Salus KL10 Installation And Wiring Manual

Type
Installation And Wiring Manual

Salus KL10 is an innovative wiring center that provides comprehensive control over various heating systems, including underfloor heating (UFH), radiators, and hot water. It features multiple thermostat connections, allowing you to manage up to eight zones independently or in two separate groups.

With its advanced capabilities, the KL10 offers a range of customization options. You can configure thermostat grouping for efficient zone management. Additionally, the built-in pump and boiler delay settings enhance system functionality by preventing premature boiler activation. The optional heat/cool changeover connection enables effortless switching between heating and cooling modes.

Salus KL10 is an innovative wiring center that provides comprehensive control over various heating systems, including underfloor heating (UFH), radiators, and hot water. It features multiple thermostat connections, allowing you to manage up to eight zones independently or in two separate groups.

With its advanced capabilities, the KL10 offers a range of customization options. You can configure thermostat grouping for efficient zone management. Additionally, the built-in pump and boiler delay settings enhance system functionality by preventing premature boiler activation. The optional heat/cool changeover connection enables effortless switching between heating and cooling modes.

KL10
Installation and wiring guide
www.salus-controls.com Technical Helpline 00000 000000 Maintaining a policy of continued product development SALUS Controls plc reserve the right to change
specication, design and materials of products listed on this installation guide without prior notice.
Issue Date: June 2014 Document Number 00105
SL L N
1
2
+
HOT WATER TIMER
MODEL VS10W
ROOM THERMOSTAT PRT
MODEL VS10W
THERMOSTAT
MODEL VS10W GROUP 2
THERMOSTAT
GROUP 2
THERMOSTAT
GROUP 2
DIAL THERMOSTAT
GROUP 1
DIAL THERMOSTAT
GROUP 1 CONTROL
THERMOSTAT
OPTIONAL UFH ZONE VALVE
FOR RADIATORS GROUPS
FUSE
FUSE
SUPPLIED CABLES
230V TO UFH PUMP
UNDERFLOOR HEATING MANIFOLD
1.5MM
2
CABLE (INSTALLER SUPPLIED)
1.5MM
2
CABLE (INSTALLER SUPPLIED)
1.5MM
2
CABLE
(INSTALLER SUPPLIED)
13 AMP FUSED CONNECTION UNIT
FUSED AT 3 AMPS
1.5MM
2
3 CORE
1.5MM
2
3 CORE
0.5MM
2
TWIN
ZONE 1
ZONE 1HOT WATER ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
SLNL SLNL SLNL SLNL SLNL SLNL SLNL
GROUP 2 GROUP 1
NL
++++ ++ ++-- --
SL SLNL
ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
SL L N
1
2SL L N
1
2
++
SL L N
1
2
+
SL L N
1
2
+
SL L N
1
2
+
SL L N
1
2
+
SL L N
1
2
+
1
2
+
OPTIONAL
PRT (RADIATORS
0.5MM
2
TWIN
L NLNLNLNLNLNLNLNLNLNLNLNLNLNLNLN
SL L
8
OPTIONAL OPTIONAL OPTIONAL OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
2
3
5
5
7
6
4
OUT
IN
1.5MM
2
CABLE
(INSTALLER SUPPLIED)
230V
OPTIONAL
CYLINDER STAT
1.5MM
2
CABLE
OUT
IN
(INSTALLER SUPPLIED)
COLOURS ARE INDICATIVE ONLY.
EXTRA CONNECTIONS MAY BE REQUIRED
AS PER MANUFACTURERS INSTRUCTIONS
1
IN
HW CYLINDER
THERMOSTAT
HEETING/
COOLING
FACTORY
FITTED
LINK
FACTORY
FITTED
LINK
FACTORY
FITTED
LINK
HW MOTORISED VALVE OVERHEAT STAT UFH PUMP BOILER ENABLE UFH MOTORISED VALVE
OUT IN OUTIN OUT IN OUTBR EA N OR GR BR EA N OR GRLNE
For PDF Installation guide please go to www.salus-controls.com
These instructions are applicable to the SALUS model
stated on the front cover of this manual only.
Warning
This product must be tted by a competent person, and
installation must comply with the guidance, standards and
regulations applicable to the city, country or state where the
product is installed. Failure to comply with the requirements
of the relevant guidance, standards and regulations could lead
to injury, death or prosecution.
Warning
Always isolate the AC Mains supply before installing or working
on any components that require 230 VAC 50Hz supply.
9
Meets the following EC Directives
• Electro-Magntic Compatibility directive 2004 / 108 / EC
• Low voltage Directive 2006/95/EC
iT600 Wiring Centre KL10 005_Layout 1 05/06/2014 16:23 Page 1
KL10
Installation and wiring guide
www.salus-controls.com Technical Helpline 00000 000000
When using option 2 refer to device
parameters on page xx of the manual.
Thermostat Grouping
The thermostats can work as individual units or in groups. There can be up to 2 groups of
thermostats per wiring centre. In order to work in groups the communications cable must be
connected to the wiring centre communications terminals (+ & -). The (-) terminals are
common to all thermostats. In order to assign the thermostat to group 1 or 2 then the
communications cable + must be connected to the relevant 1 or 2 + terminal.
This must be carefully removed or
replaced when removing or replacing
the wiring centre cover, being careful
to ensure the correct orientation.
Dip Switch Set Up
In order for the wiring centre to be able to control UFH
and Radiators, there is a need to turn o the UFH pump for
a zone when that zone is to be used for radiators.
Eg. When tting a zone for radiators or towel rail then the
Dip Switch for that zone should be switched to OFF.
The Dip Switches for this are located under the front lid.
When the zone switch is in the ON position the UFH pump
will run when that zone is calling for heat along with the
boiler. When it is in the OFF position then the UFH pump will
not run but the boiler will re.
There are three other function switches as well.
Pump & Boiler delay: This gives a three minute delay to
allow actuators to open before the boiler res.
Pump Only Delay: Delays only the UFH pump from ring
for three minutes.
Actuator NC or NO: This refers to Normally Open or
Normally Closed. This should be set to NC for JG products.
Motorised Valves, Pump, Boiler & Stat Connections Ribbon Connection
Fuses Status Neon’s
Thermostat Zones
Groups
1
2
Actuator Connections
Actuator connections corresponding to the thermostat
connections. Up to 2 cables can be used in each
connection (4 Actuators per Zone) If more, that number
needs to be connected, then an external junction box
will be needed. A maximum of xxx actuators can be
connected to a zone in this manner.
7
If hot water is part of a group then
the communication connection
must be connected to group 1.
8
5
3
2
6
4 8
Optional Cylinder Thermostat: If connecting the cylinder thermostat
directly to the timer then a link needs to be tted between IN and OUT.
Optional Hot Water Motorised Valve: Used if timed hot water is required.
Optional Overheat Thermostat: Used for connecting a pipe thermostat to
prevent over temperature water damaging sensitive oors. Remove the link
and connect the pipe thermostat so it is Normally Closed. The pipe stat will
open if overheating occurs and
the UFH pump will stop running.
Optional Boiler Enable: This Volt Free connection must come from the boiler
thermostat connection, when any zone calls for heat the Boiler enable will
close causing the boiler to run. If work is being carried out on the boiler then
power to and from the switch will cease. (Do not connect to the boiler IN
terminal by linking a 230V feed from the wiring centre)
Optional UFH Motorised Valve: If a UFH motorised valve is
tted then remove the link between OR and GR.
Optional Heat/Cool Changeover: This connection allows heat/cool
changeover of all thermostats using a single external switch (installer supplied).
Switch: Open-Heating Closed-Cooling
Option 1
Connect Cylinder
Thermostat to
wiring centre
Option 2
Connect Cylinder
Thermostat to RF
Thermostat for wire
free connection. A
link will be needed
between IN & OUT
as shown by arrow.
IN
HW CYLINDER
THERMOSTAT HW MOTORISED VALVE OVERHEAT STAT UFH PUMP BOILER ENABLE UFH MOTORISED VALVE
OUT IN OUT IN OUTBR EA N OR GR BR EA N OR GRLNE
ZONE 1 ZONE 2 ZONE 3 ZONE 4
SLNL SLNL SLNL SLNL SLNL
HW TIMER CONNECTION
THERMOSTAT CONNECTIONS 230V AC
230V AC
Hot Water Connections
IN
HW CYLINDER
THERMOSTAT
HEET
COO
HW MOTORISED VALVE OVERHEAT STAT UFH PUMP BOILER ENABLE UFH MOTORISED VALVE
OUT ININ OUT IN OUTBR EA N OR GR BR EA N OR GRLNE
ZONE 1 ZONE 2 ZONE 3 ZONE 4
SLNL SLNL SLNL SLNL SLNL SL
HW TIMER CONNECTION
THERMOSTAT CONNECTIONS 230V AC
230V AC
Sensor Terminals
Can be used for external AIR,
Floor sensor when congured
as thermostat. Can also be
used for cylinder thermostat
when connected for HW.
OPTONAL HOT
WATER
MOTORISED
VALVE
OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED
OPTONAL HOT
WATER
MOTORISED
VALVE
OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED
1
iT600 Wiring Centre KL10 005_Layout 1 05/06/2014 16:23 Page 2
  • Page 1 1
  • Page 2 2

Salus KL10 Installation And Wiring Manual

Type
Installation And Wiring Manual

Salus KL10 is an innovative wiring center that provides comprehensive control over various heating systems, including underfloor heating (UFH), radiators, and hot water. It features multiple thermostat connections, allowing you to manage up to eight zones independently or in two separate groups.

With its advanced capabilities, the KL10 offers a range of customization options. You can configure thermostat grouping for efficient zone management. Additionally, the built-in pump and boiler delay settings enhance system functionality by preventing premature boiler activation. The optional heat/cool changeover connection enables effortless switching between heating and cooling modes.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI