GENMAX GM3300i User manual

Type
User manual

GENMAX GM3300i is a powerful and versatile inverter generator that can provide up to 3000 running watts and 3300 peak watts of electricity. It's perfect for providing backup power during outages or for powering tools and appliances at remote job sites. The GM3300i features a fuel-efficient engine that runs for up to 10.5 hours on a single tank of gas, and it's easy to start with a simple pull cord. It also has a number of safety features, including an overload alarm and a low oil alarm.

GENMAX GM3300i is a powerful and versatile inverter generator that can provide up to 3000 running watts and 3300 peak watts of electricity. It's perfect for providing backup power during outages or for powering tools and appliances at remote job sites. The GM3300i features a fuel-efficient engine that runs for up to 10.5 hours on a single tank of gas, and it's easy to start with a simple pull cord. It also has a number of safety features, including an overload alarm and a low oil alarm.

USER MANUAL
FOR MODELS:
GM2200i
Digital Inverter Generator
1800 Running Watts | 2200 Peak Watts
GM3200i
Digital Inverter Generator
2800 Running Watts | 3200 Peak Watts
GM3300i
Digital Inverter Generator
3000 Running Watts | 3300 Peak Watts
R
2
CHONGQING DINKING POWER MACHINERY CO., LTD
GM2200i 1800 2200 1.0 4500 79.7 48.6×43 0.09 10W30
GM3200i 2800 3200 1.0 4600 145 64×45 0.12 10W30
(Gel)
A5RTC
A5RTC
(Gel)
For portable generators where the neutral is floating, the operator's manual shall include the
following wording or equivalent:
The portable generator stator winding is isolated from the frame and from the AC receptacle
ground pin; and Electrical devices that require a connection between one conductor pin and the
grounded receptacle pin may not function properly.
NEUTRAL FLOATING
GM3300i 3000 3300 1.0 4600 145 64×45 0.12 10W30
A5RTC
3
LIMITED WARRANTY
Model Number: _____________________________________
Name: ___________________________________________
Serial Number: ______________________________________
Street Address: ___________________________________
Date Purchased: ____________________________________
Purchased From: ____________________________________
City, State, ZIP: ____________________________________
Country: __________________________________________
Phone Number: ___________________________________
E-Mail: ___________________________________________
WARRANTY CARD
1.
R
Email: [email protected] Phone: 866-960-2920
4
LIMITED WARRANTY
Warranty Card
GM2200i/3200i/3300i
GM2200i
GM3200i/3300i
GENMAX
GM2200i/3200i/3300i
5
Connection of the product to a building’s electrical
system is not applicable.
6
7
SAFETY LABELS AND DECALS GM2200i / GM3200i / GM3300i
RV30 Plug(1)
8
BASIC INVERTER FEATURES GM2200i / GM3200i / GM3300i
GM2200i
9
GM2200i
10
11
AC Breaker:
to block current.
Parallel Connectors:To increase AC power output,
the connector sockets are used to connect the two
same type generator with special paralleling cords.
The connector sockets is only used to the
communication between the inverters, they can not
used for AC power output.
The special paralleling cords shall be purchase
separately, and they shall be approved by
certification body.
10
11
12
12 CO Alarm: Flashing red light: dangerous levels of
carbon monoxide gas have built up leave
immediately until area has aired out. Move generator
to well-ventilated area before operation. Flashing
yellow light: carbon monoxide sensor malfunction.
Sensor needs service.
Output Indicator: Indicates the inverter is
ready to be used.
Overload Alarm: Indicates that the inverter is
overloaded.
Low Oil Alarm: Indicates low oil level.
10
GM3200i/GM3300i
10
11
AC Breaker:
to block current.
12 3RV30
3
Parallel Connectors:To increase AC power output,
the connector sockets are used to connect the two
same type generator with special paralleling cords.
The connector sockets is only used to the
communication between the inverters, they can not
used for AC power output.
The special paralleling cords shall be purchase
separately, and they shall be approved by
certification body.
12
11
4
10
13
13 CO Alarm : Flashing red light: dangerous levels of
carbon monoxide gas have built up leave
immediately until area has aired out. Move generator
to well-ventilated area before operation. Flashing
yellow light: carbon monoxide sensor malfunction.
Sensor needs service.
Output Indicator: Indicates the inverter is
ready to be used.
Overload Alarm: Indicates that the inverter is
overloaded.
Low Oil Alarm: Indicates low oil level.
11
GENMAX
12
GENMAX
GENMAX
GENMAX
13
14
15
Starting
16
.
17
18
19
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

GENMAX GM3300i User manual

Type
User manual

GENMAX GM3300i is a powerful and versatile inverter generator that can provide up to 3000 running watts and 3300 peak watts of electricity. It's perfect for providing backup power during outages or for powering tools and appliances at remote job sites. The GM3300i features a fuel-efficient engine that runs for up to 10.5 hours on a single tank of gas, and it's easy to start with a simple pull cord. It also has a number of safety features, including an overload alarm and a low oil alarm.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI