Vulcan-Hart VHL3D Specification

Type
Specification

This manual is also suitable for

Item # _____________________________
C.S.I. Section 11420
A2780
ISO9001
Vulcan-Hart Co.
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
F-32575 (10-03)
SPECIFICATIONS:
Direct steam, Super Steamer, Vulcan-Hart Model No. (VHL2D)
(VHL3D). 6 psi pressure steam cooker. Cooker body is 8
gauge satin nish type 304 stainless steel exterior. Doors have
a removable aluminum alloy inner liner with full perimeter
gasket and sealed by turning a "T" type handle. The door
cannot be opened while the steamer is on. Automatic timed
compartment controls with 60 minute timer (add sufx "S" to
model number). Lift out stainless steel wire Adapt-A-Pan
TM
supports eight 2
1
/2", six 4", or four 6" deep food pans (one for
2 compartments)(two for 3 compartments) and one manual
pull out shelf. Cooker mounted on a 2" diameter welded
stainless steel tubing leg stand with 6" adjustable anged feet,
for oor anchoring. Direct steam supply at 10 to 50 PSI with a
ow of (2 compts., 80 lbs. steam/hr.) (3 compts., 115 lbs.
steam/hr.).
Exterior dimensions:
VHL2D: 36"w x 33"d x 58"h (61"h with cabinet base).
VHL3D: 36"w x 33"d x 66"h (76"h with cabinet base).
U L listed. Classied by U L to NSF Std. #4.
VHLD SERIES
SUPER STEAMER, DIRECT STEAM
TWO OR THREE COMPARTMENT MODELS
MODELS: VHLD SERIES Direct Steam Super Steamer
VHL2D (S) (P) 2 compartments
VHL3D (S) (P) 3 compartments
STANDARD FEATURES
Direct steam supply at 10 to 50 PSI with a ow of (2 compt.
- 80 lbs. steam/hr.) (3 compt. - 115 lbs. steam/hr.)
6 psi pressure steam cooker.
Cooker body is 8 gauge satin nish type 304 stainless steel
exterior. Doors have a removable aluminum alloy inner
liner with full perimeter gasket and sealed by turning a
"T" type handle. The door cannot be opened when steamer
is on.
Automatic timed compartment controls with 60 minute
timer. (Add sufx "S" to model number.)
Lift out stainless steel wire Adapt-A-Pan™ supports eight
2
1
/2", six 4" or four 6" deep food pans (one for 2
compartments)(two for 3 compartments) and one manual
pull out shelf.
Cooker mounted on a 2" diameter welded stainless steel
tubing leg stand with 6" adjustable anged feet for oor
anchoring.
One year limited parts and labor warranty.
OPTIONS
28" high cabinet with stainless steel front full height doors,
slip-off stainless steel side and aluminized rear panel with
6" adjustable legs with anged feet for anchoring.
Pre-Vent
TM
, automatic load compensated timed, combination
pressure and free venting cooking with automatic exhaust.
(Add sufx "P" to model number).
Correction package:
a. Cabinet door with hasp (lock by others).
b. Security type tamper resistant fasteners.
c. Control cover (lock by others).
Control circuit step down transformer to 120V, if higher than
120 volt.
Second year extended limited parts and labor warranty.
ACCESSORIES
Stainless steel back panel.
Manual sliding shelf (Qty. ____).
Removable 12 x x20 sliding shelf (Qty. ____).
Adapt-A-Pan™ support (Qty. ____).
(Shown on optional cabinet base)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specications without notice.
F-32575 (10-03)
VHLD SERIES
SUPER STEAMER, DIRECT STEAM
TWO OR THREE COMPARTMENT MODELS
SERVICE CONNECTIONS:
Steam Supply:
3
/4" NPT for 10 - 50 psi direct steam.
Electric Connection for Controls: 120/60/1, 300 watt maximum
power supply with grounding wire required. (For other than 120 volt
supply, consult factory for location of this conneciton.)
Drain: Condenser box, compartment and boiler, 2" NPT. (Provide
an open air gap type drain within 12" of condenser box and for best
results at a distance so that steam vapors will not enter the steamer
from underneath the control area. Do not connect solidly to any
drain connection.)
EQUIPMENT CLEARANCE:
Rear: 6" Right and left side: 6"
NOTE:
• Dimensionswhichlocatetheaboveconnectionshaveatoleranceof
+ or -3" (+ or -75 mm).
• Installationofbackowpreventers,vacuumbreakersandotherspecic
code requirements is the responsibility of the owner and installer. It is
the responsibility of the owner and installer to comply with local codes.
• Plasticdrainsarenotrecommendedduetoinherentlimitedtempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge water
temperature to be that of the condensate temperature of 140°F or less.
• Thisapplianceismanufacturedforcommercialinstallationonlyandis
not intended for home use.
PAN CAPACITIES (Per compartment)
MODEL 2
1
/2" deep 4" deep 6" deep 18" x 26"
VHLD 8 6 4 6
  • Page 1 1