RediPANEL Mounting System
Introduction
This document covers the installation procedure to use when
mounting the following modules in a panel:
Keypad Module (2705-K11Cx)
NEMA Module (2705-P2xCx)
8/16/32 Type 800A Module (2705-P11*, -P21*, -P31*)
This procedure replaces a mounting bracket arrangement with studs
and nuts.
Mechanical Installation
The following procedure replaces the mechanical installation which
appears in the following publications:
2705-ND002 - RediPANEL Keypad Modules
2705-800 - RediPANEL Push Button Modules
During module installation, refer to the accompanying mounting
template for exact dimensions.
To install the module:
1. Cut an opening in the panel approximately
149 x 219 mm (h x w) or 5.86 x 8.61 in (h x w)
2. Drill four or six (as required) 0.250 in (6.4 mm) diameter holes
for the top and bottom mounting studs in the positions indicated
on the template.
ATTENTION
!
Hazardous voltage. Contact with voltage may cause
death or serious injury. Always disconnect power to
sign prior to servicing.
IMPORTANT
If you are installing the module in an existing cutout,
skip to step 3.
Publication 2705-IN006A-EN-P - September 2003 2 PN 41061-327-01(1)
Supersedes Publication 2705-ND002-RN1 - February 1997 Copyright © 2003 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
3. Slide the module through the opening. The mounting tabs will
help seat the module tightly against a 0.062 in (1.6 mm) to 0.125
in (3.2 mm) thickness enclosure.
After sliding the module into the enclosure, the built-in
mounting tabs secure the module to the enclosure.
4. Install the mounting hardware and tighten to 8 in-lbs (0.908
N•m).