INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
ODA1FRxx / ODA1FSxx / ODA1TRxx / ODA1TSxx
SAFETY
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• Allow 50mm above and around the fitting for air dissipation (do not cover the fitting with insulation)
• This product is for indoor use only
• This product is Class I and must be earthed
• This product is IP20 rated
INSTALLATION
• Provide power to the required point of installation
• Cut a suitable hole in the mounting surface as per the cut-out details (see Fig. 1) ensuring not to
infringe with any joists, gas/water pipes or electrical cables
Fig. 1
• Connect the luminaire to the mains supply ensuring the correct polarity is observed (see Fig. 2):
L – Live (brown), E – Earth (green/yellow), N – Neutral (blue). Two cables can be inserted into the
push-fit terminal block in order to achieve loop-in/loop-out wiring
Fig. 2
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
AMA1TSxx / AMA2TSxx / AMA3TSxx / AMA4TSxx
SAFETY
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• Allow 50mm above and around the fitting for air dissipation (do not cover the fitting with insulation)
• This product is for indoor use only
• This product is Class II double insulated
• This product is IP20 rated
INSTALLATION
• Provide power to the required point of installation
• Cut a suitable hole in the mounting surface as per the cut-out details (see Fig. 1) ensuring not to
infringe with any joists, gas/water pipes or electrical cables
Fig. 1
• Connect the luminaire to the mains supply ensuring the correct polarity is observed (see Fig. 2):
L – Live (brown), E – Earth (green/yellow), N – Neutral (blue). The earth terminal is non-functional and
only provided for convenience. Two cables can be inserted into the push-fit terminal block in order to
achieve loop-in/loop-out wiring
Fig. 2
Fig. 1
Fig. 2
• Connect the luminaire to the mains supply ensuring the correct polarity is observed (see Fig. 2):
L – Live (brown), E – Earth (green/yellow), N – Neutral (blue). Two cables can be inserted into the push-fit
terminal block in order to achieve loop-in / loop-out wiring