INSTALLATION
INTRODUCTION
IDENTIFICATION
Place the mounting base over the position
for mounting and mark the screw holes.
Use the two mounting holes on the surface
of the mounting base and ensure the “UP”
marking points upward. Drill suitable holes,
and then feed the supply cable through
the rubber seal on the rear of the mounting
base. Before xing the mounting base in
place, seal any holes in the wall through
which the supply cable passes so as to
The ‘Oberon’ Stainless Steel Wall Light is
suitable for permanent use and must be
installed by a licensed electrician.
The lamp housing consists of a tubular,
marine grade stainless steel body, each side
in two parts – a bezel and support section.
The support sections are in turn xed to a
mounting base. Make sure that the UP side
bezel which has internal thread is attached
to the UP side support section which has
external thread, and the DOWN side bezel
which has external thread is attached to
the DOWN side support section which has
internal thread. (Refer Fig1)
weatherproof it. Secure mounting base
with supplied screws, again ensuring the
“UP” marking is pointed upwards.
(Refer Fig.2)
Mounting Holes
Drilled Holes
Mounting Base
Rubber Seal
UP
DOWN
Fig. 02
WIRING
The terminal block wired to the rear of
the light must be wired to the switched
active, neutral and earth of the lighting
circuit to which it is being connected.
Connect in accordance with Fig.3.
ACTIVE BROWN
To
Internal
Connection
To
House
Wiring
L
GREEN/YELLOW
BLUE
GREEN/YELLOW
NEUTRAL
EARTH
N
Fig. 03
Double check all connections and ensure
all terminal block screws are tight. Press
the terminal block in position on the
plastic pins in mounting base and ensure
that the rubber seal is in place on the
front of the mounting base. Fit the base
cover over the mounting base, xing it in
place with the ‘o’ rings and dome nuts
provided.
SETTING UP
Fix the bulb by unscrewing the front
bezels of the lampholders and inserting
bulbs. (Bulb is GU10 type halogen bulb,
rated 250V 35W max.). The bulbs lock
in place with a 1/8 twists clockwise and
then ret the front bezels
This product is suitable for permanent
use. The globes shall not be directed at,
nor placed near any object within 0.5m
from the front of the lamp.
BULB REPLACEMENT
Use only bulbs of same type and rating.
(Bulbs are GU10 type halogen bulb,
rated 250V 35W max.). If the light
has been working, allow to cool before
handling to replace a bulb.
Remove bulb by unscrewing front bezel
and twisting bulb 1/8 turn anticlockwise.
It should then pull out from the lampholder.
MAINTENANCE
To avoid dust build up wipe lightly with
a damp cloth as required.
Clean the stainless steel at least 2 times
per year with a soft cloth and a neutral
detergent in order to avoid corrosion.
This amount should change to 4 times
per year in coastal and industrial areas.
Care should be taken when cleaning to
prevent scratching. A soft cloth or ne-
hair brush should be used together with
a non-abrasive cleaner.
Use soap or mild detergents and water
(preferably warm water) in order to clean
the nish on the surface of the stainless
Fig. 01
Lens Bezel
Lens Bezel
Clear Glass Lens
Bulb
(NOT SUPPLIED)
Silicone ‘O’ Ring
Bulb
(NOT SUPPLIED)
Silicone ‘O’ Ring
Lampholder
Dome Nut
(for securing to
Mounting Base)
Small ‘O’ Ring
Rubber
Seal
Mounting Base
Mounting
Base Cover
Mounting Threads
Terminals on inside rear of fitting
UP
DOWN
ACTIVE BROWN
To
Internal
Connection
To
House
Wiring
L
GREEN/YELLOW
BLUE
GREEN/YELLOW
NEUTRAL
EARTH
N
2
ARLEC ‘OBERON’ Stainless Steel Up/Down Wall Light ARLEC ‘OBERON’ Stainless Steel Up/Down Wall Light
3