American Standard 2590.101.002, 2590.101.295 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the American Standard 2590.101.002 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
COLLAR ON
MOUNTING NUT
8
Certified to comply with ANSI A112.18.1
Installation
Instructions
Monoblock Lavatory Faucet with
Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
1
2
4
3
1
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
GROOVE
(FAUCET
BASE)
MOUNTING SURFACE
6
4
7
5
Seat SEAL (1) into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through the mounting hole of lavatory or
mounting surface. Fig. A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Fig. B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
2590.101
STUDIO
Fig. B.
Fig. A.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the rst time, every time.
M968626 REV.1.4
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
1
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body.
Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3).
Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY.
Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
1
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
2
2
3
3
1
1
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
INSTALL DRAIN FROM
BELOW FIXTURE
5
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DRAIN
BODY
4
2
DRAIN
OUTLET
1
3
4
REAR
OF SINK
M968626 REV.1.4
CHECK OPERATION OF POP-UP
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
3
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
2
M968626 REV.1.4
1
12
4
M968626 REV.1.4
8
3
1
2
2.5mm HEX KEY
2
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
4
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
10
“P” TRAP
WASTE
OUTLET
3
1
OFF
ON
COLD
HOT
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
4
A
B
D
5
6
REMOVE
INSTALL
7
10
11
SERVICE
To remove or replace cartidge:
To adjust HOT LIMIT SAFETY STOP:
Turn valve to OFF position.
Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).
Pull off HANDLE (3) and CAP (4).
Unthread CARTRIDGE NUT (5) and remove.
Pull out CARTEIDGE (6).
Inspect CARTRIDGE (6) and O-RINGS (7) for debris and
clean if necessary.
Clean MANIFOLD (8) and rinse clean.
Reinstall CARTRIDGE (6) and O-RINGS (7) onto MANIFLOD (8).
Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from OFF to ON and
HOT to COLD position. Do not force - handle turns only 90˚.
Turn off hot and cold water
supplies before beginning.
CAUTION
By restricting HANDLE rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (9) reduces risk of accidental scalding. To lower the
maximum hot water temperature of your faucet, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP (9).
Note: The HOT LIMIT SAFETY STOP (9) is set at the maximum
hot temperature setting from the factory. Fig. A.
ADJUST HOT LIMIT SAFEYT STOP
Remove HANDLE ASSEMBLY (3), CAP (4) and CARTRIDGE NUT (5).
Set the CARTRIDGE STEM (10) to the OFF position and rotate it
clockwise until stops. Fig. B.
Rotate the CARTRIDGE STEM (10) counter-clockwise to a colder
setting mark in the HOT LIMIT SAFETY STOP (9). Fig. C.
Lift up the HOT LIMIT SAFETY STOP (9) and rotate it to coincide
again with the stop in the base of the CARTRIDGE STEM (10). Fig. D.
Replace the HOT LIMIT SAFETY STOP (9).
Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).
GEAR
GEAR
GEAR
10
9
9
C
10
9
+HOTTER
SETTING
MARKS
COLDER
GEAR
10
9
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.
REMOVE
CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE
CAM CAP
5
Fig. A.
Fig. C.
STOPPER
DOWN
1
M968626 REV.1.4
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable
.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
6
M968626 REV.1.4
/