  • Hello! I am an AI chatbot trained to assist you with the Paradyne COMSPHERE 3800PLUS Release note. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
You have accessed an older version of a
Paradyne product document.
Paradyne is no longer a subsidiary of
AT&T. Any reference to AT&T Paradyne is
amended to read Paradyne Corporation.
1
3980-A2-GB60-00 November 1995
COMSPHERE 3800
Plus
Modems
Firmware Update for Release 2.05.12
Document No. 3980-A2-GB60-00
November 1995
This document contains information on changes in firmware Release 2.05.12 that are not documented in the
COMSPHERE 3800Plus Modems Users Guide (3980-A2-GB30-10). The information in this update sheet will be
incorporated into future releases of the Users Guide. In the meantime, keep this document with your Users
Guide.
New Configuration Option in Release 2.05.12
A new configuration option, BfrSizInBfrMode, follows the CellularEnhance configuration option in the
V42/MNP/Buffer group of the Configure branch. See pages 8-31 through 8-36 of the COMSPHERE 3800Plus
Modems Users Guide for information about the V42/MNP/Buffer group.
BfrSizInBfrMode: Normal
End Normal Minimized
Buffer Size In Buffer Mode. This configuration option limits the amount of outbound user data buffered while operating in
Buffer Mode. This can be used to avoid overloading DTEs attached to low-speed modems.
Normal – The modem performs standard buffering of user data.
Minimized – The modem makes minimal use of buffering.
The factory default is Normal.
The AT command equivalent is S-register S33=
n
, where
n
is 0 or 1:
S33=0 Normal (default)
S33=1 Minimized