Roche cobas Liat Reference guide

Type
Reference guide

Roche cobas Liat is an advanced molecular diagnostic system that delivers accurate and reliable results in just 20 minutes. It features easy-to-use touchscreen interface, automated sample processing, and connectivity to Roche's cobasinfinity middleware platform. With the capability to perform PCR amplification and detection in a single-use cartridge, cobas Liat offers a wide range of diagnostic tests for infectious diseases, including influenza, strep throat, and chlamydia.

Roche cobas Liat is an advanced molecular diagnostic system that delivers accurate and reliable results in just 20 minutes. It features easy-to-use touchscreen interface, automated sample processing, and connectivity to Roche's cobasinfinity middleware platform. With the capability to perform PCR amplification and detection in a single-use cartridge, cobas Liat offers a wide range of diagnostic tests for infectious diseases, including influenza, strep throat, and chlamydia.

Instruction
The cobas
®
Liat
®
Advanced Tools Key is able to perform a variety of functions, including backing up and restoring data,
and syncing lots between cobas
®
Liat
®
Analyzers.
For the remainder of this document, the cobas
®
Liat
®
Analyzer will be referred to as the Analyzer.
A. Instructions
NOTE: The following steps require an account with Administrator (ADMIN) or higher privileges.
1. Power on the Analyzer.
2. Log in using an Admin level user.
3. While in the Main Menu, insert the cobas
®
Liat
®
Advanced Tools Key (ATK) into a USB port in the back of the Analyzer.
The Advanced Tools menu is displayed after a few seconds.
4. Highlight the desired function and select Help to see a description of the function, or Select to perform the function.
5. Enter the Admin level user’s PIN when prompted to confi rm that the function is authorized.
6. Follow the on-screen instructions. See a description of each function below and its associated options.
7. When prompted, remove the USB key from the Analyzer, wait 5 seconds, and select OK.
8. To return to the Advanced Tools Menu, insert the ATK into the back of the Analyzer.
B. cobas
®
Liat
®
Advanced Tools Key Functions
Backup Results
Back up results from one or more
cobas
®
Liat
®
Analyzers to the ATK.
Performing this function appends the results on the Analyzer and the ATK; no results are overwritten.
Use this function to copy results from cobas
®
Liat
®
Analyzers.
Select “Backup” to copy results from the Analyzer to the ATK.
CAUTION! Results backed up by the ATK are stored as plain text les and so their content is accessible to unauthorized
persons. Ensure that you store backed up results safely and securely so that they are not accessible by unauthorized persons.
Backup Restore
Back up assay scripts, results, validated assay lots, and system settings from a fi rst
Analyzer
to the ATK, and/or restore
validated assay lots, and system settings from the ATK to a second
Analyzer. Note: Assay scripts and results are not restored.
Restoring overwrites the data on the second Analyzer.
Use this function to “clone” an Analyzer to a loaner Analyzer.
Users must be recreated on the second Analyzer.
Select “Backup” on the fi rst Analyzer (e.g., an Analyzer to be returned for service) to copy data to the ATK.
Select “Restore” on the second Analyzer (e.g., loaner Analyzer) to overwrite data from the ATK
to that Analyzer.
After completing and verifying the Restore, insert the ATK, and select “Clean Advanced Tools USB Key”
to erase all data on the ATK to prevent inadvertently overwriting the data on another Analyzer.
Sync Lots:
Sync assay lots between an Analyzer and the ATK.
Performing this function appends the assay lots on the Analyzer and the ATK; no data is overwritten.
Lots installed on an Analyzer using this function does not require validation via the Add Lot process.
Select “Yes” to merge assay lots stored on the ATK with the Analyzer.
cobas
®
Liat
®
Advanced Tools Key
Revision History
Document version Revision date Changes
1 November 2015 Roche Part number created
2 February 2016 Software version removed
Branding updated
3 May 2016 Content updated
NOTE: It is not possible to sync lots between versions 2.0.4 and 2.1 or higher.
Update Lots:
Back up assay lots from one
Analyzer
to the ATK, and/or restore assay lots from the ATK to another
Analyzer.
Restoring overwrites the assay lots on the Analyzer. Lots installed on an Analyzer using this function do not require validation
via the Add Lot process.
Select “Backup” to backup assay lots from the Analyzer to the ATK.
Select “Update” to overwrite assay lot data on the Analyzer with the data on the USB key.
Diagnostic Backup:
Back up recent assay results and diagnostics fi les for technical support purposes.
Select “Yes” to copy recent assay results from the Analyzer onto the ATK.
All Results Backup:
Back up all assay results and diagnostic fi les.
Select “Yes” to copy all assay results from the Analyzer onto the ATK.
Clean Advanced Tools Key:
Erase all data stored on the ATK.
C. Sending the Data to Roche Support
In order to provide Roche Support with data, please do the following:
1. Perform a Diagnostic Backup (or another function as requested).
2. Insert the cobas
®
Liat
®
Advanced Tools Key into a computer running Windows XP or later.
3. Open the USB drive root folder.
4. Execute Start.exe. The program will compress the data into a single fi le with the extension “.7zip”.
5. Your local Roche representative will provide further instructions for sending the data to Roche.
D. Document Information
This publication applies to cobas
®
Liat
®
Analyzer software version 3.0 and higher.
E. Roche Support
If you have any questions or problems, contact your local Roche representative.
In the U.S., contact the following number: 1-800-800-5973.
Patents: http://www.roche-diagnostics.us/patents
07710305001
© 2015-16 Roche Molecular Systems, Inc.
COBAS and LIAT are trademarks of Roche.
All other product names and trademarks are the property of their respective owners.
Roche Molecular Systems, Inc.
1080 US Highway 202 South
Branchburg, NJ 08876
USA
Roche Diagnostics GmbH
Sandhofer Strasse 116
68305 Mannheim
Germany
  • Page 1 1
  • Page 2 2

Roche cobas Liat Reference guide

Type
Reference guide

Roche cobas Liat is an advanced molecular diagnostic system that delivers accurate and reliable results in just 20 minutes. It features easy-to-use touchscreen interface, automated sample processing, and connectivity to Roche's cobasinfinity middleware platform. With the capability to perform PCR amplification and detection in a single-use cartridge, cobas Liat offers a wide range of diagnostic tests for infectious diseases, including influenza, strep throat, and chlamydia.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI