urban ambiance UQL3361 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the urban ambiance UQL3361 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ToolsRequired:Flatheadscrewdriver, Phillips screwdriver,pliers,wirecutters,wirestrippers,electricaltape,safetyglasses.
EstimatedAssemblyTime:30-45 minutes
Preparation:Identifyandinspectallpartsbeforebeginninginstallation.Checkpackagecontentlistanddiagramsbelowtobesureallpartsare
present.Ifanypartsaremissingordamaged,donotattempttoassemble,install,oroperatethefixture.Contactcustomerservice for replacement
parts.
Warnings and Cautions
1of2
BulbRecommended: 5 5( )MediumBaseDecorativeFilament60Wbulbs(provided),Maximum100W,Alternatebulb( )23WCFLMaximum.
Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.
These instructions are provided for your safety. It is very important you read them completely before installing the fixture. We strongly
recommend that a licensed, professional electrician perform the installation.
Disconnect fixture from power source before replacing bulbs. Make sure bulbs are given sufficient time to cool before removal. Do not subject
glass parts to any shock while in operation or shattering July result.
Package Contents
A
Hardware Contents
Fixture
Loop
x1
Shade
x5
AA
BB
CC
DD
EE
FF
II
Crossbar
x1
Lock Washer
x2
Hex Nut
x2
Nipple
x1
Canopy
Chain Loop
x1
Canopy Lock
Ring
x1
Ceiling Canopy
x1
GG Fixture Chain
x1
HH Quick Link
x2
D
STEP 1 Install Crossbar-
A. AA)Attach the Crossbar ( to the Outlet Box with the head of the
Green Ground Screw facing you. Secure it with Outlet Box Screws
(not included) Tighten until snug..
Figure 1
Outlet Box
Outlet Box Screw
(not included)
Green Ground
Screw AA
STEP 2 Install Canopy Chain Loop and Nipple-
*Pliers is required for this step.
A. Thread one Hex Nut (CC) to one end of the Nipple (DD) until it is at
least 0.25” from the end. Pass one Lock Washer (BB) over the end of
the Nipple (DD) and thread the Canopy Chain Loop (EE) onto the
Nipple (DD). By using pliers, thread the Hex Nut (CC) against the
Canopy Chain Loop (EE) and hand tighten until snug.
B. Thread another Hex Nut (CC) to the middle of the Nipple (DD). Place
another Lock Washer (BB) over the Nipple (DD) and then thread the
Nipple (DD) into the Crossbar (AA) until the Nipple (DD) is about
0.375” above the Crossbar (AA).
C. Remove the Canopy Lock Ring (FF) from the Canopy Chain Loop
(EE). Place the Ceiling Canopy (II) over the Canopy Chain Loop (EE)
against the ceiling to determine the correct position of the Nipple
(DD). Thread the Canopy Lock Ring onto the Canopy Chain Loop
(EE). Adjust the Nipple (DD) to allow the Ceiling Canopy (II) to rest
against the ceiling when held in place by the Canopy Lock Ring (FF).
AA
BB CC Step B
Step A
DD
CC
BB
EE
II
FF
Figure 2
B
Spacer
x1
C
Socket
Assembly
x1 Bulb
x5
F
Socket
Collar
x5
E
D. Remove the Canopy
Lock Ring (FF) and the
Ceiling Canopy (II).
Tighten the Hex Nut (CC)
against the Crossbar
(AA) to secure in place.
STEP 3 Attach Fixture Loop,
Center Stem, Socket
Assembly and Side
Arm together
-
A. Unfold support arms on Socket
Assembly to proper locations.
B. Place Spacer (B) over the
Nipple on the top of Socket
Assembly (C), secure by
threading the Fixture Loop (A)
onto the Nipple, hand tighten
until sung.
A
B
C
Figure 3
Installation Instructions: UQL3361
www.urbanambiance.com
2of2
STEP 7 -Install Bulb
A. This fixture uses Medium
Base Decorative Filament
60W bulb (F), Maximum
100W. Insert bulb and screw
snugly into place.
B. Insert bulb and screw snugly
into place.
Your fixture is now assembled
and ready to use. Enjoy!
Figure 7
Socket
F
STEP 5 - Wire Connections
A. Use standard wire connectors (not included) to make all wire
connections. (Connectors are not included with fixture.) Twist
connectors until wires are tightly joined together. Wrap each
connection with approved electrical tape and carefully stuff all the
connected wires into the Outlet Box.
White wire
from supply Ribbed side wire
from fixture
Black wire from
supply (or Red)
Smooth side wire
from fixture
Ground wire
from supply
Ground wire
from fixture
Figure 5
UQL3361
NOTE: ALL DIMENSIONS ARE ROUNDED
UP TO THE NEAREST 1/2"
FINISH: BLACK BRONZE
NOTE: FOUR LIGHTS
SHOWN FOR ILLUSTRATION
PURPOSES ONLY.
STEP 4 - Install Fixture Chain and
Ceiling Canopy
A. Adjust the Fixture Chain (GG) to your
desired length by removing the links if
needed.
Pliers is required for this step.
B. With the Fixture Chain (GG) not
attached to the Fixture Loop (A) and the
Canopy Chain Loop (EE), pull the
supply wires through the Fixture Chain
(GG) alternating links. After the wires
are through the Fixture Chain (GG),
pull the Supply Wires and the Ground
Wire through the Canopy Lock Ring
(FF) and the Ceiling Canopy (II) in
order.
C. Attach one end of the Fixture Chain
(GG) to the Fixture Loop (A) with one
Quick Link (HH). Lift the fixture and
Fixture Chain (GG) up And Attach the
other end of the Fixture Chain (GG)
onto the Canopy Chain Loop (EE) with
another Quick Link (HH). The fixture
will now hang safely. Close the chain
loop at the Ceiling Canopy Loop (EE).
D. Feed the Supply Wires and Ground
Wire through the Canopy Chain Loop
(EE) and Nipple (DD) into the Outlet
Box. Cut the wires leaving
approximately 8” of wire extending from
the Outlet Box.
E. Refer to Step 5 for wire connections.
F. Raise the Ceiling Canopy (II) and
Canopy Lock Ring (FF) up the Fixture
Chain (GG) and over the Canopy Chain
Loop (EE). Tighten the Canopy Lock
Ring (FF) onto the Canopy Chain Loop
(EE) until tight.
Suggested chain length for Ceiling
height :
8’ ceiling : use 9 links of chain and 2
quick links
9’ ceiling : use 18 links of chain and 2
quick links
10’ ceiling : use 27 links of chain and 2
quick links
*
Figure 4
DD
GG
II
Supply Wires
and Ground
Wire
EE
FF
HH
HH
A
(5)Medium Base
Decorative
Filament 60W
bulbs (provided),
Maximum 100W.
STEP 6 - Install Shade to
fixture
A. Place Shades (D) over the
sockets, secure by
threading Socket Collar (E)
onto the Socket, hand
tighten until sung. D
E
Socket
Figure 6
72”OVERALL HEIGHT
INCLUDES 48” CHAIN
AND 2 QUICK LINKS
(
)
19”
5.5”
8”Dia.
26”Dia.
5”Dia. 1”
1
2
www.urbanambiance.com
/