Ss Brewtech Jacketed Tank Kit Operating instructions

Type
Operating instructions
ENGINEERING BETTER BEER
FTSs Touch │Jacketed Tank
Page 2
IN THE BOX
Check Valve Assembly
FTSs Touch Pump Harness Extension
1.5” TC Sleeved Thermowell Adapter Silicone Thermowell Cover
Hose Barbs
3/8” to 1/2” MPT
FTSs TOUCH | JACKETED TANK KIT
Hose Clamps
Page 3
SYSTEM OVERVIEW
The basic principle of the Fermentation Temperature Stabilization System (FTSs) is to pump chilled
glycol through the jacket of your vessel when the temperature of your wort is greater than the controller
set-point.
The FTSs is intended to be a low pressure closed loop system. Glycol pumped from the glycol chiller
to the fermenter is then returned to the glycol chiller to be used again.
INTRODUCTION
Warm Glycol Return
Cold Glycol Supply
Low Pressure
Closed Loop System
Page 4
ASSEMBLY INSTRUCTIONS
INSTALLING THE 1.5” TC SLEEVED THERMOWELL ADAPTER
1.5” TC Sleeved Thermowell
Adapter Location
1.5” TC Clamp
1.5” Sleeved Thermowell Adapter
Thermoprobe
Silicone Thermowell Cover
Silicone TC Gasket
Page 5
Next submerge the pump(s) in the glycol solution, and top off the reservoir to about the 90% full
level, making sure the evaporator coil is sufciently submerged. This will allow glycol to ow through
each fermenter’s jacket without risking the chance of owing back to the reservoir and overowing the
reservoir. Use the reservoir’s sight glass as an indicator for glycol level. Reinstall the reservoir lid, and
route the pump’s lead wire(s) through the notch when the evaporator coil enters the reservoir.
Pump
Glycol Chiller
Evaporator
Coil
Glycol Solution
at 90% Full Level
Silicone Tubing
Sight Glass
Lid
ASSEMBLY INSTRUCTIONS
Page 6
Supply Line- Extend a length of silicone tubing between the glycol chiller’s outlet barb and the hose
barb on the check valve at the tank (Fig. A). Be sure to install the tubing to the barb that corresponds to
the pump’s outlet. Secure each end of the tubing to the barbs using hose clamps.
Return Line- Extend a length of silicone tubing between the hose barb on the tank’s jacket outlet
(Fig. B) and the glycol chiller’s return barb. Secure each end of the tubing using hose clamps.
Note: If additional tubing is required to span the distance between the chiller and fermenter, you can
purchase more at www.ssbrewtech.com or pick some up at your local hardware store.
ASSEMBLY INSTRUCTIONS (CONTINUED)
FIG. B
RETURN LINE
SUPPLY LINE
FIG. A
Unitank Fitting
Unitank Fitting
Check Valve Assembly
Silicone
Check Valve
3/8” Hose Barb
to 1/2” MPT
*Note: Be sure to use Teon tape on any threaded ttings
3/8” Hose Barb
to 1/2” MPT
3/8” Silicone Tube
to Glycol Chiller
3/8” Silicone Tube
to Pump
3/8” Hose Clamp
3/8” Hose Clamp
REV 10172022
SsBrewtech.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Ss Brewtech Jacketed Tank Kit Operating instructions