Thermaline boiling pans - h = 700 mm
Steam tilting boiling pans
Internet: http://www.electrolux.com/foodservice
DABA0402010-05-28Subject to change without notice
Supply voltage 230 V, 1N, 50/60 230 V, 1N, 50/60 230 V, 1N, 50/60 230 V, 1N, 50/60 230 V, 1N, 50/60
Net weight - kg. 170 230 270 360 390
auxiliary 0.2 0.2 0.2 0.2 0.2
Power - kW
relative dynamic pressure bar - min/max 1, 1.5 1, 1.5 1, 1.5 1, 1.5 1, 1.5
Steam supply
Steam consuption - kg/h 34 46 63 78 101
Heating type Direct Direct Direct Direct Direct
diameter 519 640 710 710 892
depth 360 395 465 587 580
Vessel dimensions - mm
Working temperature - min/max - °C 50, 126 50, 126 50, 126 50, 126 50, 126
Double jacketed lid ● ● ● ● ●
Tilting mechanism Automatic Automatic Automatic Automatic Automatic
Electronic ● ● ● ● ●
Net vessel useful capacity - Lt. 60 100 150 200 300
height 700 700 700 700 700
depth 900 900 900 1000 1000
width 1100 1200 1300 1300 1500
External dimensions - mm
Configuration Round; Tilting Round; Tilting Round; Tilting Round; Tilting Round; Tilting
pressure min. , max. - bar 2, 6 2, 6 2, 6 2, 6 2, 6
Water supply
TECHNICAL DATA
TBOT06SCFO
584437
TBOT10SCFO
584443
TBOT15SCFO
584452
TBOT20SCGO
584458
TBOT30SCGO
584467
• Error display for quick
trouble-shooting.
• A SOFT setting for a gentle heat
input, for delicate products -
avoiding undesired spillage.
• A HOLD setting to maintain
boiled food at a requested
temperature in order to avoid over
heating.
• Level of energy: from full power
in order to speed up the cooking
process or low power for gentle
simmering.
• On request it can be connected
to an HACCP integrated system
for monitoring, supervision and
recording of all data by means of a
computer.
• Prearranged for eventual energy
optimisation or external
surveillance systems.
Construction
• Internal frame and extenal
panels are in AISI 304 stainless
steel.
• AISI 316 stainless steel cooking
vessel and double jacket.
• The high-quality thermal
insulation of the pan saves energy
and keeps operating ambient
temperature low for the comfort of
the chefs.
• Safety valve avoids overpressure
of the steam in the jacket.
• An integrated water mixing tap is
available as an option.
Hygiene & Safety
• Minimised presence of narrow
gaps for easier cleaning of the
sides in order to meet the highest
hygiene standards.
• Discharge tube (available upon
request) is very easy to clean from
the outside.
• IPX6 water resistant.
• 98% recyclable by weight &
packing free of toxic substances.