C
Non-operating Temperature: 0
o
C to 50
o
C
Relative Humidity 10-80% operating Humidity at 30
o
C
Safety Regulations FCC, CE, BSMI, CB, Win2000
System Dimention: 427.5mm x 521mm x 42.6 mm
Electrical Power Supply Single Power Supply 250W
11
Hardware Installation Process
Please observe the safety information in chapter “Important Safety Information”
Do not expose the server to extreme environmental conditions. Protect it from dust,
humidity, and heat.
Step 2-1: Chassis Removal and Installation
Step 1 Loosen the thumbscrew from the back of the server.
Step 2 Push down the indentation located at two sides of the chassis, and slide toward to remove the
top cover.
Step 3 Reverse Step 1, and 2 to replace the chassis cover.
Chapter 2 System Hardware Installation
Step 2
Note: Before installing CPU, you must remove the FAN duct. For FAN duct removal, please
see Sub-section 2-7 “FAN Duct Removal and Installtion” for detail instruction.
Step 1
12
GS-R113-RH Series Rack Mount Server
Step 2-2: CPU Installation
Please make sure the CPU type and speed that are supported by the motherboard.
Step 1
Step 2
Step 1. Check the CPU pins are not bent. Raise the locking lever next to the socket prior to installing
the CPU.
Step 2. The pin 1 location is designated on the CPU by a copper triangle that corresponds to a triangle
marking on the socket as shown in Fig. 2.
Step 3. Insert the CPU with the correct orientation. The CPU only fits in one orientation. When CPU
is placed into socket properly, push the locking lever back into locked position.
13
Hardware Installation Process
Step 2-3: Heat Sink Installation
Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well
remember to apply the thermal conductivity compound on the CPU.
Step 2 Seat the heat sink in the retention modules with the four screws. Installation completed.
Step 2-4: Memory Installation
Step 1. Unlock a DIMM socket by pressing the retaining clips outwards.
Step 2. Aling a DIMM on the socket such that the notch on the DIMM exactly match the notches in
the socket.
Step 3. Firmly insert the DIMMinto the socket until the retaining clips snap back in place.
Step 4. When installing the DIMM into the DIMM socket, we recommend to populate one
DIMM in Channel A module and one in Channel B module for best performance.
Please note that each logical DIMM must be made of two identical DIMMs having the
same device size on each and the same DIMM size.
Step 5. Reverse the installation steps when you wish to remove the DIMM module.
Step 2
Step 1
14
GS-R113-RH Series Rack Mount Server
Step 2-5: PCI Expansion Card Installation
GS-R113-RH Series provides expansion riser slots for one PCI 32/33MHz slot and one PCI-E x8
slot. To install the peripheral, please go through the following steps.
Note!! Before installing the PCI expansion card, please check the card size limitation. Size limitation
for PCI-X full-height/full-length is 228.5 mm x 91.5 mm; size limitation for Low-Profile Card : 167.5 mm
x 56 mm .
Step 1 Loosen the riser bracket screws.
Step 2 Lift the riser bracket slightly, then pull it out from the server chassis.
Step 3 Unlock the screw on the riser bracket to remove the PCI bracket. Align the expansion card
with the guiding groove. Slide the expansion card into the slot until the card firmly seats.
Step 4 Align the riser bracket to the system module (see the arrow direction mark 1), and push
it to locked position.
Step 5 Reverse Step 1 & 2 to lock the riser bracket firmly. Installation completed.
Step 1
Step 2
Step 3
Step 4
15
Hardware Installation Process
Step 2-6: Hard Disk Drive Installation
GS-R113V-RH
Step 1 Press the release button and pull the blank out of the drive bay.
Step 2 Slide hard disk into blank and secure it with screws
Step 3 To replace the hard drive blank, slide the blank into the bay until it locks into place. Connect cable
and power.
Step 4 Reverse step 1, 2, and 3 to complete the HDD installtion.
Release button
Step 1 Step 2
16
GS-R113-RH Series Rack Mount Server
Step 1 Lossen the screws securing the hard drive plate.
Step 2 Slide toward to remove the hard drive plate from system.
Step 3 Place hard disk on the plate and lock hard drive with 4 screws.
Step 4 Replace the hard drive plate, slide the blank into the bay until it locks into place.Connect HDD
power cable.
Step 5 Reverse step 1, 2, 3 and 4 to complete the HDD installtion.
GS-R113L-RH (OEM Model)
Remove
Step 1
Step 2
Step 4
Step 3
17
Hardware Installation Process
Step 2-7: FAN Duct Removal and Installation
Step 1 Lift up to remove the fan duct.
Step 2 To Install the FAN Duct, just simply place the fan duct on the top of heat sink.
18
GS-R113-RH Series Rack Mount Server
3-1: Front View of GS-R113V-RH
Chapter 3 Appearance of GS-R113-RH
3-2: Front View of GS-R113L-RH (OEM Model)
MOR-DCepyTmilS
ypoolFdradnatS
rotcennoCBSU
sDEL
)noitcerideRelosnoCroF(54JR
MOR-DCepyTmilS
ypoolFdradnatS
rotcennoCBSU
sDEL
)noitcerideRelosnoCroF(54JR
sDDHATASpawsysaE
System Appearance
19
3-3: Rear View of GS-R113L-RH/GS-R113V-RH
rewoP
troPAGV
troPMOC
tolSresiReliforPwoL
tolSresiRhtgnel-lluF/ezis-lluF
rotcennoCdraobyeK
rotcennoC
esuoM
srotcennoCBSU
stroP2&1NAL
20
GS-R113-RH Series Rack Mount Server
3-4: Switch and LED Indicators Introduction
Power/Sleep
LAN1/2 Activities
HDD
Reset BTN
Name
Power
HDD
LAN1
Activity
LAN2
Activity
Color Condition Description
Green On Power On
Green Blink Sleep (S1)
-- Off Power Off (S4/S5)
Green Blink Hard Disk Drive Access
-- Off No Access and No HDD Fault
Green On LAN Link / No access
Green Blink LAN access
-- Off Idle
Green On LAN Link / No access
Green Blink LAN access
-- Off Idle
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73

Gigabyte GS-R113V-RH System Installation Manual

Category
External hard drives
Type
System Installation Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI