1. Locateairinletcoverplateonreplace‘soutersurround.Removescrewsandplate.
2. Cutoutanyvisibleinsulationthatmayobstructairow.
3. Extendexducttoattachairinlettube.
4. Insertinnertabofinlettubeintoslotnexttoopening.Placeoutertabofinlettubeoverholenexttoopening.
5. Securewithscrewsremovedfromcoverplateinstep1.
6. Constructa8"x8"insideframingoropeningonexteriorwall.
7. Installoutsideairventterminationinalocationthatwouldnoteventuallybeobstructedbybushes,snoworotherobstruc-
tions.Locateventnearreplacetomakeexductinstallationeasier.
8. Theexductsuppliedmeasuresapproximately10"compressedandupto3feetextended.
OutsideAirVent
Termination
112098-01
Rev.E
09/08
NOTAUPC
AK-6WE
OutsidE Air Kit
fOr WOOd burning firEplAcE
INSTALLATION INSTRUCTIONS
Insulation
LeftSide
Mounting
Shown
SecuretoCollarwith
MetalTape,Screws
orTieStraps
(NotSupplied)
InsertInnerTabof
InletTubeIntoSlot
onOuterSurround
AirVentLocation
MustAllowFor
Bushes,Snowand
OtherPossible
Obstructions
RemoveKnockout
SheetMetalScrew
TabinNotch
AirInletTube
The maximum height for the air vent can not exceed
3 feet below the ue gas outlet of the termination.