Amperes iPX5400 is a transceiver unit that works in duplex (paging) mode, connects in pairs, and communicates without full IP solutions. It's a simple device allowing peer-to-peer communication. It can reduce the risk of lightning surges by sending audio from a Guard House's paging mic to the main system through a fiber link, and avoid the need to lay new cables by transmitting audio or data rack-to-rack. It can also connect with a wireless AP in areas where new cables are impossible to lay.

Amperes iPX5400 is a transceiver unit that works in duplex (paging) mode, connects in pairs, and communicates without full IP solutions. It's a simple device allowing peer-to-peer communication. It can reduce the risk of lightning surges by sending audio from a Guard House's paging mic to the main system through a fiber link, and avoid the need to lay new cables by transmitting audio or data rack-to-rack. It can also connect with a wireless AP in areas where new cables are impossible to lay.

INSTRUCTION MANUAL
iPX5400
Ethernet Transceiver
Thank you for choosing another quality product from Amperes Electronics.
Introducing another product for the convenience of installation when it is required to send audio / data from a distance
away. iPX5400 is a transceiver unit, which is able to operate in duplex mode ( paging ), works in pair in LAN environment
or connected directly via UTP cable or Fiber through a converter. It is a simple device allowing peer to peer communication
without the need to employ full IP solutions in your system.
Among applications includes :
- Sending audio from Guard House's paging mic to main system at a distance away through fiber link thus reducing the
risks of lightning surge
- Rack to rack audio / data transmission through existing LAN, thus avoiding the need to lay new cables
- Apply it with wireless AP for areas where laying of new cables are not feasible.
R
Parts Identification
2
PAGE 2 iPX5400 | ETHERNET TRANSCEIVER
3
6
7
1
1. INDICATOR LEDS
LEDs for Power, Server, Status and Streaming.
2. POWER PORT
24V DC power supply input.
3. ETHERNET PORT
Ethernet Port for connection to network switch.
4. RESET BUTTON
Button for resetting the unit to factory default. Use only when required as setting done previously would be lost.
5. RELAY CONTACT
This ports provide a dry contact which can be used to connect E/M overriding signal or activate ALL CALL at
speaker zone selector.
6. EXTERNAL MESSAGE TRIGGER PORT
Ethernet message player can be linked to it and can be broadcasted to the speakers when this port is triggered.
A voltage free contact is recommended to trigger the message playback.
7. RS485 PORT
For data Transmission (RS485) from PD paging mic or output data for TD6240 / 6080 controls.
8. SIGNAL INDICATOR
LED to indicate audio signal’s presence.
9. MIC AUDIO INPUT
Audio input signal from paging mic with balanced line level.
10. AUDIO OUTPUT PORT
Audio output from client for connection to mixer, etc with balanced line level.
Front View Rear View
9 10
5
4
8
R
iPX5400 | ETHERNET TRANSCEIVER PAGE 3
Connecting to iPX5400
2. Connecting PM1000 mic to iPX5400 with dry contact activation
Normal mic such as PM1000 can use to transmit with a dry contact as activation key. At the receiving end, there shall be audio
output for link to mixer, etc and another dry contact for other general purpose. An example is to use a handheld mic as emer-
gency mic at guard house to trigger an ALL CALL at system rack for emergency announcement.
Application Example : Peer to Peer Direct Connectivity
PD Series Mic
Main PA Rack
Cat5e / Cat 6 ( non crossed ) or
Fiber optic cable via LAN - FO converter
or through existing
LAN
Music Player
24V DC Power
Speakers
iPX5400
24V OR Contact if applicable
D
AMPLIFIER MONITOR
AMPLIFIER OUTPUT LE VE L MET E R ( dB )
AMPLIFIER OUTPUT SI GNA L
8 9
7
11 12
4
3
2
1
OFF
MAX
MONITOR VOLUME
7
5
6
3
4
8
AMPLIFIER SELECT
1
11
12
9
10
2
10
654321
-10 -5 0 3 6
AM 4120
amperes
TEST
MIC
EMERGENCY PA GING P ANE L
SIREN ACTIVATE
POWER
FIR E
amperes
AM 6000
PT 1800
amperes
WEEKLY PROGR AM TIME R
CH5 CH6CH3CH4 CH7 CH8 STA TU SWEST
RELAY OUTPUT CONT AC T MELODY
CH1 CH2
ENTER DOWNUP
ACTIVEDATA
POWER
PRIORITY 1
PRIORITY 2
24 CH DATA DECODER / R E C EI VE R
amperes
TD 6240
VR 7000
3
2
1
6
5
4
3
2
1
6
5
4
5
2
4
3
6
1
4
3
2
1 1
2
3
5
6
4
5
6
amperes
ZS 5602
amperes
BGM / PAGING ZONE S E LE C TOR
21 3 54 6 1 2 3 4 65
ALL CALL
BACKGROUND MUSIC PAGING ZONE SELEC TIO N
amperes
BP2000
BLANK PANEL
POWER
OFF S EL E CT
TUNER
CD
CASS
OFF
MASTER
MUSIC SOURCE
SIG IN
BASS
MAXMIN
EXT INPUT
MAX MAXMIN
SOURCE
MIN
SIG IN
CHIME MIXER TREBLE
MAXMIN
TONE CTRL
CH5 CH6CH4
SIG INSIG IN SIG IN
MAXMIN MAXMIN MIN
CH3CH1 CH2
SIG INSIG IN
MAXMIN MAXMIN MAXMIN MAX
AUX
SIG IN
PRE AMPLIFIER MIX ER
amperes
MX
2222
O
I
CH1 CH2 CH4CH3 C H5 CH6
STATUS
MENU ENT ER NEXTPRE
BUZZER
NORMAL
FAULT
SPEAKER LINE S UR VE ILL ANC E
LS 4600
amperes
BATTERY
9400
PS
REGULATED DC P OW ER S UP P LY
DC OUT
MAINS
POWER
amperes
O
I
STANDBY AMPLIFIER CHA NGE O VE R
STANDBY TAKEOVER
NORMAL
AC 3601
amperes
21 3 54 6
AUTO STANDBY AMP C HAN GE OV E R
FAULT
STANDBY
5 64321
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT
AMP.FAULT / LINE GND
AMP. NUMBER
AMP.OPERATIONAL
AX 700
amperes
amperes
MxP 2188
MONITOR SPEAKE R
LOCAL PAGE ZONE
t11.25;SPEAKER VOLUME
8
7
6
5
4
3
2
1
MONITORALL
EMER
DOWN
UP
PRE NEXT
PAGE
ZONE 5
ZONE 6
ZONE 7
ZONE 8ZONE 4
ZONE 3
ZONE 2
ZONE 1
Matrimix Paging
8x8 MATRIX MIXER
VP 1000
amperes
VENT PANEL
MENU
amperes
O
I
POWER
UP
DOWN
Q
uantum
2000 SERIES
QP 2500
500W POWER AMPLIF IE R
ACTIVEDATA
POWER
PRIORITY 1
PRIORITY 2
8 CH DATA DECODER / Z ONE S E LE CT OR
amperes
TD 6080
OVERRIDE
21 3 54 6 7 8
ALL CALL
O
I
VOLUME
HEADPHONE
MONITOR SPEAKE R
MP3 / CD PLAYER / T UNE R
POWER
CD 1001
amperes
APS SCAN
MEMORY BAN
RESET
-
+
MUTE SOURCE
SHUF RPT
AX 3700
AMPLIFIER AUTO F AULT C HANG E OV ER
AMP. FAULT
AMP. CHANGEOVER
AMP. NORMAL
5 64321
6
PILOT TONE
STANDBY AMP. FAULT
AMP. NUMBER
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT
PILOT TONE
STANDBY AMP. FAULT
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT
amperes
MENU
amperes
O
I
POWER
UP
DOWN
Q
uantum
2000 SERIES
QP 2500
500W POWER AMPLIF IE R
MENU
amperes
O
I
POWER
UP
DOWN
Q
uantum
2000 SERIES
QP 2500
500W POWER AMPLIF IE R
R
or
audio &
data
audio only
24V DC Power
R
Audio to
Mixer
RS485 for Zone
Controls
Remote Location such as Guard
House, Reception etc
iPX5400
1. Connecting PD series paging mic to iPX5400
This is usually applied when is required to install a paging microphone a distance away from the rack such as guard house,
remote office or at different building.
Audio ( line level output ) and RS485 output shall be connected to iPX5400 as per diagram below, and at the receiving end,
audio shall be fed to mixer and the RS485 data shall go to TD decoder for zone activation. In this mode, duplex operation is
allowed.
3. Transmitting Music via iPX5400
iPX5400 allows high quality music audio to be transmitted via existing LAN or fiber optic. They works in pair at simplex mode.
Analogue input to iPX5400 shall be assigned as transmitter and the other end as receiver.
For each type of application above, user shall need to set the connection mode at web browser.
Refer to page 5: System configuration; Connection mode.
IMPORTANT NOTE:
iPX5400
Amp / Mixer
Decoder
data
audio
Cat5e / Cat 6 ( non crossed ) or
Fiber optic cable via LAN - FO
converter or through existing
LAN
PD Series Mic
iPX5400
data AB
EX2800
audio
7 9
7
10
PM1000 Mic
iPX5400
PM 1000
amperes
PAGING MICROPHONE
CHIME & TALK
PUSH TO TALK
audio
remote trigger
iPX5400
Amp / Mixer
24V or contact if applicable
Cat5e / Cat 6 ( non crossed ) or
Fiber optic cable via LAN - FO
converter or through existing
LAN
6
9
6
10
Music Player
iPX5400
audio
iPX5400
Amp / Mixer
audio output
Cat5e / Cat 6 ( non crossed ) or
Fiber optic cable via LAN - FO
converter or through existing
LAN
10
9
Device Setup Via Browser
PAGE 4 iPX5400 | ETHERNET TRANSCEIVER
iPX5400 shall require some simple setups, kindly follow the step by step instructions as listed below. The unit shall be con-
nected to LAN network to form a complete system. The default IP address is 192.168.0.100. Login page shall appear and
the default User ID and Password are both “admin”.
Info / Main Page
Info: Providing hardware, network and Application
information. This shall be the first page once you
entered the system’s http browser.
Network Configuration: For configuration of
IP address and its related ports.
System configuration: For Application
Settings.
Network Configuration
Unless required, you are recommended to change
the IP address only, leaving other setting such as
port number as default. Once the address has
been changed to suit the environment, click the
“Save Changes” button.
Hardware Information
Firmware Version
Hardware Revision
Serial Number
Device Name
Network Information
IP4 Address
Subnet Mask
Gateway Address
Application Information
Linked To
Data Port
MAC Address
Network Settings
IP4 Address
Subnet Mask
Gateway Address
Application Settings
Data Port
iPX5400 | ETHERNET TRANSCEIVER PAGE 5
Device Setup Via Browser
System Configuration
Application Setting: The volume, bass and treble for
selected groups can be set accordingly. The default source
refers to the unit’s selected source every time it is turned on.
Device Name: You can rename the device name.
Connection Mode: Set mode of connection.
Remote IP: The IP address of a network to which information
is being transmitted.
Volume: Volume setting.
Bass, Treble: Setting the level to suit the environment.
Web Page Theme: You can choose the theme of the web
page.
Authentication: You can alter the user name and pass-
word to avoid unnecessary access to the system.
Firmware Update: Both the browser and firmware are
stored in the unit’s memory. Should there be any updates
available, use this section to perform system upgrades
accordingly.
Application Settings
Device Name
Connection Mode
Remote IP
Volume
Bass
Treble
Web Page Theme
Authentication
New User Name
Old Password
New Password
Confirm Password
Firmware Update
File No file chosen
System Bootloading (Firmware / Browser Update)
System firmware shall be updated once in a while when new features are available or to fix bugs. There are 2 methods of
doing;
To update the firmware via html page, enter the IP Address (192.168.0.100) and go to ‘System Configuration’ page under
“ firmware updates ” for firmware update.
Update via Browser
To update the firmware, choose file ( new file downloaded from website or
source directly from us ) and click update.
Firmware Updates
File
After finish updating firmware, the browser automatically restart.
IPX5400.acfr
PAGE 6 iPX5400 | ETHERNET TRANSCEIVER
System Bootloading (Firmware / Browser Update)
1. Default reset: Press & hold the reset button until LED “streaming” ON.
2. At the web browser, enter the IP address 192.168.0.100 and the page below shall appear. This is a “Safe Mode” page
for Browser or Firmware update.
Server Reset Bootloading
If the client “hanged”, it is required to perform system reset by :
Click the Upload Firmware button to find the updated
firmware file.
Find the updated firmware file.
Ready to upload, click Upload
button to upload the firmware.
Updating progress
After finish updating firmware, the browser automatically restart.
IPX5400.acfr
IPX5400.acfr
IPX5400.acfr
IPX5400.acfr
iPX5400 | ETHERNET TRANSCEIVER PAGE 7
Summary of Features
Note:
The above specifications are correct at time of printing but subjected to changes without prior notice due to product
improvements.
Technical Specification
Low latency audio and data transceiver
RS485 and voice at full duplex ; music audio at simplex
IP Paging server / network switch not required
Supports automatic link crossover
Setup via browser, controlable via PMX software
Supports 3 modes ;
- Always On
- On on remote trigger or through API
- On on paging data ( transmits during paging, siren activation )
Power requirement :
Voltage
Current
Connectivity
- LAN interface
- Common protocols
- Communication protocols
Audio
- Analogue in/out (peak-to-peak)
- Total harmonic distortion (THD)
- S/N ratio (full scale signal)
- Conversion format
- Data
User interface
Case :
Dimension (WxHxD)
Weight
12 - 24V DC (Normal DC 24V)
<100 mA
RJ-45, 10/100T Base
TCP/IP, UDP, IGMP, HTTP
UDMP, ADP
100 x 147 x 40 mm
320 g
1.25V (line)
0.1%
83 dB
WAV PCM 48KHz 16 Bit ( Bidirectional & Half Duplex )
UART RS485 ( Bidirectional & Full Duplex )
IE Ver 9 and above, Firefox, Google Chrome (preferred)
Warranty Conditions
Disclaimer
AMPERES ELECTRONICS SDN BHD
MADE IN MALAYSIA
Published : NOVEMBER 2018
ISO 9001: 2008
Design & Manufacture of Public Address Equipment and Systems
Certicate No. 16895 / A / 0001 / UK / En
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes
Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn
Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor,
Malaysia or its authorized dealers. This warranty is not valid if repairs are performed by unauthorized
personnel or service centres.
This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as
well as removal and installation of the product from the main system are for the account of the purchaser.
This warranty shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using
the product with power supply voltage other than shown on the product, or any other power supply source /
adaptor not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not
directly related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use
of the unit; moreover the warranty does not cover any damages which may be caused to people and things
when using the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on
this certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 36 months from
the date of purchase or for a specified period in countries where this is stated by a national law. In this case,
the extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if
the design changes or improvements are made.
Information contained in this manual is subject to change without prior notice and does not represent a
commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss
or damages whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS
SDN BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in
conjunction with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages
caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by
the manufacturer.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Amperes iPX5400 User manual

Type
User manual

Amperes iPX5400 is a transceiver unit that works in duplex (paging) mode, connects in pairs, and communicates without full IP solutions. It's a simple device allowing peer-to-peer communication. It can reduce the risk of lightning surges by sending audio from a Guard House's paging mic to the main system through a fiber link, and avoid the need to lay new cables by transmitting audio or data rack-to-rack. It can also connect with a wireless AP in areas where new cables are impossible to lay.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI