Sloan Valve 3305622 Installation guide

Type
Installation guide

This manual is also suitable for

DETECTIONANDACTIVATION
Urinals(EL-1500Sensor)
WhentheSensordetectsauser,aslowlyflashingredlightappearsinthe
Sensorwindow.Aftereight(8)toten(10)seconds,thelightflashesrapidlyto
indicatethattheSensoris armed.WhentheSensor nolongerdetects auser,
the Sensor immediatelyactivatesthe solenoidvalve.
WaterClosets (EL-1500-LSensor)
DetectionandactivationarethesameasfortheUrinalEL-1500Sensorshown
aboveexcept when the Sensor no longer detectsa user, the Sensoractivates
the solenoidvalveaftera three (3) second delay.
TheEL-1500urinalandEL-1500-Lcloset selfadaptiveSensorsareequipped
with a“SentinelFlushfeature.Theseunitsautomaticallyactivatethesolenoid
everytwenty-four (24) hours afterthe lastuse.
Lavatories(EL-1500-LLandEL-1500-LL-TSensors)
WhentheSensordetectsauser,aslowlyflashingredlightappearsinthe
Sensorwindow.Aftertwo(2)seconds,thelightflashesrapidlyandtheSensor
immediatelyactivatesthesolenoidvalvetobeginwaterflow.Thesolenoidvalve
remainsopen aslong astheuserisdetectedandfortwo(2)secondsafterthe
userisnolongerdetected.TheEL-1500-LL-TSensorissettoactivatethe
solenoidforamaximumofthirty(30)secondsbeforeautomaticallyshuttingoff.
ForinformationconcerningtroubleshootingSloanOPTIMAandRoyal
Flushometervalves,consultourRepairandMaintenanceGuidesorcontact
your localSloan Representative.
Iffurtherassistanceisrequired,pleasecontacttheSloanValveCompany
Installation Engineering Departmentat847-671-4300.
NOTICE:Theinformationcontainedinthisdocumentissubjecttochange
withoutnotice.
SLOANEL-1500 SERIES
SELFADAPTIVEOPTIMA
®
SENSOR
TheEL-1500SeriesOPTIMASensorrepresentsthemostadvancedtechnology
usedinanysensoroperatedplumbingproductavailabletoday.TheEL-1500
SeriesreplacestheolderEL-150SeriesSensorsthathavebeenusedwith
Sloan OPTIMAplumbing productsfor overfifteen years.
ABOUTTHE SLOANEL-1500SERIESOPTIMA
®
SENSOR
TheEL-1500SeriesOPTIMASensoristhefirstsensorusedwithaplumbing
productthat“thinks.” AnEL-1500Sensor adapts itself toits environment.The
Sensorselfadjustsitsownrangesettingbasedonwhatit“seesinfrontofit,
andthereforeneedsnomanualrangeadjustment.Itautomatically
compensatesforthedepthandreflectivityoftheoppositewallorstalldoorand
fortheambientlightingconditionsoftherestroom.Additionally,eachsensor
usesavisibleredlightthatflashestoindicatedetectionofauserorproblems
withthe electrical connection.TheEL-1500 urinal and EL-1500-L closet
Sensors incorporateaSentinel Flush(anautomaticflush every 24hoursafter
fixtureslastuse).Thisfeaturehelpstomaintainafresh andfilled fixture even
when the fixtureisnot used fora longperiod of time.
UsetoReplaceSloanEL-1500andEL-150SeriesOptimaSensors
© Copyright1998SloanValve Company Printed inU.S.A.
SLOANVALVECOMPANY
10500Seymour AvenueFranklinPark, IL60131
Phone:800-9-VALVE-9 or847-671-4300
Fax:800-447-8329 or847-671-4380
http://www.sloanvalve.com
OPTIMA
®
INSTALLATIONINSTRUCTIONS
SENSORREPLACEMENTKITS
EL-1500
UrinalSensor
(Codeno. 3305620)
EL-1500-L
WaterClosetSensor
(Codeno. 3305621)
EL-1500-LL
LavatorySensor
(Codeno. 3305622)
EL-1500-LL-T
LavatorySensor
with 30 Second TimeOut
(Codeno. 3305623)
ELSENSI.I.— Rev.1 (10/98)
CodeNo. 0816196
Certified Listed
INSTALLATION AND REPLACEMENT
1. Disconnect 24 VAC power supply at the transformer or the fusebox.
2. Remove the Cover Plate and old Sensor from the wall installation. Use a
5/64" hex wrench to remove the Cover Plate Screws.
3. Connectone24VACleadtotheSensorterminallabeled“24VACIN.”(See
Figure 2.)
On an old three-wire EL-150 series Sensor, this wire was connected to
the BLACK Sensor lead.
On an old four-wire EL-150 series Sensor, this wire was connected to
the BROWN Sensor lead.
4. Connect one Solenoid lead to the Sensor terminal labeled “TO VALVE.”
(See Figure 2.)
On an old three-wire or four-wire EL-150 series Sensor, this wire was
connected to the RED Sensor lead.
5. Connect the remaining 24 VAC lead to the remaining Solenoid lead.
Onan oldthree-wire EL-150seriesSensor, thesewireswere connected
to the WHITE Sensor lead.
On an old four-wire EL-150 series Sensor, these wires were connected
to the YELLOW and BLUE (or in very early models, the inner BROWN)
Sensor leads.
6. On Water Closet installationsonly, connectthe OverrideButton (shown as
the Override Switch in Figure 1 Wiring Diagram) parallel to the EL-1500-L
Sensor.
7. The illustration of the Sensor on the front cover of these installation
instructions shows an orientation arrow on the Lens side of the Sensor.
Reinstall the Sensor with the arrow pointing UP. Replace the Cover Plate
and tighten the Cover Plate Screws.
8. Reconnect the 24 VAC power supply at the transformer or the fusebox.
START-UP MODE
The self adaptive sensor automaticallyadapts to thesurrounding environment
when 24 volt supply is activated.No manual adjustments are required.
Start-upmode willtakeapproximatelyfive(5) minutestocomplete itscycleand
is important that no non-permanenttarget is present at thistime. A continuous
redlightvisibleinsensorwindow indicatessensorisinthe start-upmode. Ifthe
red light isflashing, thisindicates that thesensor is pickingup a target.Unless
thistarget isa permanentfixtureinthe sensor’senvironment(i.e.,a wallorstall
door),itmustberemovedfromtheviewofthesensor.Ifthistargetispermanent,
the sensor will adapt itself around this target. In this case, the start-up mode
may take up to ten (10) minutes. When the start-up cycle is completed, there
will be no light visible in the sensorwindow.
Note: If the 24 voltpower supply isever interrupted for longerthan fifteen(15)
seconds, the start-up mode automaticallybegins when power is restored.
Incorrectwiringorashortinthe24voltpowersupplyisindicatedbyacontinuous
warningsignalseenintheSensorwindow.Thevisibleredlightflashesan“SOS”
signal: three (3) slow, three (3) fast,three (3) slow flashes.
120 VAC
Figure 1
WIRING DIAGRAM
NOTE: A MAXIMUM OF TEN (10) SENSORFLUSHOMETER OR THREE (3)
LAVATORY FAUCETUNITS CAN OPERATE FROMONE (1) SLOANEL-154
TRANSFORMER. CLASS2 UL LISTED, 48 VA (MIN.)AT 24 VAC,PLATE MOUNTED.
24 VAC
120 VAC SOURCE
COMMON
GND
EL-1500 SERIES
SENSOR
OVERRIDE
SWITCH
COIL WIRE
GROUND
SCREW IN
SOLENOID
HOUSING
UNIT #1
UNIT #2
THRU #10
(IF USED)
EL-1500 SERIES
SENSOR
OVERRIDE
SWITCH
COIL WIRE
GROUND
SCREW IN
SOLENOID
HOUSING
24 VAC COIL
24 VAC COIL
OVERRIDE SWITCH USED WITH
WATER CLOSETSONLY.
EL-1500 SERIES
SENSOR
“TO VALVE”
CONNECTION
“24 VAC IN”
CONNECTION
Figure 2
  • Page 1 1