Omnitron 2422-0-T Datasheet

Category
Network media converters
Type
Datasheet

This manual is also suitable for

iConverteriConverter
®
Modular system multiplexes up to sixteeen independent
T1/E1 circuits and 10/100/1000 Ethernet over ber or
Ethernet Virtual Connection (EVC)
Multiple groups of mux modules can be installed in the
same chassis
Remotely-managed conguration and testing enables
rapid deployment
Manageable via SNMP with Omnitron’s NetOutlook
®
Management Software or third party software
CLI management interface via TELNET or serial port
Optional connectivity to adjacent Ethernet switch modules
Commercial (0 to 50º C ) and wide (-40 to 60º C)
operating temperature ranges
iConverter Fiber Transport Modules
Fiber Transport modules are available for point-to-point
Ethernet or Carrier Ethernet Virtual Connection (EVC)
Small Form Pluggable (SFP) or xed ber transceivers, in
standard and CWDM wavelengths
Multimode, single-mode dual ber and single-mode
single-ber options.
iConverter 4xT1/E1 MUX Modules
In-band T1 loop-back
Out-of-band local loop-back on the copper and ber ports,
remote ber loop-back and circuit test modes
Supports balanced T1/E1 or unbalanced E1
Congurable alarm relay contacts for audio/visual fault
notication
24 hour T1/E1 statistic logging
Optional external I/O clock port
iConverter
Modular T1/E1 Multiplexer
T1/E1 and Ethernet Managed Multiplexer System
The iConverter Modular T1/E1 Multiplexer transports up to
sixteen T1/E1 circuits and 10/100/1000 Ethernet over point-
to-point ber, CWDM channel or Ethernet Virtual Connection
(EVC). This exible and scalable system is comprised of an
iConverter Fiber Transport module, and one or more iConverter
4xT1/E1 MUX modules installed in a 2, 5 or 19-module chassis.
Each iConverter Fiber Transport module and up to four
contiguous iConverter 4xT1/E1 MUX modules combine to form
a MUX group. A MUX group can connect with another MUX
group at the opposite end of a dedicated ber link or EVC.
A MUX group can also interoperate with a Managed iConverter
xed-conguration T1/E1 Multiplexer.
Multiple MUX groups can be installed in a chassis, enabling
high-density, star-topology deployments.
There are three Fiber Transport modules available: the
iConverter TM3, the iConverter GM3 NID plug-in module and
the iConverter GM4 NID plug-in module. The TM3 supports
Ethernet Link OAM with IEEE 802.3ah. The GM3 and GM4
NID modules support Carrier Ethernet Service OAM with IEEE
802.1ag Connectivity Fault Management and ITU-T Y.1731
Performance Monitoring. See the ber transport module
comparison table on page 2 for more information.
The Fiber Transport module is available with xed-ber or Small
Form Pluggable (SFP) transceivers, and feature two Ethernet
backplane ports for additional Ethernet connectivity to adjacent
modules. A common application of this feature is to combine a
4-Port switch module in the adjacent slot to provide a solution
with four additional 10/100/1000 ports.
The iConverter 4xT1/E1 MUX module supports four copper
RJ-48 ports for balanced T1/E1 applications. Adapter cables
are available to convert each RJ-48 interface to a BNC interface
for unbalanced E1 transport applications.
The 4xT1/E1 MUX module features an optional external clock
port that can be congured as a clock input or output. As an
input, the port can be connected to an external clock source,
such as a GPS receiver, to provide a common reference
clock for the module. As an output, the port can provide the
recovered T1/E1 clock from port 1 to other TDM equipment
at the site.
The T1/E1 Multiplexer modules are part of the iConverter multi-
service platform, and can be installed in a chassis equipped
with iConverter Network Interface Devices, media converters,
transponders and CWDM multiplexers. The multi-service
platform is capable of delivering Ethernet, TDM, SONET
and other services across a Wide Area Network. iConverter
modules can be added to this scalable architecture to expand
bandwidth capacity and add new services.
KEY FEATURES
The T1/E1 Multiplexer system features integrated management.
Monitoring, conguration and remote testing functions can be
accessed through the iConverter Fiber Transport module serial
console port, IP-based SNMP or IP-less OAM channels. Alarm
relays and SNMP traps provide fault notication for loss of
power, LOS and AIS.
SNMP management via NetOutlook provides a graphical user
interface for real-time port and module information, local and
remote conguration, and trap notication.
Page 2
iConverter Modular T1/E1 Multiplexer
SPECIFICATIONS
Model Type
iConverter TM3 Fiber Transport Modules
Protocols
10BASE-T, 100BASE-TX, 1000BASE-T,
100BASE-FX, 1000BASE-X Ethernet
Compliance UL, CE, FCC Class A, NEBS 3 Compliant
IP-Based Management TELNET, SNMPv1, SNMPv2c, SNMPv3
Frame Size Up to 10,240 byte frames
Copper Connectors Ethernet: RJ-45
Fiber Connectors
SFP Model:
Dual Fiber Model:
Single-Fiber Model:
Any MSA standard SFP
SC, ST
SC
Serial Connector
Mini DIN-6 female
Mini DIN-6 male to DB-9 female adapter
included
Dimensions W: 0.85” x D: 4.5” X H: 2.8”
Weight 8oz.
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4000m
Power
Typical input power requirements:
1.6A @ 3.3VDC
Connector: Power supplied by backplane
Temperature
Standard Operating:
Wide Operating:
Storage:
0 to 50º C
-40 to 60º C
-40 to 80º C
MTBF (hrs) 340,000 hrs
Model Type
iConverter 4xT1/E1 MUX Module
Protocols
ANSI: T1.403, T1.102
AT&T: T62411, ITU: G.703, G.704, G.706,
G.736, G.775, G.823, G.824, G.8261
ETSI: ETS 300 166
Compliance UL, CE, FCC Class A, NEBS 3 Compliant
Connectors T1/E1: RJ-48, Optional BNC, SMB (8484-4)
Clock I/O Port
(8486-4 only)
Input:
Output:
10 MHz, 1.544 MHz, or 2.048 MHz
Recovered clock from Port 1 SMB
Dimensions W: 0.85” x D: 4.5” X H: 2.8”
Weight 8oz.
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4000m
Power
Typical input power requirements:
1.6A @ 3.3VDC
Connector: Power supplied by backplane
Temperature
Standard Operating:
Wide Operating:
Storage:
0 to 50º C
-40 to 60º C
-40 to 80º C
MTBF (hrs)
410,000 hrs
MANAGEMENT
iConverter Fiber Transport Modules
Feature TM3 GM3 GM4
TELNET, SNMP v1, v2c, v3
4 4 4
SSH Secure Management
4
Zero-Touch Provisioning
4 4
ITU-T Y.1564 Service Testing
4
RFC 2544 Throughput Testing
4
IEEE 802.3ah
4 4 4
IEEE 802.1ag
4 4
ITU-T Y.1731
4 4
Tag VLAN (Q-in-Q)
4 4
Service Multiplexing (EVPL)
4 4
Rapid Spanning Tree Protocol
4 4
G.8031 Linear Protection
4
G.8032 Ring Protection
4
Y.1588 Clocking
4
Rate Limiting
4 4
MIB Statistics (RMON)
4 4 4
Fault Propagation Link Modes
4 4 4
L2CP Policy Manager
4 4
L2PT
4 4
FIBER TRANSPORT MODULES
For GM3 or GM4 specications, see the respective data sheets.
Page 3
iConverter Modular T1/E1 Multiplexer
APPLICATIONS
The iConverter Modular T1/E1 Multiplexer system is designed
for service provider, enterprise, government and energy/utility
networks.
Enterprise and government applications include extension of
multiple T1/E1 circuits from a service provider demarcation
point, and building-to-building PBX connectivity.
Service provider and utility applications include mobile
backhaul and business services that require delivery of multiple
T1/E1s and/or Ethernet.
Mobile Backhaul
In this application diagram, iConverter Modular T1/E1
Multiplexers deliver Ethernet and T1 mobile backhaul.
At the Mobile Switching Center, two iConverter MUX groups
are installed in a high-density 19-module chassis, and connect
to TDM and IP networks. The iConverter MUX groups convert
RJ-45 Ethernet and T1 interfaces to ber, and transport the
multiplexed data over the ber links.
At the Cell Sites, MUX groups are installed in 2-module or
5-module chassis. The ber link with multiplexed data is
converted back to RJ-45 Ethernet and T1 interfaces where
they connect to the tower’s radio equipment.
Using the GM3 or GM4 Transport modules enables a seamless
migration from 2G (T1s), to 3G (T1s and Ethernet), to 4G/LTE
(Carrier Ethernet).
Ethernet and TDM Business Services
In this application diagram, iConverter Modular T1/E1
Multiplexers deliver Ethernet and T1s over an Ethernet Virtual
Connection (EVC). A two module chassis with a GM4 Fiber
Transport Module and a T1/E1 MUX module are installed at
each customer location.
The EVC transports the business Ethernet and four T1 circuits
between the two customer locations across a Carrier Ethernet
network. The Ethernet transports business data, and the T1s
are used for telephony services (PBX to PBX connectivity).
ORDERING INFORMATION
Page 4
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • [email protected] • 140 Technology Dr., Irvine, CA 92618
iConverter Modular T1/E1 Multiplexer
© 2013 Omnitron Systems Technology, Inc. All rights reserved. iConverter and NetOutlook are Registered Trademarks of Omnitron Systems Technology, Inc.
Trademarks are owned by their respective companies. Specications are subject to change without notice.
091-12420-001D 1/13
iConverter TM3 Transport Module
Port Conguration Fiber Type Distance Wavelength P1 Connector Type
Tx
Lambda
(nm)
Rx
Lambda
(nm)
Min. Tx
Power
(dBm)
Max. Tx
Power
(dBm)
Min. Rx
Sensitivity
(dBm)
Max. Rx
Power
(dBm)
Min Att.
Link
Budget
(dB)
P1 P2 (nm) ST SC SFP
FF UTP MM-DF 220/550m 850 2420-0-T 2422-0-T - 850 850 -10 -4 -17 -3 - 7
FF UTP SM-DF 12km 1310 2421-1-T 2423-1-T - 1310 1310 -9.5 -3 -19.5 -3 - 10
FF UTP SM-DF 34km 1310 2421-2-T 2423-2-T - 1310 1310 -5 0 -23 -3 3 18
FF UTP SM-DF 80km 1550 - 2423-3-T - 1550 1550 -5 0 -23 -3 3 18
FF UTP SM-DF 110km 1550 - 2423-4-T - 1550 1550 0 5 -24 -3 8 24
FF UTP SM-DF 140km 1550 - 2423-5-T - 1550 1550 2 5 -28 -8 13 30
FF UTP SM-SF 20km 1310/1550 - 2430-1-T* - 1310 1550 -9.5 -3 -20 -3 - 10.5
FF UTP SM-SF 20km 1550/1310 - 2431-1-T* - 1550 1310 -9.5 -3 -20 -3 - 10.5
FF UTP SM-SF 40km 1310/1550 - 2430-2-T* - 1310 1550 -3 0 -20 -3 3 17
FF UTP SM-SF 40km 1550/1310 - 2431-2-T* - 1550 1310 -3 0 -20 -3 3 17
SFP UTP - - - - - 2439-0-T** Order the appropriate SFPs separately. Visit the Optical Transceivers web page.
SFP SFP - - - - - 2499-0-T** Order the appropriate SFPs separately. Visit the Optical Transceivers web page.
FF - Fixed Fiber, UTP - Unshielded Twisted Pair, SFP - Small Form Pluggable Transceiver
*When using single-ber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.
**Order ber or copper SFPs separately
To order a wide temperature (-40 to 60°C) TM3 module, add a “W” to the end of the model number.
See the GM4 or GM3 NID data sheets for ordering information.
Visit the GM4 NID web page
Visit the GM3 NID web page
iConverter 4xT1/E1 MUX Module
4 T1/E1 4 T1/E1 with Clock I/O
Model Number 8485-4 8486-4
To order a wide temperature (-40 to 60°C) 4xT1/E1 MUX module, add a “W” to the end of the model number.
Accessories
9140-3 RJ-48 to dual BNC plug cable, 3m
9142-1 RJ-48 Alarm Breakout Cable
9144-6 50 OHM mini-coax plug to BNC plug adapter cable, 6”
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Omnitron 2422-0-T Datasheet

Category
Network media converters
Type
Datasheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI