Reliance UFH Heat Pump Underfloor Heating Kit Installation guide

Type
Installation guide
The Heatpump UFH kit provides an easy and quick way
to connect a heat pump to the manifolds feeding an
underfloor heating system.
Installation and Maintenance Instructions
Heatpump Underfloor
Heating Kit
U2P5M-37 5
F1L3E0 XA AZS
A
HEifgfh
iciency
Reliance Worldwide Corporation (UK) Ltd
Reliance Worldwide Corporation (UK) Limited is part of the RWC group based in Atlanta,
USA. This product falls within our Reliance Valves category, a global leader in the design
and manufacture of water control valves.
With group offices and manufacturing plants throughout the world RWC offers a wealth of
knowledge and expertise which is reflected throughout our products. Being part of many
specialised trade associations and having our own UKAS accredited laboratory, makes us
at the forefront of any new regulations or changes which impact the industry, and allows
for continuous product development and innovation, within our specialised product area.
General Info
The Reliance Heatpump UFH kit is a connection block for quickly and easily connecting
heat pump systems to underfloor heating manifolds.
The kit does not have any mixing or thermostatic capability, the flow that is supplied by
the heat pump or other energy source is channelled directly into the flow manifold and
the return flow is channelled directly back to the heat source.
If it possible that the system water temperatures could increase beyond a safe level for
the substrate being used then it is recomended that one of the RWC Thermomix or
Thermoguard thermostatic mixing products be used instead.
1
2
85°C
6 bar
Valve inlets 3/4” FBSP
Manifold connections 1” MBSP
Nickel Plated Brass
Fibre
Viton
Technical Specifications
Specifications
Maximum temperature
Maximum supply pressure:
Connections:
Materials
Body
Seals
O-Rings
Pressure Drop Graph
5
0
0
0.1
0.2
0.4
0.5
PRESSURE DROP (bar)
0.3
10 15 20
WATER FLOW RATE (l/min)
25 30
0.6
0.7
No return
flow to boiler
Dimensions
3
All dimensions in mm unless specified otherwise
80
72
210
103 30
U P M 3 F L E
X A S
2 5 - 7 5 1 3 0
A Z A
H i
g h
E f f i c i e
n c y
92 36
35
4
Pack Contents
Please check contents of pack before beginning installation.
Heatpump UFH Connection Block
Grundfos UPM3 Pump
including cable
Straight & Angled connectors
for Thermoguard UFH valve
1” fibre washers (Qty 2) with
straight connector tool
Pump washers
(Qty 2)
Connection elbow
Introduction
Designed to work with manifolds of all types, on 210mm centres. The Heatpump UFH kit
is a bolt on unit providing a quick and simple system to install.
Installation
Firstly firmly fix the distribution manifolds to the
wall leaving enough room beside the manifold to fit
the kit (see dimensions, Page 3).
Before beginning the installation identify all of the
components in the pack.
The Heatpump UFH kit comes with two return
ports. This means you can connect the main
heating system return to either side of the valve,
thus allowing the kit to sit on either side of the
manifold.
Once the orientation has been determined the
straight connector which connects the Heatpump
UFH kit to the manifold needs to be screwed into
the return port. This is tightened using the straight
connector tool supplied.
The angled connector can then be connected to either the flow or the return port on the
the supply pipework.
kit depending on the orientation of
5
Pump
Flow
Return
Return
or
6
Connect the Heatpump UFH kit body to the pump
using the pump nut which is pre-assembled ensuring
the pump washer is inserted. Please take note of the
directional arrow on the pump body.
Ensure the 1 ½” pump nut is fitted to the flow
connection elbow. If not, this can be slipped over the
flanged connection face.
Connect the nickel plated elbow to the pump using the
1 ½” pump nut, ensuring the pump washer is inserted.
Tighten the pump union connections.
Connect the elbow to the flow manifold by
means of the 1” MBSP
connection onto the flat faced union
connection, remembering to fit the 1” fibre
washer.
Connect the Heatpump UFH kit body to the
return manifold by means of the 1” MBSP
connection onto the flat faced union
connection again remembering to fit the 1”
fibre washer.
Thermoguard UFH Valve and Manifold orientation options:
Wiring
A fused spur should be provided adjacent to the manifold to provide power to the pump
and two port zone valve if fitted.
The pump is supplied with a plug-in cable for ease
of installation.
To comply with IEE regulations, the pump on the Thermoguard UFH Control Pack must
be provided with an earth. All wiring should be undertaken by a qualified installer and
must conform to IEE regulations.
7
U P M 3
F L E X A
S
2 5 - 7 5
1 3 0 A Z
A
H i
g h
E f f i c
i e n c
y
U P M 3
F L E X A
S
2 5 - 7 5
1 3 0 A Z
A
H i
g h
E f f i c
i e n c
y
U P M 3
F L E X A
S
2 5 - 7 5
1 3 0 A Z
A
H i
g h
E f f i c
i e n c y
U P M 3
F L E X A
S
2 5 - 7 5
1 3 0 A Z
A
H i
g h
E f f i c
i e n c y
Reliance Worldwide Corporation
(UK) Limited
Horton Road
West Drayton
UB7 8JL
United Kingdom
Tel: +44 (0) 1895 449233
rwc.co.uk
Reliance Worldwide Corporation (UK) Limited
reserves the right to make changes to the product
which may affect the accuracy of information
contained in
this leaflet. ZINS600001 - 02/20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12