Fujitsu UTW-KDWXG Installation guide

Type
Installation guide
Installation instructions
intended for the
professional technician
these must be kept safe
for subsequent consultation
7
8
3
Document n° 1749-2 ~ 03/07/2018
Fujitsu General (Euro) GmbH
Werftstrasse 20
40549 Düsseldorf - Germany
Subject to modications without notice.
Non contractual document.
FR EN DE EN IT
ES PT PL PT PT
DHW Kit
code UTW-KDW*G
To connect a DHW tank
to a monobloc heat pump
with an hydraulic unit WSYP100DG6
230 V
L
N
L N
2
4
" This manual mainly concerns the installation and
connection of the DHW kit.
" Please refer to the heat pump and DHW tank technical
manuals for how to install and congure these items.
- 2 -
DHW kit - code UTW-KDW*G
Contents
Description of the equipment . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Scope of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
The DHW sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Fitting the DHW kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Connecting to the heating circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Overall hydraulic layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DHW comfort temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
DHW tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installation instructions "1749 - EN"
- 3 -
DHW kit - code UTW-KDW*G
1 Description of the equipment
1.1 Package
1 package : DHW kit.
On reception, before you t anything, it is essential
that you check the parts received and search for any
damage caused during transport.
230 V
L
N
L N
2
4
gure 2 - Présentation du kit sanitaire
1.2 Scope of application
The plumbing kit enables you to connect a DHW
tank to a monobloc heat pump with an hydraulic unit
WSYP100DG6.
Warning !
The heat pump produces the domestic hot water (DHW),
which is then additively heated, if required, by electrical
back-up heating inside the tank: The hot water tank
should be equipped with an electrical backup in
order to ensure a target temperature above 45°C and
for legionella protection cycles.
1.3 The DHW sensor
The sensor must be installed in place of the thermostat
regulation bulb in the electrical back-up heating system.
- Temporarily remove the thermostat.
- Extract and isolate the regulation bulb from the
electrical back-up heating system.
- Place the hot water sensor in the housing for the
cylinder sensors.
- Re-install the thermostat.
DHW
sensor
ACI
system
Thermostat regulation
bulb for the electrical back-up
heating extracted from the glove
nger and isolated
1.4 Specications
Power absorbed . . . . . . . . . . . . W . . . . . . < 25
Maximum operating pressure . . . . bar . . . . . . . . 3
Supply voltage . . . . . . . . . . . . . . . .230V - 50HZ
Boiler connection diameter . . . . . mm . . . . 26x34
Flow/return diameter (male) . . . . . mm . . . . 26x34
Weight . . . . . . . . . . . . . . . . .kg . . . . . . . 2,4
Installation instructions "1749 - EN"
- 4 -
DHW kit - code UTW-KDW*G
98 70
97
450
803
845
457
84
479
gure 3 - Dimensions in mm (Hydraulic unit + DHW kit)
1.5 Description
Front view Side view
Installation instructions "1749 - EN"
- 5 -
DHW kit - code UTW-KDW*G
2
1
3
4
A
B
AB
2 Installation instructions
2.1 Fitting the DHW kit
" Carefully comply with the direction for tting
the distribution valve.
- Channel AB: Inlet from the hydraulic unit.
- Open channel A: Outlet to DHW tank.
- Open channel B: Outlet to the heating circuit.
• 1 - Remove the "pipe support" of the HP.
- Remove the heating ow sensor from the ow pipe
(see gure 7, page 6).
• 2 - Remove and suppress the HP ow pipe.
gure 1 - 3 - Fitting the DHW kit (not overtighten).
- Install the DHW kit into the HP. Tighten DHW kit ttings.
- Fix the ow sensor on the facility’s ow pipe (see gure
7, page 6).
• 4 - Fitting the "pipe support".
Good contact must be maintained between the heating
ow sensor and the pipework.
The contact surface between the piping and the sensor
should be free of rust and paint.
gure 4 - Fitting the DHW kit
gure 5 - Installing the DHW kit into the hydraulic unit
A, B, AB Distribution valve orientation.
C Hydraulic unit connection.
B
AB
A
C
Installation instructions "1749 - EN"
- 6 -
DHW kit - code UTW-KDW*G
2.2 Hydraulic connections
The connection must comply with good trade practice
according to local building regulations.
Tightening torque: 15 to 35 Nm.
The appliance must be connected to the installation
with union connectors and shut-off valves to facilitate
its removal.
Reminder: Seal everything when tting in accordance
with prevailing trade practice for plumbing work:
- Use suitable seals (bre seals, o-rings).
- Use Teon tape or hemp.
- Use sealing paste (synthetic depending on the case).
gure 6 - Hydraulic connections
Hydraulic Unit + DHW kit
gure 7 - Position of the ow temperature sensor
Flow temperature sensor on the HP… …with DHW kit
Installation instructions "1749 - EN"
- 7 -
DHW kit - code UTW-KDW*G
SE
PC
MH
R
AE
Rdyn*
OU
OU
SA
SA*
SA
AE
Ssa
M
B
A
AB
VD
KS
Caption :
AE - Electrical backup
KS - DHW kit
MH - Hydraulic unit
PC - Heating-cooling oor
R - Radiators
Rdyn* - Dynamic radiators
SA* - Room thermostat (option/without Rdyn)
SSa - DHW sensor
SE - Outdoor sensor
VD - Distribution valve
Heat Pump
Hydraulic Unit DHW Tank
Heating Circuit
OR
OR
2.2.1 Overall hydraulic layout
Conguration 1 : heating circuit and DHW tank (with electrical back-up)
Installation instructions "1749 - EN"
- 8 -
DHW kit - code UTW-KDW*G
2.3 Electrical connections
The electrical connections must only be made when all
the other tting operations have been completed (xing,
assembly, etc.).
" Do not place the sensor lines and the sector
supply lines near in order to avoid interferences
due to voltage points in the sector supply.
Ensure that all the electrical cables are housed
in the spaces provided for this purpose (inside
the lifting handles). To avoid undue interferences
due to voltage peaks, use a shielded cable
(standard telephone cable) to connect the sensors.
gure 8 - Cable bushing
Cable grommet
Sensors
Cable grommet
Power
• 7 - Place the relay-terminal block assembly in the
electrical box.
• 8 - Connect the hot water tank to the 3 and 4 terminals
of the X84 connector of the HP’s regulation board.
• 9 - Connect the bundle with the 5-stud connector to
X15.
• 10 - Connect the distribution valve.
• 11 - Connect the DHW tank’s resistance to Earth
terminal and to relay RP DHW on terminals 2 (L) and
4 (N).
• () - Connect the power supply of the tank’s integral
corrosion protection system (active anti-corrosion
protection), should it include one, to a continuous
power supply which is protected to the level required
by the manufacturer.
• 12 - Connect the hot water tank’s power supply
originating from the electrical case to the L, N, Earth
terminals of the DHW kit terminal block (Protection by
rated circuit breaker).
• Contract with the power provider
The heat pump's operation can be controlled to suit
special contracts (e.g. off-peak, day/night). In particular,
domestic hot water (DHW) at Nominal temperature will
be produced during the off-peak hours when electricity
is cheaper.
• 13 - Connect the “energy provider” contact to the EX2
inlet of the X11 connector.
230V on input EX2 = "Peak hours" information activated.
Set the 83 or 1620 parameter according to the desired
operation.
• () - Stick the label of wiring inside the front plate of the
hydraulic unit.
Installation instructions "1749 - EN"
- 9 -
DHW kit - code UTW-KDW*G
gure 9 - DHW kit Electrical connections
L
N
L N
L N
X15
X11
X84
230 V
L
N
L N
2
4
BK
BN
BU
M
DHW
sensor
Distribution
valve
“energy provider” contact
Electrical supply
230 V
Regulation
board
RPECS
Resistance of the
electrical back-up
(DHW tank)
8
7
10
9
13
12 11
Colour code
BK Black
BN Brown
BU Blue
Installation instructions "1749 - EN"
- 10 -
DHW kit - code UTW-KDW*G
2.4 DHW comfort temperature
To ensure a DHW setting over 45°C, the electrical
back-up heating or the boiler must be left on.
2.5 Details
2.5.1 DHW tank
The Summer/Winter switch (if present) must be set
to Summer to enable the electrical back-up heating
system to operate.
gure 10 - Distribution valve
A
B
Valve motor
release button
Manual operation:
opens all the channels for the lling
and/or drainage.
AB
Installation instructions "1749 - EN"
- 11 -
DHW kit - code UTW-KDW*G
3 Spare parts
When ordering spare parts, specify the appliance type
and serial number, the name of the part and the part
number.
Nr Code Designation ...............Type .......Qty
1 909136 Relay + Terminal block ............ . . . . . . .01
2 109444 Bundle ......................... . . . . . . .01
3 110866 Connector .................. 5 x ........01
4 198755 Sensor ........................ . . . . . . .01
5 134102 Isolating sheath ................. . . . 0,20 m
6 142735 Gasket .................26x34. . . . . . . .05
7 184064 Pipe ................................01
8 184065 Pipe ................................01
9 988109 Valve ...............................01
10 150322 Motor ...............................01
11 184066 Pipe ................................01
12 104863 Stop ...................... 1" F ........01
gure 11 - DHW kit Spare parts
230 V
L
N
L N
2
4
1
3
2
4
5
10
6
6
9
6
8
6
7
11
6
12
Installation instructions "1749 - EN"
Date of installation :
Contact of your heating technician or your after-sales service.
This appliance is marked with this symbol. This means that electrical and electronic products shall not be mixed with general household waste.
European Community countries(*), Norway, Iceland and Liechtenstein should have a dedicated collection system for these products.
Do not try to dismantle the system yourself as this could have harmful effects on your health and on the environment.
The dismantling and treatment of refrigerant, oil and other parts must be done by a qualied installer in accordance with relevant local and national regulations.
This appliance must be treated at a specialized treatment facility for re-use, recycling and other forms of recovery and shall not be disposed of in the municipal waste stream.
Please contact the installer or local authority for more information.
* subject to the national law of each member state
Subject to modications without notice. Non contractual document.
Complies with:
- Low voltage directive 2014/35/UE, under standards NF EN 60335-1 and NF EN 60335-2-102.
- Electromagnetic compatibility Diretive 2014/30/UE.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Fujitsu UTW-KDWXG Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI