White Rodgers 1F87-251 User manual

Category
Thermostats
Type
User manual

This manual is also suitable for

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II (current limited) cir-
cuits per the NEC code. Failure to do so may cause a
fire hazard.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers 7-Day Digital Thermostat uses the
technology of a solid-state microcomputer to provide precise
time/temperature control. This thermostat offers you the flexibil-
ity to design heating and cooling programs that fit your needs.
Features:
Separate program for each day of the week with four separate
time/temperature settings per day
Simultaneous heat and cool program storage
Preprogrammed temperature control
LCD continuously displays setpoint, and alternately dis-
plays time and room temperature
Backlit display
Temperature override until next program period
Manual program override (HOLD temperature)
°F/°C convertibility
Temperature range 45° to 90°F
RC, RH, W, Y, G , O and B terminals
B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
Program storage in case of power loss.
Battery powered (2 "AA" Energizer
®
alkaline batteries in-
cluded)
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
APPLICATIONS
For use with:
Standard heat/cool or heat only systems
Electric heat systems
Gas or oil fired systems
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
Hydronic (hot water or steam) systems
Single-stage heat pump systems (no auxiliary heat)
Millivolt systems
DO NOT USE WITH:
Multi-stage systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
1F87-251
Programmable Electronic Digital Thermostat
PART NO. 37-6417C
Replaces 37-6417B
0441
WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com
INSTALLATION AND
OPERATION INSTRUCTIONS
PRECAUTIONS
CAUTION
!
This thermostat is intended for use with a low voltage system;
do not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
WARNING
!
Operator: Save these instructions for future use!
2
INSTALLATION
REMOVE OLD THERMOSTAT
1. Shut off electricity at the main fuse box until installation is
complete. Ensure that electrical power is disconnected.
2. Remove the front cover of the old thermostat. With wires
still attached, remove wall plate from the wall. If the old
thermostat has a wall mounting plate, remove the thermostat
and the wall mounting plate as an assembly.
3. Identify each wire attached to the old thermostat using
the labels enclosed with the new thermostat.
4. Disconnect the wires from old thermostat one at a time. DO
NOT LET WIRES FALL BACK INTO THE WALL.
5. Install new thermostat using the following procedures.
ATTENTION!
This product does not contain mercury. However, this product
may replace a unit which contains mercury.
Do not open mercury cells. If a cell becomes damaged, do not
touch any spilled mercury. Wearing nonabsorbent gloves, take
up the spilled mercury with sand or other absorbent material and
place into a container which can be sealed. If a cell becomes
damaged, the unit should be discarded.
Mercury must not be discarded in household trash. When the
unit this product is replacing is to be discarded, place in a
suitable container and return to White-Rodgers at 2895 Harrison
Street, Batesville, AR, 72501-2117 for proper disposal.
ELECTRIC HEAT OR SINGLE-STAGE
HEAT PUMP SYSTEMS
This thermostat is configured from the factory to operate a heat/
cool, fossil fuel (gas, oil, etc.), forced air system. It is configured
correctly for any system that DOES NOT require the thermostat
to energize the fan on a call for heat. If your system is an electric
heat or heat-pump system that REQUIRES the thermostat to
turn on the fan on a call for heat, locate the ELECTRIC/GAS
switch on the back of the thermostat (see fig. 1) and switch it to
the ELECTRIC position. This will allow the thermostat to ener-
gize the fan immediately on a call for heat. If you are unsure if
the heating/cooling system requires the thermostat to control
the fan, contact a qualified heating and air conditioning service
person.
ATTACH THERMOSTAT BASE TO WALL
1. Remove the packing material from the thermostat. Gently
pull the cover straight off the base. Forcing or prying on the
thermostat will cause damage to the unit. If necessary, move
the electric heat switch (see ELECTRIC HEAT SYSTEMS,
above).
2. Connect wires beneath terminal screws on base using
appropriate wiring schematic (see figs. 2 through 7).
3. Place base over hole in wall and mark mounting hole
locations on wall using base as a template.
4. Move base out of the way. Drill mounting holes.
5. Fasten base loosely to wall, as shown in fig. 1, using two
mounting screws. Place a level against bottom of base,
adjust until level, and then tighten screws. (Leveling is for
appearance only and will not affect thermostat operation.) If
you are using existing mounting holes, or if holes drilled are
too large and do not allow you to tighten base snugly, use
plastic screw anchors to secure subbase.
6. Push excess wire into wall and plug hole with a fire-resistant
material (such as fiberglass insulation) to prevent drafts from
affecting thermostat operation.
BATTERY LOCATION
2 "AA" alkaline batteries are included in the thermostat at the
factory with a battery tag to prevent power drainage. You must
remove the battery tag to engage the batteries.
If "LO BATT" is displayed, the batteries are low and should be
replaced with fresh "AA" Energizer
®
alkaline batteries. To re-
place batteries, install the batteries along the top of the base
(see Fig. 1). The batteries must be installed with the positive (+)
end to the left.
HYDRONIC (HOT WATER OR STEAM)
HEATING SYSTEMS
This thermostat is set to operate properly with a forced-air
heating system. If you have a hydronic heating system (a system
that heats with hot water or steam), you must set the thermostat
to operate properly with your system. Change the second option
in the configuration menu to SL (see CONFIGURATION MENU,
page 4).
CHECK THERMOSTAT OPERATION
If at any time during testing your system does not operate
properly, contact a qualified service person.
Turn on power to the system.
Fan Operation
If your system does not have a G terminal connection, skip to
Heating System.
1. Move FAN switch to ON position. The blower should begin
to operate.
2. Move FAN switch to AUTO position. The blower should stop
immediately.
Mounting
holes
Mounting
holes
Electric/Gas
switch
Screw anchors
Figure 1. Thermostat Base
3
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Figure 5. Typical wiring diagram for
heat/cool, 5-wire, two-transformer systems
HEATING TRANSFORMER
(Class II Current Limited)
Heating
System
Fan
Relay
Cooling
System
RC
24 VAC
120 VAC
Hot
Neutral
COOLING TRANSFORMER
(Class II Current Limited)
OB
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Figure 4. Typical wiring diagram for
heat/cool, 4-wire, single transformer systems
Heating
System
Fan
Relay
Cooling
System
RC
JUMPER
WIRE
OB
RED jumper wire (provided with thermostat) must be
connected between thermostat RH and RC terminals
for proper thermostat operation with this system.
NOTE
TRANSFORMER
(Class II Current Limited)
RH
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Figure 2. Typical wiring diagram for
heat only, 3-wire, single transformer systems
TRANSFORMER
(Class II Current Limited)
Heating
System
Fan
Relay
Y
RC
JUMPER
WIRE
OB
For 2-wire Heat only,
attach to RH and W
NOTE
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Figure 7. Typical wiring diagram for heat pump
with reversing valve energized in HEAT
Reversing
Valve*
RCOB
JUMPER
WIRE
Compressor
Contactor
JUMPER
WIRE
* Reversing valve is energized when the
system switch is in the HEAT position
Fan
Relay
TRANSFORMER
(Class II Current Limited)
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Figure 3. Typical wiring diagram for
cool only, 3-wire, single transformer systems
Cooling
System
Fan
Relay
RCOB
JUMPER
WIRE
TRANSFORMER
(Class II Current Limited)
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G W
Figure 6. Typical wiring diagram for heat pump
with reversing valve energized in COOL
Reversing
Valve*
RCOB
JUMPER
WIRE
Compressor
Contactor
JUMPER
WIRE
* Reversing valve is energized when the
system switch is in the COOL position
Fan
Relay
TRANSFORMER
(Class II Current Limited)
Heating System
1. Move SYSTEM switch to HEAT position. If the heating
system has a standing pilot, be sure to light it.
2. Press to adjust thermostat setting above room tempera-
ture. The heating system should begin to operate.
3. Press
to adjust temperature setting below room tem-
perature. The heating system should stop operating.
CAUTION
!
Cooling System
To prevent compressor and/or property damage, if the
outdoor temperature is below 50°F, DO NOT operate
the cooling system.
1. Move SYSTEM switch to COOL position.
2. Press
to adjust thermostat setting below room tem-
perature. The blower should come on immediately on high
speed, followed by cold air circulation
3. Press to adjust temperature setting above room tem-
perature. The cooling system should stop operating.
4
Press HOLD to change to the next menu item or press TIME to
go backwards to the previous item in the menu. To exit the menu
and return to the program operation, press RUN. If no keys are
pressed within fifteen minutes, the thermostat will revert to
normal operation.
1) Select FA or SL (Fast or Slow) Heating Cycle Rate - The
FA setting is frequently used for gas, oil or electric heat. The
SL setting produces a longer heating cycle which is nor-
mally for hot water or steam (hydronic) systems. Both
settings produce very accurate temperature control and
can be set to your personal preference. FA cycles the
system just under 1°F and the SL setting cycles at approxi-
mately 1.5°F.
2) Select backlit display - The display backlight improves
display contrast in low lighting conditions. Selecting back-
light ON will keep the light on for a short period of time after
any key is pressed. Selecting OFF will keep the light off.
3) Select Energy Management Recovery OFF or ON -
Energy Management Recovery (EMR) causes the thermo-
stat to start heating or cooling early to make the building
temperature reach the program setpoint at the time you
specify. Heating will start 5 minutes early for every 1° of
temperature required to reach setpoint.
Example: You select EMR and have your heating pro-
grammed to 65° at night and 70° at 7 AM. If the building
temperature is 65° the difference between 65° and 70° is 5°.
Allowing 5 minutes per degree the thermostat setpoint will
change to 70° at 6:35 AM. Cooling allows more time per
degree because it takes longer to reach temperature.
4) Select filter replacement run time - The thermostat will
display "FLTR" after a set time of operation. This is a
reminder to change or clean your air filter. This time can be
set from 0 to 1950 hours in 50 hour increments. A selection
of 000 will cancel this feature. When "FLTR" is displayed,
you can clear it by pressing HOLD and RUN at the same
time. This resets the timer and starts counting the hours
until the next filter change. Changing the time in the menu
also resets the timer.
Before you begin programming your thermostat, you should be
familiar with its features and with the display and the location and
operation of the thermostat buttons. Your thermostat consists of
two parts: the thermostat cover and the base. To remove the
cover, pull it straight out from the base. To replace the cover, line
up the cover with the base and press until the cover snaps onto
the base.
The Thermostat Buttons and Switches
1
Raises temperature setting.
2
Lowers temperature setting.
3
TIME button.
4
PRGM (program) button.
5
RUN (run program) button.
6
HOLD temperature button.
7
FAN switch (ON, AUTO).
8
SYSTEM switch (COOL, OFF, HEAT).
The Display
9
Indicates day of the week.
10
Flame icon ( ) is displayed when the SYSTEM switch is in
the HEAT position. Snowflake icon (
)is displayed (non-
flashing) when the SYSTEM switch is in the COOL position.
Snowflake is displayed (flashing) if the thermostat is in
lockout mode to prevent the compressor from cycling too
quickly.
11
Displays "LO BATT" when the 2 "AA" batteries are low and
should be replaced. Nothing else will be displayed.
12
Alternately displays current time and temperature. Displays
"LO" in the minutes field when batteries are low.
13
The word "HOLD" is displayed when the thermostat is in
the HOLD mode.
14
Displays currently programmed set temperature (this is
blank when SYSTEM switch is in the OFF position).
15
Displays "FLTR" when the system has run for the pro-
grammed filter time period as a reminder to change or clean
your air filter.
CONFIGURATION MENU
The configuration menu allows you to set certain thermostat
operating characteristics to your system or personal require-
ments.
Press RUN to make sure the thermostat is in the run program
mode, then press PRGM and RUN at the same time to enter the
configuration menu. The display will show the first item in the
configuration menu.
The configuration menu table summarizes the configuration
options. An explanation of each option follows.
2
1
3 4 5 6 7
8
10 1315 11
14
1012 12
9
9
Figure 8. Thermostat display, buttons, and switches
SU
BATTHOLD
PM
SA
FLTR
AM
MO TU WE TH FR
TIME PRGM RUN HOLD
Fltr
FAN SYSTEM
ON AUTO COOL OFF HEAT
OPERATION
5
5) Select Compressor Lockout LOC OFF or ON - Selecting
LOC ON will cause the thermostat to wait 5 minutes before
turning on the compressor if the heating and cooling system
loses power. It will also wait 5 minutes minimum between
cooling cycles. This is intended to help protect the compres-
sor from short cycling. Some newer compressors already
have a time delay built in and do not require this feature.
Your compressor manufacturer can tell you if the feature is
already present in their system. When the compressor time
delay occurs it will flash the (snowflake icon) for about five
minutes then turn on the compressor.
6) Select Temperature Display Adjustment 4 LO to 4 HI -
Allows you to adjust the room temperature display 4° higher
or lower. Your thermostat was accurately calibrated at the
factory but you have the option to change the display
temperature to match your previous thermostat.
7) Select F° or C° Readout - Changes the display readout to
Centigrade or Fahrenheit as required.
OPERATING FEATURES
Now that you are familiar with the thermostat buttons and
display, read the following information to learn about the many
features of the thermostat.
SIMULTANEOUS HEATING/COOLING PROGRAM
STORAGE When programming, you can enter both your
heating and cooling programs at the same time. There is no
need to reprogram the thermostat at the beginning of each
season.
TEMPERATURE OVERRIDE Press
or until the
display shows the temperature you want. The thermostat
will override current programming and keep the room
temperature at the selected temperature until the next
program period begins. Then the thermostat will automati-
cally revert to the program.
HOLD TEMPERATURE The thermostat can hold any
temperature within its range for an indefinite period without
reverting to the programmed temperature. Momentarily
press HOLD button. "HOLD" will be displayed. Then choose
1
Step Press Button(s) Displayed (Factory Default) Press or to select: COMMENTS
2
(FA)
SL
4
5
E
(ON)
OFF
6
7
LOC
(OFF)
ON
0 HI
(0)
4 LO to
4 HI
(F) C
Returns to normal operation
8
Select Energy Management Recovery OFF or ON
Select Compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to F or C
RUN
PRGM
and RUN
HOLD
*
HOLD
*
3
d-L
(ON)
OFF
Select display backlight OFF or ON
HOLD
*
HOLD
*
Filter
(000)
0 to 1950 hours
(in 50 hour increments)
Select filter replacement run time
HOLD
*
HOLD
*
Select FA or SL (Fast or Slow) heating cycle rate
Configuration Menu
* Press
HOLD to advance to next item or TIME to move backwards to previous item
the desired temperature by pressing or . The
thermostat will hold the room temperature at the selected
setting until you press RUN button to start program opera-
tion again.
LOW BATTERY INDICATORIf the 2 AA alkaline bat-
teries are low and should be replaced, the display will be
blank except for LO BATT. When the batteries are low,
pressing any button will cause the display to operate for ten
seconds. After ten seconds, the display will be blank except
for LO BATT. You cannot program with low batteries, but
you can override setpoint temperature. After LO BATT
has been displayed for 4 weeks, the thermostat will raise
the temperature 10 degrees above your setpoint on COOL
mode and will drop temperature 10 degrees below your
setpoint on HEAT mode.
SIMPLIFIED COPY DAY FUNCTION This feature al-
lows Monday's program to be copied into the rest of the
week's programming. This feature is available the first
time you program your thermostat. To use this feature,
simply enter the program for Monday as described in
PROGRAMMING YOUR THERMOSTAT, and then press
RUN or HOLD. The only way to restore this feature is to
complete a software reset (see Reset Operation under
TROUBLESHOOTING section).
COPY DAY FUNCTION This feature allows a selected
day's program to be copied to the desired day's program-
ming. To use this feature: in PRGM mode, select the day
to be copied
from by pressing the HOLD button. Enter the
program for the selected day as described in PROGRAM-
MING YOUR THERMOSTAT. Press and hold the TIME
button for 4 seconds to begin the Copy mode. The LCD will
display "COPY" and the selected day to be copied. The
day the program will copy to will be flashing. Press the
HOLD button to select the day you want to copy to. Press
TIME to complete the Copy Day operation and return to
PRGM mode. Press RUN to exit.
6
PROGRAMMING YOUR THERMOSTAT
This section will help you plan your thermostats program to
meet your needs. For maximum comfort and efficiency, keep the
following guidelines in mind when planning your program.
When heating (cooling) your building, program the tem-
peratures to be cooler (warmer) when the building is vacant
or during periods of low activity.
During early morning hours, the need for cooling is usually
minimal.
Planning Your Program
Look at the factory preprogrammed times and temperatures
shown in the sample schedule. If this program will suit your
needs, simply press the RUN button to begin running the factory
preset program.
If you want to change the preprogrammed times and tempera-
tures, follow these steps.
Determine the time periods and temperatures for your week-
day and weekend programs. You must program four periods
for each day program. However, you may use the same heating
and cooling temperatures for consecutive time periods. You
can choose start times, heating temperatures, and cooling
temperatures independently for each day programs (for ex-
ample, you may select 5:00 AM and 70° as the Monday 1st
period heating start time and temperature, and also choose
7:00 AM and 76° as the Monday 1st period cooling start time
and temperature).
Use the following table to plan your program time periods and
the temperatures you want during each period. Fill in the
complete table to have a record of your programs.
Entering Your Program
Follow these steps to enter the heating and cooling programs
you have selected.
Set Current Time and Day
1. Press TIME button once. The display will show the hour only.
EXAMPLE:
PM
2. Press and hold either or until you reach the correct
hour and AM/PM designation (AM begins at midnight; PM
begins at noon).
3. Press TIME once. The display window will show the minutes
only.
EXAMPLE:
4. Press and hold either or until you reach the correct
minutes.
5. Press TIME once. The display will show the day of the week.
6. Press
or until you reach the current day of the week.
7. Press RUN once. The display will show the correct time and
room temperature alternately.
Enter Heating Program
1. Move the SYSTEM switch to HEAT.
2. Press PRGM once. MO (indicating Monday program) will
appear in the display. Also displayed are the currently
programmed start time for the 1st heating period and the
currently programmed temperature (flashing).
EXAMPLE:
AM
MO
This display window shows that for Monday's 1st heating
period, the start time is 6:00 AM, and 70° is the programmed
temperature (this example reflects factory preprogramming).
3. Press
or to change the displayed temperature to
your selected temperature for Monday's 1st heating program
period.
4. Press TIME once (the programmed time will flash). Press
or until your selected start time for Monday's 1st
heating program period appears. The time will change in 15
minute increments. When your selected time is displayed,
press TIME again to return to the change temperature mode.
PERIOD 1
Time Temp Time Temp
Heating/Cooling Schedule Plan
Mon
Tues
Wed
Thur
Fri
Sat
Sun
HEAT COOL
PERIOD 2
Time Temp Time Temp
HEAT COOL
PERIOD 3
Time Temp Time Temp
HEAT COOL
PERIOD 4
Time Temp Time Temp
HEAT COOL
1ST
2ND
3RD
4TH
1ST
2ND
3RD
4TH
SAMPLE
Heating/Cooling Schedule Plan (Factory Program)
6:00 AM
8:00 AM
5:00 PM
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
70° F
62° F
70° F
62° F
78° F
85° F
78° F
82° F
ALL DAYS OF THE WEEK
Start Time Temperature
Period
COOL HEAT
7
5. Press PRGM once. The currently programmed start time
and setpoint temperature for the Monday's 2nd heating
program period will appear.
6. Repeat steps 3 and 4 to select the start time and heating
temperature for Monday's 2nd heating program period.
7. Repeat steps 3 through 5 for the 3rd and 4th heating program
periods. Monday heating programs are now complete.
NOTE
If you are programming your thermostat for the first time and you
want programming for all days of the week to be the same as
Monday's program, press RUN or HOLD at this point, and
proceed to Enter Cooling Program. (This simplified COPY
DAY feature only works the first time you program your thermo-
stat. If you want to copy one day's programming to a specific day
programming, refer to COPY DAY FUNCTION in OPERATING
FEATURES. If you are changing your thermostat's program-
ming, you must program each day separately.)
8. Press HOLD once. TU (indicating Tuesday program) will
appear in the display, along with the start time for the 1st
heating period and the currently programmed temperature.
9. Repeat steps 3 through 7 to complete Tuesday's heating
programming.
10.Continue entering each day's programming until all heating
periods time and temperatures have been entered.
11.When you have completed entering your heating program,
press RUN.
Enter Cooling Program
If the outside temperature is below 50°F, disconnect
power to the cooling system before programming.
Energizing the air conditioner compressor during
cold weather may cause personal injury or property
damage.
1. Move SYSTEM switch to COOL position.
2. Follow the procedure for entering your cooling program,
using your selected cooling times and temperatures.
CHECK YOUR PROGRAMMING
Follow these steps to check your thermostat programming one
final time before beginning thermostat operation.
1. Move SYSTEM switch to HEAT position.
2. Press PRGM to view the 1st Monday heating period time and
temperature. Each time you press PRGM, the next heating
period time and temperature will be displayed in sequence
for Monday. Press HOLD to display Tuesday's 1st heating
period, and press PRGM to view each of the remaining
Tuesday's heating period time and temperatures. To view
ech day's heating program, press HOLD to change day and
them press PRGM to look at wach programming period for
the day. (You may change any time or temperature during
this procedure.)
3. Press RUN.
4. Move SYSTEM switch to COOL position.
5. Repeat step 2 to check cooling program.
6. Move SYSTEM switch to HEAT or COOL and press RUN to
begin program operation.
YOUR THERMOSTAT IS NOW COMPLETELY PROGRAMMED AND
READY TO PROVIDE MAXIMUM COMFORT AND EFFICIENCY!
CAUTION
!
TROUBLESHOOTING
Reset Operation
If a voltage spike or static discharge blanks out the display or
causes erratic thermostat operation you can reset the thermo-
stat by pressing
, and TIME at the same time. This also
resets the factory defaults to the configuration menu and
program. If the thermostat has power, has been reset and still
does not function correctly contact your heating/cooling ser-
vice person or place of purchase.
Batteries
For optimum performance, we recommend replacing batteries
once a year with fresh "AA" Energizer
®
alkaline batteries.
Symptom Possible Cause Corrective Action
N
o Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker. Replace fuse or reset breaker.
(common problems) 2. Furnace power switch to OFF. Turn switch to ON.
3. Furnace blower compartment door or Replace door panel in proper position to engage
panel loose or not properly installed. safety interlock or door switch.
No Heat 1. Pilot light not lit. Re-light pilot.
2. SYSTEM Switch not set to HEAT. Set SYSTEM Switch to HEAT and raise setpoint
above room temperature.
3. Loose connection to thermostat or system. Verify thermostat and system wires are securely Attached.
4. Furnace Lock-Out Condition. Heat may also Many furnaces have safety devices that shut the system
be intermittent. down when a lock-out condition occurs. If the heat works
intermittently contact the furnace manufacturer or local
service person for assistance.
5. Heating System requires service or Diagonistic: Set SYSTEM Switch to HEAT and raise the
thermostat requires replacement. setpoint above room temperature. Within a few seconds
the thermostat should make a soft click sound. This
sound usually indicates the thermostat is operating
properly. If the thermostat does not click, try the reset
operation listed above. If the thermostat does not click
after being reset, contact your heating and cooling
service person or place of purchase for a replacement.
If the thermostat clicks, contact the furnace manufacturer
or a service person to verify the heating system is
operating correctly.
No Cool 1. SYSTEM Switch not set to COOL. Set SYSTEM Switch to COOL and lower setpoint below
room temperature.
2. Loose connection to thermostat or system. Verify thermostat and system wires are securely attached.
3. Cooling System requires service or thermostat Same procedure as diagnostic for No Heat condition
requires replacement. except set the thermostat to COOL and lower the setpoint
below the room temperature. There may be up to a five
minute delay before the thermostat clicks in Cooling if
the compressor lock-out option is selected in the
configuration menu (Item 6).
Heat, Cool or Fan Runs Constantly 1. FAN Switch set to Fan ON. Check each wire connection to verify they are not
2. Possible short in wiring. shorted or touching together. No bare wire should
3. Possible short in thermostat. stick out from under terminal screws.
4. Possible short in Heat/Cool/Fan system. Try resetting the thermostat. If the condition persists
the manufacturer of your system or service person can
instruct you on how to test the Heat/Cool system for
correct operation. If the system operates correctly,
replace the thermostat.
Furnace Cycles Too Fast or Too Slow 1. The location of the thermostat and/or the size Item 2 in the Configuration Menu is the adjustment
(narrow or wide temperature swing) of the Heating System can influence the cycle rate. that controls the cycle rate. If an acceptable cycle
rate is not achieved using the FA (Fast) or SL
(Slow) adjustment contact a local service person for
additional suggestions.
Cooling Cycles Too Fast or Too Slow 1. The location of the thermostat and/or the size of the The cycle rate for cooling is fixed and can not be adjusted.
(narrow or wide temperature swing) Cooling System may be influencing thecycle rate. Contact a local service person for suggestions.
Thermostat Setting and Thermometer 1. Thermostat thermometer setting requires The thermometer can be adjusted +/- 4 degrees as listed
Disagree adjustment. in item 7 of the Configuration Menu. No other adjustment
is possible.
Clock Loses or Gains Time 1. Loss of power to thermostat and low batteries. The thermostat will maintain its program in memory even
with no power/no batteries but the clock time will be
incorrect when power is restored. See No Heat/No Cool/
No Fan (common problems) above for items to check in
the system.
Heat or Cool Starts Early 1. EMR activated See Configuration Menu (Item 4).
Thermostat Does Not Follow Program 1. AM or PM set incorrectly in program. Check current clock and program settings including
2. AM or PM set incorrectly on the clock. the AM or PM designations for each time period.
3. Voltage spike or static discharge. If a voltage spike or static discharge occurs use the
Reset Operation listed above.
Blank Display and/or Keypad Not 1. Loss of power and dead batteries. Replace batteries and check heat/cool system for
Responding 2. Voltage Spike or Static Discharge. proper operation. If a voltage spike or static discharge
occurs use the Reset Operation listed above.
TROUBLESHOOTING (cont.)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

White Rodgers 1F87-251 User manual

Category
Thermostats
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI