4874-842-C1-001, Rev. B (12/2020)
The following battery wiring diagrams are for AlphaCell
®
XTV 18V4 batteries.
NOTICE:
The AlphaCell
®
XTV 18V4 does not support the Smart AlphaGuard™ (SAG) battery charge
disconnected and the sense harness replaced with a standard DSM harness connected to the
Battery A/B, C/D connector on the DM3X. If the SAG is still installed, selecting the 18V battery
will result in a SAG Compatibility alarm.
NOTICE:
+ +
- -
A1
A2
A/B NEG
Black, Pin 1
Vbatt A1 [C] 18V
White, Pin 3
Vbatt A2 [C] 36V
Red, Pin 4
DM3X A/B, C/D
Connector
To Power Supply
Battery Voltage Sense Cable, 2 Battery string (Alpha p/n, 874-842-40)
Green, Pin 2
36V System
2 Battery String
858-061-19 (6')
1
2
3
4
5
6
7
8
Back of plug
To Transponder
In-line
Fuse
Battery Terminal Bolt Stack-up
(for 18V4 batteries)
Fuse Bolt Stack-up
(for 18V4 batteries)
Battery Sense
Cable or PTS
terminal
Optional Battery Cable
Battery Cable from
1/4-20 Nut
1/4-20 × 3/4" Bolt
1/4-20 × 1 1/4" Bolt
(M6 × 30mm Bolt for 18V4)
1/4-20 × 1/2” Bolt
(M6 × 12mm Bolt for 18V4)
Battery Sense
Cable or PTS
Battery Terminal
Battery
Terminal
Split Washer
Split Washer
Split Washer
Flat Washer
Flat Washer
Flat Washer
Battery Cable
from A1(-) to
B1(-)
Flat Washer
Spacer
Fuse