KI CafeWay ECRCB Care & Maintenance

Type
Care & Maintenance
PREVENTIVE MAINTENANCE GUIDE
• Check for loose or missing bolts and fasteners monthly.
• Check casters and latches for proper operation monthly.
• Oil all points labeled "1" with a light-weight oil twice per year.
• Parafnwaxthecenterslideandlatchassemblieslabeled"2" twice per year.
CARE & MAINTENANCE
CaféWay™ Tables
Model ECRCB
November 2014
1330BellevueStreet•P.O.Box8100•GreenBay,WI54308-8100•1-800-424-2432•www.ki.com
© 2014KruegerInternational,Inc.AllRightsReserved•CodeKI-62656/KI/PDF/1114
LATCH ADJUSTMENT
1. Withthetableintheuseposition,applyweighttotheunittoholditagainstthe
oor.Usingtheallenwrenchprovided,turntheallenbolt,ontheinsideofthe
centerleg,clockwisetotightenthelatchandcounter-clockwisetoloosenthe
latch.
2. Testlatchbyremovingweightfromthetable.Pushdownonthecenterofthe
table and release the latch located on the upper center leg between the table
tops.Holdthelatchinthereleasedpositionandslowlyliftthetable1to2
inches. Remove hand from the latch and with one hand on either table side lift
table into a tee position. Spring assists in the center legs will help you lift the
table to this position and will maintain the table in the tee position.
3. Pushthetablebackdowntotheuseposition,Verifythatthetablelatcheslock
the unit down by pulling up lightly on the center of the table. The table should
rise no more than
1
/
2
”.
4. Retestreleasetoverifysmoothrelease.
5. Applyparafnwaxorapprovedlubricanttothestrikeareaseveraltimesper
year.
  • Page 1 1
  • Page 2 2