Davey Q1003 Operating instructions

Category
Above ground pool accessories
Type
Operating instructions

This manual is also suitable for

Installation and
Operating Instructions
Models – Series 1000 Skim Filter
– SQ50/100 Skim Filter
– Wide Mouth Skim Filter
Skim Filters
Please pass these instructions on to the operator of this equipment.
The installation of this product should be carried out by a person knowledgable in
spa pool plumbing requirements following the Installation Instructions provided in
this manual.
WARNING: Failure to follow these instructions and comply with all applicable
codes may cause serious bodily injury and/or property damage.
NOTE: MULTIPLE PUMP SYSTEMS: Always ensure that a minimum of two suction
points are installed per pump.
This diagram provides Davey’s recommendation
for the safe installation of skim lters in spa pools.
Please refer to the applicable standards
within the market you operate.
WARNING: A secondary suction point is required in a skim lter installation to
prevent entrapment of hair and body.
Secondary
Suction
Point
Skim Filter
IN OUT
Shut off
valve
Equal diameter
pipe
Recommend no less
than 1 metre apart
Shut off
valve
Pump Heater
Return To
Spa Pool
Protective
Cover
Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517
Head Office and Manufacturing
6 Lakeview Drive,
Scoresby, Australia 3179
Ph: +61 3 9730 9222
Fax: +61 3 9753 4100
Website: davey.com.au
Customer Service Centre
Ph: 1300 2 DAVEY (1300 232 839)
Fax: 1300 304 850
E-mail: sales@davey.com.au
Interstate Offices
Sydney • Brisbane • Adelaide
Perth • Townsville
Davey Spa – New Zealand
2 Rothwell Avenue,
North Harbour, Auckland 0632
Ph: +64 9 415 8622
Fax: +64 9 415 8621
Website: spa-quip.co.nz
P/N Q916335-1 supersedes P/N Q916335
If the top cover plate of a Q1005 skim lter is removed, and the skimmer weir is fully
submerged, it will create suction at the top of the skimmer box. This could be hazardous to
persons in close proximity to the skim lter.
To overcome this potential hazard the top cover MUST be either permanently glued down or
covered by a lockable niche plate / cover to prevent removal of this lid.
Vent to atmosphere:
Compliance to AS 1926.3 - 2010 (Section 5.4 & 5.5)
The range of Davey Skim Filter models now include a vent screwed into the top of the lter. The
purpose of this vent is to provide a vacuum relief in the event the skimmer weir is fully submerged.
When the lter is tted, connect a rigid hose line (min 20mm in diameter) and run it to a suitable
location away from electrical equipment.
Note: A spa skim lter is designed to operate at a water level half way up the weir door. If the spa is
lled above this level, water may escape via the vent hose.
Top Cover Vent
Vent
Vent
Safety Notice – Q1005 Models
Compliance to AS 1926.3 – 2010 (Section 5.4 Child Resistant Lid)
Series 1000
(Q1005)
SQ50/100
(Q1240/Q1241)
Wide Mouth
(Q1200)
  • Page 1 1