Sioux Chief 868-P6M Installation guide

Type
Installation guide

This manual is also suitable for

Typical Installation
868 Series Roof Drain
Sioux Chief Manufacturing Company | P: 1.800.821.3944 | F: 1.800.758.5950 | www.siouxchief.com 06-21
The graphic below should be used as a guide only. Always follow local plumbing and other
applicable codes for specic installation requirements in your area before installation.
Be sure to use the proper size and number of drains needed for the application. Always follow local plumbing and other
applicable codes. Wear gloves, safety glasses and other appropriate protective equipment.
Set drain into hole in roof deck. Drain should be supported by ange, or if needed/required, use the sump receiver to support
drain in roof deck. The sump receiver allows the drain to be installed level with the roof deck and reduce strain on the
waterproong around the drain ange. The sump receiver can be fastened to the roof deck if needed. Tack weld or use
button-head screws to secure sump receiver to roof deck.
Set drain into recess of sump receiver and install the underdeck clamp kit. The underdeck clamp fastens the drain body down
to the roof deck. Four thread rods install into underside of drain body. The round deck clamp engages structural member and
fastens to the thread rod with nuts/washers.
Trim any insulation as needed around the drain ange. Install all waterproong membrane and ashings in accordance with
waterproong manufacturer’s instructions. Install the thread rod, clamping collar, nuts/washers to securely compress the
completed waterproong layer(s) against the drain body/ange. Use a water block per roof manufacturer's instructions.
Connect drainage pipe. For PVC or ABS drains, solvent weld Sch. 40 DWV pipe into hub of drain body according to ASTM
standards. For cast iron drains, connect cast iron drain pipe to the drain outlet using a no-hub coupling.
Check drain assembly and pipe connection for leaks.
Attach dome strainer to clamping collar with three fasteners.
Dome Strainer
Clamping Collar
Sump Receiver
Underdeck
Clamp Kit Drain Pipe
Drain Body Roof Deck
Waterproong
Gravel
Insulation
  • Page 1 1

Sioux Chief 868-P6M Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI