5
GENERAL INFORMATION
Before installing and/or using this hood, please read the instructions carefully and
thoroughly.
Before you install the hood, make sure the voltage (V) and frequency (Hz) indicated on the
serial and technical data plate located inside the appliance correspond with the voltage
and frequency available in the place of installation.
☞ After having removed the packaging, check that the appliance is intact. If in doubt, do not use the
appliance and contact professionally qualified personnel.
☞ All installation and adjustment operations should be carried out by a qualified technician in
accordance with the regulations in force. Specific indications are given in the section intended
for the installer.
☞ Clean the hood according to the manufacturer's instructions, especially for the deposits formed
on the dirty surfaces to avoid any risks of fire.
☞ Ensure the burners are always covered so as not to cause the hood filter to overheat.
☞ When frying food, never leave the pan unattended: the oil inside the pan could overheat and
catch fire. If the pan contains oil which has already been used to fry, the risk of spontaneous
ignition is even greater.
☞ It is strictly forbidden to flambé food beneath the cooker hood.
☞ The air collected should not be conveyed in a duct used for the discharge of exhaust fumes from
appliances that run on energy sources other than electricity.
☞ Suitable ventilation of the room must be provided when the hood and appliances that run on
energy sources other than electricity are used at the same time.
☞ If the hood is used in the outdoor venting mode, check the condition of the exhaust duct should
the latter have been left unused for an extended period of time.
☞ Remember to pay attention to the local norms in force and to the regulations from the competent
authorities on the subject of air exhaust when the hood is operating in the outdoor venting mode.
☞ All advice given on this matter must be followed scrupulously in order to avoid possible fires.
☞ FAILURE TO OBSERVE THE ABOVE-MENTIONED INDICATIONS AS TO THE INSTALLATION,
MAINTENANCE AND SUITTABLE USE OF THE HOOD RELIEVES THE MANUFACTURER
OF ALL LIABILITY.
INSTALLATION
The accessories required for the installation of the hood can be found inside the latter.
The hood is convertible and can therefore be installed in either the OUTDOOR VENTING or
the AIR RECIRCULATION mode. If the hood is used in the OUTDOOR VENTING mode,
connect opening N (125/150 mm diameter) (fig. 1) to an exhaust duct connected directly to
the outside and which is 150 cm
2
minimum in cross-section. The lowest part of the hood
should be at least 70 cm from the hob.
IN NO CASE WHATSOEVER SHOULD THE HOOD BE CONNECTED TO EXHAUST
DUCTS FROM OTHER APPLIANCES THAT RUN ON ENERGY SOURCES OTHER THAN
ELECTRICITY (water heaters - boilers - stoves - etc.). The appliance must not be placed
above stoves with a top radiant plate.
ASSEMBLY INSTRUCTIONS
There are three main types of supports for anchoring a hood to a wall. As a rule, each hood
has two main anchoring points: both at the back, one on the right-hand side and one on the
left.
1ST TYPE OF SUPPORT
This support is assembled onto the hood and allows for the adjustment of the same both
vertically (screw L) and horizontally (screw F). For the installation, L-shaped hooks must be
fastened to the wall (see detail E in figure 2).
2ND TYPE OF SUPPORT
This type of support, too, is already assembled on the appliance and allows for the adjustment
of the same vertically only, by turning the screw situated on the high part of the hood (See
“2
nd
TYPE OF SUPPORT Side b”). As for the 1
st
type of support, L-shaped hooks must be
fastened to the wall for installation.
TABLE OF CONTENTS
GENERAL INFORMATION .................................. 5
INSTALLATION ............................................... 5
ASSEMBLY INSTRUCTIONS ......................... 5
ASSEMBLY OPERATIONS ........................... 6
MOTOR CONNECTION ............................... 6
CHIMNEY DUCT ASSEMBLY ........................ 6
OPERATING MODES ................................. 7
AIR RECIRCULATION ................................ 7
ELECTRICAL CONNECTION ......................... 7
OPERATION ................................................. 7
PUSH-BUTTON CONTROLS .......................... 7
SLIDER CONTROLS ................................... 7
TOUCH CONTROLS ................................... 7
DESCRIPTION OF REMOTE CONTROL FEATURES.7
M
AINTENANCE .............................................. 8
A) CLEANING ......................................... 8
B) CLEANING THE METAL GREASE FILTER .... 8
C) LAMP REPLACEMENT ........................... 8
D) STARTER REPLACEMENT ...................... 8
E) CARBON FILTER REPLACEMENT ............. 8
THE GUARANTEE .......................................... 8
fig.1
1st TYPE OF SUPPORT
fig.2
D
E
C
E
1
2
1
2
D
D
L
G
F
B
N
R