DeLonghi Pinguino PAC CT90, PACCT90, Pinguino PAC CT110 Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the DeLonghi Pinguino PAC CT90 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
4
Important safeguards
DESCRIPTION
1 air outlet grille
2 control panel
3 castor wheels
4 handles
5 filter
6 air intake grille
7 air exhaust hose housing
8 drainage hose
9 power cable
10 wall flange
11 air exhaust hose
12 window outlet
13 castor locks
14 remote control
15 window bracket with locking pins
Use this appliance only as described in this instruction manual.
As with any electrical appliance, the instructions aim to cover as many situations as possible.
Caution and common sense should be used when operating and installing this air conditioner.
This appliance has been manufactured to cool and dehumidify domestic environments and
must not be used for other purposes.
It is dangerous to alter or modify the unit's characteristics in any way.
The appliance must be installed in accordance with the relevant national legislation.
Should repairs be necessary, contact the nearest authorized Repair Service Center. Unautho-
rized servicing can be dangerous.
The appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
In the case that the power cord becomes damaged, this must be repaired only by specialized per-
sonnel authorized by the manufacturer in order to protect against fire.
Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any doubts
check with a qualified electrician.
We strongly discourage the use of an extension cord due to potential safety hazards. For tem-
porary situations, use only CSA certified and UL listed 3-prong grounded extension cord,
attachment plug and connector, rated 15A, 125V
Before cleaning or maintenance operations, always unplug the unit from the outlet.
Do not pull on or place strain on the power cord when moving the appliance.
The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.
Do not rest hot or heavy objects on the appliance.
Clean the filters at least once a week.
Avoid using heaters near the unit.
The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie it horizontally.
Before transporting the unit, drain the unit. After transportation, wait at least 6 hours before switching the unit on.
The packaging materials can be recycled. You are therefore recommended to place them in
the special containers for differentiated waste collection.
This appliance is fitted with a special safety device. When the compressor switches off, this
device prevents it from switching on again for at least 3 minutes.
WARNING: Changes or modifications not expressly approved by the party responsible for com-
pliance could void the user's authority to operate the equipment.
.
SAVE THESE INSTRUCTIONS
THIS PRODUCT IS FOR HOUSEHOLD ONLY
5
GB
Setting up your portable
air conditioner
TO AVOID DAMAGE TO THE UNIT:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT
6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the unit has
been on its side, oil needs to return to the compressor to ensure proper function. Without allow-
ing the unit this time (6-24 hours) The unit may function for only a short time, and then the com-
pressor will break down from lack of oil.)
ELECTRICAL CONNECTIONS
Before plugging the appliance into the outlet, check that:
The outlet’s power supply corresponds to the value indicated on the rating label on the back
of the appliance;
The outlet and electrical circuit are adequate for the appliance;
The outlet is a 3-hole grounded outlet . If this is not the case, you must choose another outlet.
Failure to follow these important safety instructions absolves the manufacturer of all liability.
The instructions below will enable you to prepare your air conditioner for operation as efficiently
as possible. Before use, make sure the air intake and outlet grilles are unobstructed.
If it becomes necessary, the power cable must be replaced by a qualified professional only.
B
Other set-up methods:
Thanks to the locking pins, it’s possible to
use the window bracket also for sliding
windows. Position the hole of the bracket
so to allow a correct installation of the
exhaust hose (see figure C).
D
If you have a casement window (figure D)
follow steps 2 & 3 and place the window
outlet (12) outside the window to exhaust
the hot air.
For help with installation, operation, and
for all accessories and spare/replacement
parts, Please contact our toll free cus-
tomer service call center at:
1-800-322-3848 [US only]
Monday – Friday 8:30am – 5:00pm ET Or
log onto our website at
www.delonghiusa.com.
AIR CONDITIONING WITHOUT INSTALLATION
NOTE: Keep the air hoses as short and free of
curves as possible to avoid constrictions.
FOR OPTIMAL RESULTS SET-UP IN A DOU-
BLE-HUNG WINDOW:
1) Place the bracket in the window sill,
extend the bracket fully within the window
frame, fix the bracket by using the pin
then lower the window onto the bracket.
(Should the window bracket be too large
for the window. The plastic can be cut
with a saw by a qualified professional.)
2) Fit the air exhaust hose in the housing at
the back of the appliance. Insert it as
shown in figure A.
3) Connect the window outlet (12) to the
other end of the exhaust hose.
4) Insert the window outlet end of the exhau-
st hose into the slot of the window bracket
(fig. B).
1
2
A
C
134
5,27 in.
30 cm
11,8 inches
30 cm
11,8 inches
in the
window
pane
in the wall:
you are
recommended
to insulate the
section of wall
using suitable
insulation.
in the
wooden
kickboard
of a
French
window
F
Semi-permanent installation
SEMI-PERMANENT INSTALLATION
If required, your appliance can also be
installed semi-permanently (Fig. E).
Proceed as follows:
Drill a hole ø 5,25 inches (134 mm) in an
outside wall or through a window pane.
Respect the dimensions and height of the
hole given in figure F and G.
Fit the wall flange (10) into the hole.
Fit the air exhaust hose (11) in the rele-
vant housing located on the rear side of
the appliance. (fig. A page 5).
Fit the end of the hose (11) to the wall
flange (10) as shown in fig. G.
G
When the hose (11) is not connected, the dril-
led hole can be closed with the flange cap
(10).
NOTE: When installing the air conditioner
semi-permanently, you should leave a door
slightly open little as 1/2 “ (1 cm) to guar-
antee correct ventilation and room pressure.
6
E
Keep the air hoses as short and free of
curves as possible to avoid constrictions.
MAX100 cm
MAX 39,37 inches
MIN 35 cm
MAX 13,77 inches
“As special tools are required for installa-
tion, we suggest you have the applian-
ce installed by specialized personnel.”
7
Control panel
DESCRIPTION OF THE CONTROL PANEL
A ON/STAND-BY button
B MODE selection button:
Air conditioning, dehumidifying, fan.
C Fan speed selection button (HIGH/MED/LOW/AUTO)
D Timer button
E Programmed operation increase temperature/time button
F Programmed operation decrease temperature/time button
G Display Displays the temperature values set and the programmed operating time
H Timer in operation indicator light
I/L/M/N Fan speed lights and AUTO lights
O Fan mode light
P Dehumidifying mode light
Q Air conditioning mode light
R Remote control receiver
THE CONTROL PANEL
GB
Q
ABE
F
N
HRG
C
P
O
D
M
L
I
Never turn the air conditioner off by unplugging from the outlet. Always press the
button, then wait for a few minutes before unplugging. This allows the appliance to
perform a cycle of checks to verify operation.
8
Operation
TURNING THE APPLIANCE ON
Plug into an outlet.
Two lines appear on the display indicating that the appliance is in stand-
by.
Press the ON/STAND-BY button (A). When turned on, the air conditioner
starts operating in the same mode as when it was turned off.
Press the MODE button (B) until the light corresponding to the desired
mode lights up:
Light (Q) : air-conditioning mode
Light (P) : dehumidifying mode
Light (O) : fan mode
AIR CONDITIONING MODE
Ideal for hot muggy weather when you need to cool and dehumidify the
room.
To set this mode: press the + (E) or - (F) buttons until the desired tempe-
rature is displayed.
Then select the fan speed by pressing the button (C) until the light
corresponding to the required fan speed lights up:
MAXIMUM SPEED the air conditioner operates at maximum to
achieve the target temperature as rapidly as possible
MEDIUM SPEED reduces noise levels while maintaining a comfor-
table temperature
LOW SPEED for silent operation and maxium energy efficiency
AUTO: the appliance automatically selects the most suitable
fan speed in relation to the temperature set on the digital
display and current room temperature.
