  • Hello! I am an AI chatbot trained to assist you with the DeLonghi PACAN125HPEKC1A Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
4
Important safeguard
• Use this appliance only as described in this
instructionmanual.
Aswithanyelectricalappliance,theinstructions
aim to cover as many situations as possible.
Cautionandcommonsenseshouldbeusedwhen
operatingandinstallingthisairconditioner.
• Thisappliancehas been manufacturedtocool
and dehumidify domestic environments and
mustnotbeusedforotherpurposes.
• It is dangerous to alter or modify the unit's
characteristicsinanyway.
• Theappliancemustbe installed in accordance
withtherelevantnationallegislation.
• Shouldrepairsbenecessary,contactthenearest
authorizedRepairServiceCenter.Unauthorized
servicingcanbedangerous.
• Theapplianceisnotintendedforusebypersons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they have
beengivensupervisionorinstructionconcerning
useoftheappliancebyapersonresponsiblefor
theirsafety.
Children should be supervised to ensure that
theydonotplaywiththeappliance.
• If the power cable is damaged, it must be
replacedbythemanufactureroranauthorized
technicalservicecentreinordertoavoidallrisk.
• Alwaysensuretheapplianceispluggedintoa
grounded3-prongoutlet.Ifyouhaveanydoubts
checkwithaqualiedelectrician.
• Donotuseextensioncables.
• Before cleaning or maintenance operations,
alwaysunplugtheunitfromtheoutlet.
• Donotpullonorplacestrainonthepowercord
whenmovingtheappliance.
• Theapplianceshouldnotbeinstalledwherethe
atmospheremaycontaincombustiblegases,oil
orsulphur,ornearheatsources.
• Donotresthotorheavyobjectsontheappliance.
• Cleantheltersatleastonceaweek.
• Avoidusingheatersneartheunit.
• The unit should be transported in a vertical
position.Ifthisisnotpossiblesecuretheunitat
anangle,donotlieithorizontally.
• Before transporting the unit, drain the unit.
Aftertransportation,waitatleast6hoursbefore
switchingtheuniton.
• The packaging materials can be recycled.You
are therefore recommended to place them in
the special containers for dierentiated waste
collection.
• This appliance is tted with a special safety
device.Whenthecompressorswitcheso,this
devicepreventsitfromswitchingonagainforat
least3minutes.
• WARNING: Changes or modications not
expresslyapprovedbythepartyresponsiblefor
compliance could void the user's authority to
operatetheequipment.
Specic warnings for appliances with R410A
refrigerant gas
R410ArefrigerantgasconformstoECregulationson
theenvironment.
Avoid perforating the refrigerant circuit of the
appliance.
ENVIRONMENTAL INFORMATION:
This unit contains uorinated greenhouse gases
coveredbytheKyotoProtocol.
Maintenance and disposal must be carried out by
qualiedpersonnelonly(R410A,GWP=1975).
Save these instructions
Thisproductisforhouseholdonly
5
INTRODUCTION
ThankyouforchoosingaDe’Longhiproduct.Pleasetakeafew
momentstoreadtheinstructionstoavoidrisksordamagetothe
appliance.
DESCRIPTION
Description of the appliance (see page 3 - Fig. A)
A1 airoutletgrille
A2 controlpanel
A3 handles
A4 castorwheels
A5 BioSilverlter
A6 airintakegrille
A7 airexhausthosehousing
A8 airintakegrille
A9 powercable
A10drainagehosewithcap
A11remotecontrolsignalreceiver
A12remotecontrolcompartment
Description of the accessories (see page 3 - Fig. B)
B1 wallangewithcap
B2 assembledairexhausthose
B3 windowoutlet
B4 windowbracketwithpins
B5 additionalwindowbracketwithpins
B6 waterdrainhosewithcap
B7 remotecontrol
B8 endofseasondustcover
B9 endofseasonaccessoriesbag
Electrical connection
Before plugging the appliance into the electrical receptacle,
checkthat:
• Theoutlets powersupplycorrespondsto thevalue indi-
catedontheratinglabelonthebackoftheappliance;
• Theoutletandelectricalcircuitareadequatefortheappli-
ance;
• Theoutletisa3-holegroundedoutlet .Ifthisisnot
thecase,youmustchooseanotheroutlet.Failuretofollow
theseimportantsafetyinstructionsabsolvesthemanufac-
turerofallliability.
If it becomes necessary, the power cable must be re-
placed by a qualied professional only.
Theinstructionsbelowwillenableyoutoprepareyouraircon-
ditionerforoperationasecientlyaspossible.Beforeuse,make
suretheairintakeandoutletgrillesareunobstructed.
USE
AIR CONDITIONING WITHOUT INSTALLATION
For optimal results set-up in a double-hung window:
1) Placethebracket inthe window sill,extendthe bracket
fullywithinthewindowframe,xthebracketbyusingthe
pinthenlowerthewindowontothebracket.(Shouldthe
windowbracketbetoolargeforthewindow.Theplastic
canbecutwithasawbyaqualiedprofessional.)
2) FittheairexhausthoseB2inthehousingatthebackofthe
appliance.Insertitasshowningure1.
3) ConnectthewindowoutletB3totheotherendoftheex-
hausthose.
4) Insertthewindowoutletendoftheexhausthoseintothe
slotofthewindowbracket(g.2).
Other set-up methods:
• Thankstothelockingpins,it’spossibletousethewindow
bracketalsoforslidingwindows.Positiontheholeofthe
bracketsotoallowacorrectinstallationoftheexhausthose
(seegure3).
1
2
6
• Ifyouhaveacasementwindow(gure4)followsteps2&
3andplacethewindowoutletB3outsidethewindowto
exhaustthehotair.
•
Ifthewindowsarelarge,usetheadditionalwindowbracket
B5
(ifprovided)tocoveryourwindowaperture,extendingit
totherequiredlength,thenblockingitwiththelockingpins
supplied(seegure5).Makesureyoudonotcoverthehole
forthewindowoutlet.
Forhelpwithinstallation,operation,andforall
accessoriesandspare/replacementparts,pleasecontact
ourtollfreecustomerservicecallcenterat:
1-800-322-3848[USonly]
1-888-335-6644[Canadaonly]
01-800-711-8805(Mexicoonly]
orlogontoourwebsiteat www.delonghi.com
SEMIPERMANENT INSTALLATION
If required, your appliance can also be installedsemi-perma-
nently(Fig.6).
min. 11,8 in
min. 30cm
min. 11,8 in
min. 30cm
Proceedasfollows:
• Drillaholeø5,25inches(134mm)inanoutsidewallor
through a window pane. Respect the dimensions and
heightoftheholegiveningure7and8.
134
Ø 5,25 in.
• FitthewallangeB1intothehole.
• FittheairexhausthoseB2 intherelevanthousinglocated
ontherearsideoftheappliance.(g.1).
• FittheendofthehoseB2 tothewallangeB1 asshownin
g.8.
• WhenthehoseB2isnotconnected,thedrilledholecanbe
closedwiththeangecapB1.
3
4
6
7
inthe
window
panel
inthewooden
kickboard
ofaFrench
window
inthewall:
youare
recommended
toinsulatethe
sectionofwall
usingsuitable
insulation.
1
3
2
5
7
MAX 39 in
MIN 14 in
NOTE: As special tools are required for installation, we
suggest you have the appliance installed by specialized
personnel.
NOTE: When installingthe air conditionersemi-permanently,
youshouldleaveadoorslightlyopenlittleas1/2“(1cm)to
guaranteecorrectventilationandroompressure.
NOTE:Keeptheairhosesasshortandfreeofcurvesaspossible
toavoidconstrictions.
8
DESCRIPTION OF THE CONTROL PANEL ( Fig. C)
C1 ON/STAND-BYbutton
C2 MODE selectionbutton(conditioning,dehumidifying,fan,
heating)
C3 Decreasetemperature/programmedoperationtimebutton
C4 Timerbutton
C5 Fanspeedselectionbutton(LOW/MED/HIGH/AUTO)
C6 Increasetemperature/programmedoperationtimebutton
C7 Air-conditioningsymbol
C8 Dehumidifyingsymbol
C9 Fansymbol
C10 Heatingsymbol
C11 Alarmsymbol
C12 Fanspeedindicator
C13 Timersymbol
C14 Settemperaturesymbol
C15 Timeindicator
C16Temperaturevalueset,programmeddelayedON/OFFtime
Note:
Afterfewsecondsofthecontrolpanelinactivity,itsbrightness
willbeautomaticallyreduced.
Wheninstand-byafterfewminutesitwillbefurtherreduced.
CONTROL PANEL
C1
C10
C2
C11C12
C14
C13C15
C3
C4
C8 C9
C6
C16
C7
C5
C
8
OPERATING FROM THE CONTROL PANEL
TURNING THE APPLIANCE ON/OFF
Before plugging the appliance check the cap on back of
the unit are correctly inserted on drainage hose A10.
Plugtheapplianceintotheelectricalreceptacle.Twolinesap-
pearonthedisplayindicatingthattheapplianceisinstand-by.
Press button(C1)toswitchtheapplianceon.
Whenturnedon,theairconditionerstartsoperatinginthesame
modeaswhenitwasturnedo.
Toturnotheappliance,pressthe button,thenunplugthe
appliance.
Note
:
Neverswitchotheappliancebyunpluggingit:always
pressthe button,waitafewminutesandthenunplug.Do-
ingso,theappliancewillrunacheckoftheoperatingconditions.
AIR CONDITIONING MODE
Idealforhotmuggyweatherwhenyouneedtocoolanddehu-
midifytheroom.Tosetthismode:
• Press repeatedly the MODE button (C2) until the
conditioning symbol is displayed: the display shows the
desiredtemperature.
• Press+(C6)or-(C3)buttonstoadjustthedesiredtem-
perature.
• Selectthefanspeedbypressingthe button(C5).
Youcanchoose:
Minimum speed:forsilentoperation.
Medium speed:reducesnoiselevelswhile main-
tainingacomfortabletemperature.
Maximum speed:toachievethetargettempera-
tureasrapidlyaspossible.
the appliance automatically selects the
mostsuitablefanspeedinrelationtothetemperaturesetonthe
digitaldisplayandcurrentroomtemperature.
The most suitable indoor temperature for the room during the
summer varies from 75°F to 81°F (24 to 27°C). You are recom-
mended, however, not to set a temperature much below the out-
door temperature.
DEHUMIDIFYING MODE
Ideal to reduce room humidity (spring and autumn, damp
rooms,rainyperiods,etc).In dehumidifyingmode,theappli-
ance MUSTbeset-upinthesame wayasforairconditioning,
withtheairexhausthose(B2)attachedtoenablethemoisture
tobedischargedoutside.Tosetthismode:
• PressrepeatedlytheMODE buttonuntilthedehumidifying
symbolisdisplayed.
FAN MODE
Whenusingthe appliancein thismode,theair exhausthose
(B2)doesnotneedtobeconnected.
Tosetthismode:
• PressrepeatedlytheMODE buttonuntilthefansymbolis
displayed.
• Selectthefanspeedbypressingthe button(C5).
Youcanchoose:
Minimum speed:forsilentoperation.
Medium speed:reducesnoiselevelsbutstillmain-
tainsagoodlevelofcomfort.
9
Maximum speed:formaximumfanpower.
HEATING MODE
Thisisidealinspringandautumnwhenoutdoortemperatures
arenotparticularlysevere.Forthismode,theapplianceshould
bepreparedinthesamewayasforairconditioning,withthe
airexhausthose(B2)attachedtoenablethemoisturetobedis-
chargedoutside.Tosetthismode:
• PressrepeatedlytheMODE buttonuntiltheheatingsym-
bolisdisplayed.
• Press+(C3)or-(C6)buttonstoadjustthedesiredtem-
perature.
Note:
• Inthismode,fanspeedisselectedautomaticallybytheap-
plianceandcannotbesetmanually.
• Whenoperatinginverycoldrooms,theappliancedefreez-
esautomatically,momentarilyinterruptingnormalopera-
tion.“Lt“appearsonthedisplay.Duringthisoperation,it
isnormalforthenoisemadebytheappliancetochange.
• Inthismode,youmayhavetowaitafewminutesbefore
theappliancestartsgivingouthotair.
• Inthismode,thefanmayoperateforshortperiods,even
thoughthesettemperaturehasalreadybeenreached.
• Itmayhappen thatthedisplayshows“HLalarm.Inthis
case,emptytheinternalsafetytankfollowingtheinstruc-
tionintheSection“EndofSeasonoperatons”.Attheend,
pressagainthe buttontorestoretheheatingfunction.
SETTING THE TIMER
Thetimercanbeusedtodelayappliancestartuporshutdown.
Thisavoidswasting electricity bynot operatingthe appliance
whenitisnotneeded.
How to program delayed start up
• Plugtheapplianceintotheelectricalreceptacleandturn
theunittostandby.
• Pressthetimerbutton(C4):thetimersymbol(C13)and
thenumberofhourscomeon.
• Usethe+(C6)or- (C3)buttonstosetthenumberofhours
delaybeforetheappliancecomeson.
• Afewsecondafterset,thesettingismemorised,thetimer
symbolislitandthedisplayshowsthattheapplianceisin
standby.
•
Theappli
ancewillstartworkingusingthemodepreviously
set.Theappliancecanbesettocomeonwithinthenext24
hours.
Todeletethesetting,presstwotimesthetimerbutton(C4).The
timersymbol(C13)switcheso.
How to program delayed shutdown
• Withtheairconditionieron,ineverymode,itispossibleto
setthedelayedshutdown.
• PresstheTimer(C4)button:thetimersymbol(C13)and
thehoursswitchon.
• Usethe+(C6)or- (C3)buttonstosetthenumberofhours
delaybeforetheapplianceturnso.Afewsecondafterset,
thesettingismemorised,thetimersymbolislitandthe
displayshowsthecurrentmode.
Attheendofthesettimetheapplianceautomaticallyturns
instandbymode.
Todeletethesetting,presstwotimesthetimerbutton(C4).The
timersymbol(C13)switcheso.
OPERATING FROM THE REMOTE CONTROL
USING THE REMOTE CONTROL
• Pointtheremotecontrolat thereceiver(A11)onthe air
conditioner.Theremotecontrolmustbenomorethan16
ft(5meters)awayfromtheappliance(withoutobstacles
betweentheremotecontrolandthereceiver).
• Theremotecontrolmustbehandledwithextremecare.Do
notdropitorexposeittodirectsunlightorsourcesofheat.

NOTE: Theremotecontrolcanbesafelystoredintheappropiate
compartmentA12(seegure).
MAX 16 ft
MAX 5 meters
10
DESCRIPTION OF THE REMOTE CONTROL FIG. D
D1) ON/STAND-BYbutton
D2) Increase/decreasetemperature/programmedoperation
D3) MODE”selectionbutton
D4) Fanspeedselectionbutton
D5) Switchbutton°C/°F
D6) TIMER button

INSERTING OR REPLACING THE BATTERIES
• Removethecoverontherearoftheremotecontrol;
• ReplacetheoldbatterieswithtwonewR03AAA1.5Vbat-
teries,insertingthemcorrectly(seetheinstructionsinside
thebatterycompartment);
• Replacethecover.
If the remote control unit is replaced or discarded, the batter-
ies must be removed and disposed of in accordance with cur-
rent legislation as they are harmful to the environment. Do not
mix old and new batteries.
Do not mix alkaline, standard (carbon-zinc) or rechargeable
(nickel-cadmium) batteries. Do not dispose of batteries in re.
Batteries may explode or leak. If the remote control is not be
used for a certain length of time, remove the batteries.
TURNING THE APPLIANCE ON
• Plugintotheelectricalreceptacle.
• Pressthe button(D1)(whenturnedon,theaircon-
ditionerstartsoperatinginthesamemodeaswhenitwas
turnedo).
• Toswitchtheapplianceo,pressbutton (D1),then
removetheplug.
NOTE: Neverswitch theapplianceo byremovingtheplug.
Alwaysswitchitobypushingonthe buttonand
waitingfewminutesbeforeremovingtheplug.Onlyinthis
waytheappliancewillperformthestandardcheckings.
FUNCTIONS SELECTION
Thecontrolsontheremotecontrolarethesameasthoseonthe
controlpaneloftheappliance(C).Youshouldthereforereferto
the instructions in the chapterOPERATINGFROMTHE CON-
TROLPANELtoselectthedesiredfunctions.PressbuttonD5
toswitchthetemperaturedisplayfrom°Cto°Fandviceversa.
Note:
• Thisequipmenthasbeentestedandfoundtocomplywith
thelimitsforaClassBdigitaldevice,pursuanttopart15of
theFCCRules.Theselimitsaredesignedtoprovidereason-
ableprotectionagainstharmfulinterferenceinaresiden-
tialinstallation.
• Thisequipmentgenerates,usesandcanradiateradiofre-
quencyenergyand,ifnotinstalledandusedinaccordance
withtheinstructions,maycauseharmfulinterferenceto
radio communications. However, there is no guarantee
thatinterferencewillnotoccurinaparticularinstallation.
Ifthisequipmentdoescauseharmfulinterferencetoradio
ortelevisionreception,whichcanbedeterminedbyturn-
ingtheequipmentoandon,theuserisencouragedtotry
tocorrecttheinterferencebyoneormoreofthefollowing
measures:
-Reorientorrelocatethereceivingantenna.
- Increase the separation between the equipment and
receiver.
- Connecttheequipmentintoanoutletonacircuitdier-
entfromthattowhichthereceiverisconnected.
- Consultthedealeroranexperiencedradio/TVtechnician
forhelp.
Changes ormodications notexpresslyapprovedby the
partyresponsibleforcompliancecouldvoidtheuser’sau-
thoritytooperatetheequipment.
• Thisdevicecomplies with Part 15 oftheFCCRules. Op-
erationissubjecttothefollowingtwoconditions:(1)this
device maynot cause harmful interference,and(2) this
device must accept any interference received, including
interferencethatmaycauseundesiredoperation.
• ThisClassBdigitalapparatuscomplieswithCanadianCAN
ICES-3(B)/NMB-3(B).
D1
D5
D2
D6
D4
D3
D2
D
11
SELFDIAGNOSIS
Theappliancehasaselfdiagnosissystemtoidentifyanumberofmalfunctions.
Errormessagesaredisplayedontheappliancedisplay.
IF ... IS DISPLAYED,
“LowTemperature”
(frostprevention)
..WHAT SHOULD I DO?
Theapplianceisttedwithafrostprotec-
tiondevicetoavoidexcessiveformationof
ice.The appliancestarts up againauto-
matically when the defrosting process is
completed.
IF ... IS DISPLAYED,
ProbeFailure
(Probedamaged)
..WHAT SHOULD I DO?
Ifthisisdisplayed,contactyourlocalau-
thorizedservicecenter.
IF ... IS DISPLAYED,
“HighLevel”
(Internaltrayfull)
..WHAT SHOULD I DO?
Empty theinternal safety tankfollowing
the instructions in the section “End of
season operations”. If HL alarm reoccurs
frequentely in Air Conditioning, Dehu-
midifyingorHeatingmode, contactyour
localauthorizedservicecenter.
TIPS FOR CORRECT USE
Toensureoptimalresultsfromyourairconditioner,followthese
recommendations:
• closethewindowsanddoorsintheroomtobeaircondi-
tioned.When installingtheair conditionersemi-perma-
nently,youshouldleaveadoorslightlyopen(aslittleas
1/2inch(1cm))toguaranteeproperventilation.
Closedoorsandwindows
• Neverusetheapplianceinverydamprooms(laundriesfor
example).
• Protecttheroomfromdirectexposuretothesunbypar-
tiallyclosingcurtainsand/orblindstomaketheappliance
muchmoreeconomicaltorun.
Closeblindsorcurtains
• Neverusetheapplianceoutdoors.
•
Makesuretherearenoheatsourcesintheroom.
• makesuretheairconditionerisstandingonalevelsurface.
donotcovertheappliance
• Neverrestobjectsofanykindontheairconditioner.
• Neverobstructtheairintakeoroutletgrilles.
12
CLEANING
Before cleaning or maintenance, turn the appliance o by
pressingthe button,thenunplugfromelectricalrecep-
tacle.
CLEANING THE CABINET
Youshouldcleantheappliancewithaslightlydampcloththen
drywithadrycloth.Forsafetyreasons,neverwashtheaircon-
ditionerwithwater.
Precautions
Never use petrol, alcohol or solvents to clean the appliance.
Neversprayinsecticideliquidsorsimilar.
CLEANING THE BIO SILVER AIR FILTER
Ifthelterisdirty,aircirculationiscompromisedandtheef-
ciency of the dehumidifying and air purifying functions de-
creases.
Itisthereforegoodpracticetocleanthelteratregularinter-
vals.Thefrequencydependsonthedurationandconditionsof
operation.
Iftheunitisusedconstantlyorsystematically,youarerecom-
mendedtocleanthelteronceaweek.
Thelterishousedintheintakegrille.
Tocleanthelter,extractasshowning.9.
Useavacuumcleanertoremovethedustcollectedonthelter.
Ifitisverydirty,immerseinwarmwaterandrinseanumber
oftimes.Thewatershouldneverbehotterthan104°F(40°C).
After washing the lter, allow it to dry completely before
repositioningit.
TheBioSilverlterhelpscapturedustandpollenandhelpsre-
ducethegrowthofbacteriaandmoldonthelter.
START OF SEASON CHECKS
Makesurethepowercableandplug areundamagedandthe
groundconnectionisecient.
Followtheinstallationinstructionsprecisely.
END OF SEASON OPERATIONS
Todrainallwaterfromthecircuit,removethecapA10fromthe
drainageonthebackoftheapplianceandallowthewaterto
drainoutintoabasin(g.10).
Tofacilitatethisoperation,atthestartoftheseason,it’spossi-
bletoapplythewaterdrainhosewithcapB6.
Inordertoproperlystoragetheapplianceattheendofthesea-
son,wesuggestyoucoveritwith thesuppliedendofseason
dustcoverB8andyouputtheaccessoriesintherelevant
endofseasonaccessoriesbagB9.
Whentheapplianceisempty,replacethecaps.
Cleanthelteranddrythoroughlybeforeputtingback.
TECHNICAL SPECIFICATIONS
Powersupplyvoltage seeratinglabel
Max.absorbedpower
duringairconditioning 
Refrigerant 
Coolingcapacity 
LIMIT CONDITIONS
Roomtemperatureforairconditioning
(withfansatmaximumspeed) 64÷104°F18÷40°C
10
9
13
Transport, lling, cleaning, recovery and disposal of
refrigerant should be performed by a technical service
centre appointed by the manufacturer only.
The appliance should be disposed of by a specialist centre
appointed by the manufacturer only.
TO AVOID DAMAGE TO THE UNIT:
NEVERTRANSPORTORTURNTHEAPPLIANCEUPSIDEDOWNOR
ONITSSIDE.IFTHISOCCURS,WAIT6 HOURSBEFORETURNING
THEAPPLIANCEON,24HOURSISRECOMMENDED.Aftertheunit
hasbeenonitsside,oilneedstoreturntothecompressortoen-
sureproperfunction.Withoutallowingtheunitthistime(6-24
hours)theunitmayfunctionforonlyashorttime,andthenthe
compressorwillbreakdownfromlackofoil.
ELECTRICAL CONNECTION
Thisapplianceisequippedwitha3pronggroundedplug.The
plugmustbeconnectedintoanoutletthatisproperlyinstalled
andgroundedintheaccordancewithalllocalcodesandordi-
nances.Donot modify the plug providedwith the appliance.
Ifit willnottthe outlet,havea properoutlet installed bya
qualiedelectricianorrelocatetheunittoaproperoutlet.Ifthe
householdelectricalsupplydoesnotmeettheabovespecica-
tions,orifyouarenotsureyourhomehasaneectiveelectrical
ground,haveaqualiedelectricianoryourlocalelectricalutility
companycheckitandcorrectanyproblems.
SAFETY PLUG
Theapplianceisttedwithasafetyplugtoprotectthepower
cable.
Ifpoweriscuto,unplug fromtheoutletandmakesurethe
powercableisundamaged.
Ifthecableisdamaged,calltheservicecenterimmediately.
Ifpowercutsofrequentlyandthepowercableisundamaged,
contactaqualiedelectrician.
OPERATION OF THE SAFETY PLUG
Ifthesafetydeviceincorporatedintheplugtripsand cutso
thepowersupply,checkthatthepowercableandplugarenot
damaged.
Ifthepowercableisundamaged,torestoreoperationpressthe
"RESET"button.
Toverifycorrectoperationoftheplug,pressthe"TEST"button
periodicallyandmakesuretheappliancedisconnects.Ifthisis
notthecase,contacttheservicecenter.
Torestoreoperation,pressthe"RESET"button.
14
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Theairconditionerdoesnotcomeon itisnotpluggedintotheelectrical
receptacle
plugintotheelectrical
receptacle
thereisnocurrent wait
theinternalsafetydevicehastripped calltheServiceCenter
Theairconditionerworksforashort
timeonly
therearebendsorkinksintheair
exhausthose
positiontheairhosecorrectly,keepingit
asshortandfreeofcurvesaspossibleto
avoidbottlenecks
somethingispreventingtheairfrom
beingdischarged
checkandremoveanyobstacles
obstructingairdischarge
Theairconditionerworks,butdoesnot
cooltheroom
windows,doorsand/orcurtainsopened closedoors,windowsandcurtains,
bearinginmindtheTIPSFORCORRECT
USEgivenpreviously
thereareheatsourcesintheroom(oven,
hairdryer,etc)
eliminatetheheatsources
theairexhausthoseisdetachedfrom
theappliance
ttheairexhausthoseinthehousingat
thebackoftheappliance(g.1).
lterclogged cleanorreplacethelteraspreviously
described
thetechnicalspecicationofthe
applianceisnotadequatefortheroom
inwhichitislocated.
Duringoperation,thereisanunpleasant
smellintheroom
thelterisclogged cleantheltersaspreviouslydescribed
Theairconditionerdoesnotoperatefor
aboutthreeminutesafterrestartingit
preventstheappliancefrombeing
restarteduntilthreeminuteshave
elapsedsinceitwaslastturnedo
wait.Thisdelayispartofnormal
operation.
Thesymbol andoneofthe
followingmessages:HL/PF apperon
thedisplay
theappliancehasaselfdiagnosissystem
toidentifyanumberofmalfunctions.
seetheSELF-DIAGNOSISchapter
15
De’LonghiisthedistributorofKenwoodhomeappliances.
This warranty applies to all home appliances with De’Longhi or Kenwood brand names
LIMITED WARRANTY
WewarranteachDe’LonghiAIRCONDITIONERtobefreefromdefectsinmaterialandworkmanship.Fromthepurchasedate,our
obligationunderthiswarrantyistoprovidetwo(2)yearfreepartsandlaborontheentireAIRCONDITIONER,withanadditionalfour
(4)yearsfreeonanypartofthesealedsystemconsistingofthecompressor,evaporator,condenserandfactoryconnectedrefrigerant
tubing.Laborandallotherpartsduringtheadditionalfour(4)yearwarrantyaretobepaidbytheowner.AllAIRCONDITIONERSin
needofrepairaretobeshippedtoanauthorizedDe’Longhiservicecenterattheowner’sexpense,andDe’Longhiwillthenincurthe
returnshippingcosts.Aftertherstsix(6)yearsofownership,allexpenses(allparts,laborandshipping)aretobepaidbytheowner
oftheunit.ThiswarrantyshallapplyonlyiftheAIRCONDITIONERisusedinaccordancewiththefactorydirectionsthataccompanyit,
andonanAlternatingCurrent(AC)circuit.Thiswarrantyisinlieuofallotherwarrantiesandrepresentations,expressedorimplied,
andallotherobligationsorliabilitiesonourpart.Wedonotauthorizeanyotherpersonorcompanytoassumeforusanyliabilityin
connectionwiththesaleoruseofourAIRCONDITIONER.ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired
oralteredoutsideourfactorynorshallitapplytoanyAIRCONDITIONERthathasbeensubjectedtomisuse,negligenceoraccidents.
Ifrepairsbecomenecessary,seecontactinformationbelow:
U.S. Residents:
Pleasecontactourtollfreehotlineat 1-800-322-3848
orlogontoourwebsiteatwww.delonghi.com
CANADA Residents:
Pleasecontactourtollfreehotlineat1-888-335-6644
orlogontoourwebsiteatwww.delonghi.com
MEXICO Residents:
Pleasecontactourtollfreehotlineat01-800-711-8805
orlogontoourwebsiteatwww.delonghi.com
Theabovewarrantyisinlieuofallotherexpresswarrantiesandrepresentations.Allimplied
warrantiesarelimitedtotheapplicablewarrantyperiodsetforthabove.Thislimitationdoesnotapplyifyouenterintoanextended
warrantywith De’Longhi.Somestates/countriesdo not allow limitations on how long an implied warranty lasts, so the above
exclusionsmaynotapplytoyou.De’Longhidoesnotauthorizeanyotherpersonorcompanytoassumeforitanyliabilityin
connectionwiththesaleoruseofitsappliance.
How does country law apply?
Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrights,whichvaryfromstatetostate/countrytocountry.
/