The most suitable temperature for the room during the summer varies from
75°F to 81°F (24 to 27°C). You are recommended, however, not to set a
temperature much below the outdoor temperature
DEHUMIDIFYING MODE
Ideal to reduce room humidity (spring and autumn, damp rooms, rainy
periods, etc). In dehumidifying mode, the appliance MUST be set-up in
the same way as for air conditioning, with the air exhaust hose attached
to enable the moisture to be discharged outside.
When the dehumidifying mode is selected, the light (P) comes on and
“ ” appears on the display.
At the same time, the AUTO fan light (N) comes on.
In this mode, fan speed is selected automatically by the appliance and
cannot be set manually.
FAN MODE
The unit operates without cooling or dehumidifying. This mode provides
ventilation only. When using the appliance in this mode, the air exhaust
hose does not need to be connected. Adjust fan speed by pressing the
button (C) as described for the air-conditioning mode.
In this mode, AUTO speed cannot be selected.
The fan speed selected will be displayed.
9
GB
Self-diagnosis
SETTING THE TIMER
The timer can be used to delay appliance start up or shutdown. This avoids wasting electricity by
not operating the appliance when it is not needed.
How to program delayed start up
Plug the appliance into an outlet and press the ON/STAND-BY button (A), then select the desi-
red operating mode and other settings (temperature, fan speed, etc).
Press the ON/STAND-BY button (A) again: The appliance switches to stand-by mode (the two
central segments are displayed).
Press the TIMER button (D). The last timer setting or the preset value 6.0 flashes on the display.
Use the + (E) or - (F) buttons to set the number of hours delay before the appliance comes on.
During the first ten hours, you can select half hour intervals. For times greater than ten hours,
one hour intervals can be selected. If the + (E) or - (F) buttons are pressed for more than 2
seconds, the time runs rapidly up to a maximum of 24 hours. Press the timer button again within
a few seconds to confirm the setting. If the setting is not confirmed within a few seconds, the
display resets to Stand-by. With the timer activated, the countdown before the programmed
start up time is displayed and the light (H) flashes.
To cancel the timer programming, press the timer button (D) again.
How to program delayed shutdown
Delayed shutdown can be programmed in any operating mode (air conditioning/dehumi-
difying/fan).
Press the TIMER button (D). The last timer setting or the preset value 6.0 flashes on the display.
Use the + (E) or - (F) button to set the number of hours delay before the appliance goes off.
During the first ten hours, you can select half hour intervals. For times greater than ten hours,
one hour intervals can be selected.
If the + (E) or - (F) buttons are pressed for more than 2 seconds, the time runs rapidly up to a
maximum of 24 hours.
Press the timer button again within a few seconds to confirm the setting.
When the timer is set, the light (H) flashes.
At the set time, the air conditioner shuts down and remains in stand-by.
To cancel the timer programming, press the timer button (D) again.
SELF-DIAGNOSIS
The appliance has a self diagnosis system to identify a number of malfunctions.
LOW TEMPERATURE
(frost prevention)
PROBE FAILURE
(sensor damaged)
FULL TANK
The appliance is fitted with a frost protection device to avoid
excessive formation of ice on internal components. The appliance
starts up again automatically when the defrosting process is com-
pleted
If this is displayed, contact your local authorized service centre.
Empty the internal tank, see page 14 "End of season operations"
IF ... IS DISPLAYED ...WHAT SHOULD YOU DO?
10
Using the remote control
MODELS WITH REMOTE CONTROL
Point the remote control at the receiver on
the air conditioner. The remote control
must be no more than 23 ft (7 metres)
away from the appliance (without obsta-
cles between the remote control and the
receiver)
The remote control must be handled with
extreme care. Do not drop it or expose it
to direct sunlight or sources of heat.
DESCRIPTION OF THE REMOTE CONTROL
16) Fan button
17) ON/STAND-BY button
18) Mode button
19) Timer button
20) Display
Replacing the batteries
Remove the cover on the rear of the
remote control;
Replace the old batteries with two new
R03 “AAA” 1.5V batteries, inserting them
correctly (see the instructions inside the
battery compartment);
Replace the cover.
20
16
17
19
18
If the remote control unit is replaced or discarded, the batteries must be removed and disposed
of in accordance with current legislation as they are harmful to the environment. Do not mix old
and new batteries.
Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries. Do not
dispose of batterias in fire. Batteries may explode or leak.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio com-
munications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired opera-
tion.
MAX 23 ft
MAX 7 metres
11
GB
Using the remote control
TURNING THE APPLIANCE ON
Plug into the outlet.
Press the ON/STAND-BY button (17) (when turned on, the air conditioner starts operating in the
same mode as when it was turned off).
Press the MODE button (18) to select the required mode:
AIR CONDITIONING ( )
DEHUMIDIFYING ( )
FAN ONLY ( )
An arrow on the display indicates the selected mode.
AIR CONDITIONING MODE ( )
Ideal for hot humid weather when you need to cool and dehumidify the room.
In air conditioning mode, use the buttons to select the desired temperature.
The display shows the set temperature.
To change the fan speed, use the fan button (16) on the remote control, choosing from the
available speeds:
the appliance automatically selects the most suitable fan speed in relation to the tem-
perature set on the digital display and current room temperature.
the air conditioner operates at maximum to reach the required temperature as rapidly as
possible.
reduces noise levels while maintaining a comfortable temperature.
for silent operation and maximum energy efficiency.
Two arrows on the display indicate respectively air-conditioning and the fan speed.
The most suitable temperature for the room during the summer varies from 24 to 27°C. You are
recommended, however, not to set a temperature much below the outdoor temperature.
DEHUMIDIFYING MODE ( )
Ideal to reduce room humidity (spring and autumn, damp rooms, rainy periods, etc).
In dehumidifying mode, the appliance selects fan speed automatically.
Two arrows on the remote control display indicate and respectively.
FAN MODE ONLY ( )
In fan mode, fan speed can be set by pressing the fan button (16).
The fan speed changes between the speeds available (LOW/MED/HIGH).
Two arrows on the display indicate the fan mode and the speed set.
In this mode, the auto speed cannot be selected.
SETTING THE TIMER
The timer can be used to delay appliance start up or shutdown. This avoids wasting electricity by
not operating the appliance when it is not needed.
How to program delayed shutdown
With the air conditioning unit on, press the timer button (19). The time is displayed and the
"h" symbol flashes, with a flashing arrow indicating timer shut-down .
Set the time when you want the appliance to go off using the buttons (from 30 minutes to
24 hours). During the first ten hours, you can select half hour intervals. For times greater than ten
hours, one hour intervals can be selected.
Press the timer button (19) again to confirm the selection. The appliance emits a beep and
the light (H) flashes on the control panel, confirming successful activation of the timer. A count-
down of the time left is displayed on the remote control display and the light (H) flashes on the
air conditioner display.
12
Using the remote control
At the end of the set time the appliance switches off automatically.
To cancel the timer programming, press the timer button (19) again. The appliance emits a
beep and both displays reset to display the settings prior to activation of the timer.
How to program delayed start up
With the air conditioner off, press the press the timer button (19) . An arrow indicating “timer
start-up” flashes on the display. Now make all the desired settings for when the applian-
ce will switch on (operating mode, fan speed and temperature). Confirm the settings by pres-
sing the timer button (19) . The time is displayed and the "h" symbol flashes.
Set the time when you want the appliance to switch off using the buttons (from 30 minutes
to 24 hours).
During the first ten hours, you can select half hour intervals. For times greater than ten hours,
one hour intervals can be selected.
Press the timer button (19) again to confirm the start-up time. A beep sounds and the time
set is also displayed on the control panel, confirming setting of the timer. The light (H) flashes
on the air conditioner display. A countdown of the time left is displayed on both displays.
At the end of the set time the appliance switches on automatically, with the settings made
previously.
To cancel the timer programming, press the timer button (19) again. The appliance emits
a beep and both displays reset to stand-by.
13
GB
To ensure optimal performance from your
portable air conditioner, follow these recom-
mendations:
close the windows and doors in the room
to be air conditioned.
The only exception is when the appliance
is installed through a hole in the wall.
In this case, you are recommended to
leave a slight draught through a door or
window to guarantee correct ventilation.
Protect the room from direct exposure to
the sun by partially closing curtains and/or
blinds to help the appliance run more effi-
ciently.
Tips
close doors and windows
close blinds or curtains
Never rest objects of any kind on the air
conditioner;
Never obstruct the air intake (6) or outlet
(1)
grilles;
Minimize the number of heat sources in
the room.
Never use the appliance in very damp
rooms (laundries for example).
Never use the appliance outdoors.
Make sure the air conditioner is on a level
floor. If necessary, place the two castor
locks (13) under the front wheels (3)
.
do not cover the appliance
14
Before cleaning or maintenance, turn the
appliance off by pressing the ON/STAND-BY
button then always unplug the appliance
from the outlet.
CLEANING THE SURFACE OF THE UNIT
You should clean the appliance with a slight-
ly damp cloth then dry with a dry cloth.
For safety reasons, never wash the air condi-
tioner with water. tioner with water.
Precautions
Never use petrol, alcohol or solvents to clean
the appliance. Never spray insecticide liquids
or similar products.
CLEANING THE AIR FILTERS
To keep your air conditioner working efficient-
ly, you should clean the dust filter every week
of operation.
The filter is housed in the intake grille.
To clean the filters, proceed as follows:
1. Remove the dust filter by extracting it
upwards (figure G).
2. Use a vacuum cleaner to remove dust
accumulations from the filter. If it is very
dirty, immerse in warm water and rinse a
number of times. The water should never
be hotter than 40°C. After washing, leave
the filter to dry, then put back in place.
START OF SEASON CHECKS
Make sure the power cable and plug are
undamaged and the outlet is in good condi-
tion. Follow the installation instructions pre-
cisely.
END OF SEASON OPERATIONS
To empty the internal circuit completely of
water, remove the cap (figure H).
Run off all water left into a basin. When all
the water has been drained, put the cap
back in place.
Clean the filter and dry thoroughly before
putting back.
Cleaning
G
H
15
GB
Troubleshooting
PROBLEM CAUSE REMEDY
The air
conditioning unit
does not start.
No electricity.
It is not plugged into the outlet.
The safety device of the plug has
tripped.
The internal safety device has tripped.
Restore electricity.
Plug into the outlet.
Reset the safety plug.
Wait 30 minutes, if the pro-
blem persists, contact your
service center.
The air
conditioning unit
works for a short
time only.
The air exhaust hose has a constriction.
The air exhaust hose is blocked.
There are tight bends in the air exhaust
hose.
Position the exhaust hose
correctly.
Check there are no
obstacles Obstructing air
discharge.
Eliminate the tight bends.
The air
conditioner
works, but does
not cool the
room.
Window open.
There are heat sources in the room
(lamps, etc.).
The exhaust hose is detached.
Air filters clogged.
Close the window.
Eliminate the heat source.
Connect the exhaust hose.
Clean or replace the filters.
Clean or replace the filter.
Bad odor in the
room.
The filter is clogged.
The air
conditioner does
not operate for
about 3 minutes
after turning it on.
The internal compressor safety device
prevents the appliance from being
restarted until three minutes have ela-
psed since it was last turned off.
Wait. This delay is part of
normal operation.
/ PF/
appears on the
display.
The appliance has a self diagnosis
system to identify a number of malfunc-
tions.
See the self-diagnosis chap-
ter.
NOTE:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS,
WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the
unit has been on its side, oil needs to return to the compressor to ensure proper function. With-
out allowing the unit this time (6-24 hours) The unit may function for only a short time, and then
the compressor will break down from lack of oil.)
TROUBLESHOOTINGng
16
Technical specifications
LIMIT CONDITIONS
Room temperature for
air conditioning 64 ÷ 95°F (18° ÷ 35°C)
TECHNICAL SPECIFICATION
Power supply voltage see rating label
Max. absorbed power
during air conditioning
Refrigerant
Cooling capacity
SAFETY PLUG
The appliance is fitted with a safety plug to protect the power cable.
If power is cut off, unplug from the outlet and make sure the power cable is undamaged.
If the cable is damaged, call the service center immediately.
If power cuts off frequently and the power cable is undamaged, contact a qualified elec-
trician.
OPERATION OF THE SAFETY PLUG
If the safety device incorporated in the plug trips and cuts off the power supply, check
that the power cable and plug are not damaged.
If the power cable is undamaged, to restore operation press the "RESET" button.
To verify correct operation of the plug, press the "TEST" button periodically and make sure
the appliance disconnects. If this is not the case, contact the service center.
To restore operation, press the "RESET" button.
Transport, filling, cleaning, recovery and dis-
posal of refrigerant should be performed by
a technical service centre appointed by the
manufacturer only.
The appliance should be disposed of by a
specialist centre appointed by the manu-
facturer only.
This appliance is equipped with a 3 prong grounded plug. The plug must be connected into
an outlet that is properly installed and grounded in the accordance with all local codes
and ordinances. Do not modify the plug provided with the appliance. If it will not fit the
outlet, have a proper outlet installed by a qualified electrician or relocate the unit to a pro-
per outlet.
If the household electrical supply does not meet the above specifications, or if you are not
sure your home has an effective electrical ground, have a qualified electrician or your local
electrical utility company check it and correct any problems.
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS
SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE
ON, 24 HOURS IS RECOMMENDED. (After the unit has been on its side,
oil needs to return to the compressor to ensure proper function.
Without allowing the unit this time (6-24 hours) The unit may function
for only a short time, and then the compressor will break down from
lack of oil).
17
GB
Limited Warranty
De’Longhi is the distributor of Kenwood home appliances.
This warranty applies to all home appliances with De’Longhi or Kenwood brand names.
FOR CONTIGUOUS UNITED STATES ONLY
Limited Warranty
We warrant each De’Longhi AIR CONDITIONER to be free from defects in material and workman-
ship. From the purchase date, our obligation under this warranty is to provide one (1) year free
parts and labor on the entire AIR CONDITIONER, with an additional four (4) years free on any part
of the sealed system consisting of the compressor, evaporator, condenser and factory connected
refrigerant tubing. Labor and all other parts during the additional four (4) year warranty are to be
paid by the owner. All AIR CONDITIONERS in need of repair are to be shipped to an authorized
De’Longhi service center at the owner’s expense, and De’Longhi will then incur the return ship-
ping costs. After the first five (5) years of ownership, all expenses (all parts, labor and shipping) are
to be paid by the owner of the unit. This warranty shall apply only if the AIR CONDITIONER is used
in accordance with the factory directions that accompany it, and on an Alternating Current (AC)
circuit. This warranty is in lieu of all other warranties and representations, expressed or implied, and
all other obligations or liabilities on our part. We do not authorize any other person or company
to assume for us any liability in connection with the sale or use of our AIR CONDITIONER. This war-
ranty shall not apply to any AIR CONDITIONER that has been repaired or altered outside our fac-
tory nor shall it apply to any AIR CONDITIONER that has been subjected to misuse, negligence or
accidents.
If repairs become necessary, see contact information below:
U.S. Residents:
For help with installation, operation, and for all accessories and spare/replacement parts,
Please contact our toll free customer service call center at
1-800-322-3848
Monday – Friday 8:30am – 5:00pm ET
or log onto our website at www.delonghiusa.com.
CANADA Residents:
Please contact our toll free hotline at 1-888-335-6644 or log onto our website at
www.delonghi.com.
Other countries:
Please visit: www.delonghi.com.
/